Dosimetric response of fabricated Ge-doped optical fibres in computed tomography RQT beam quality x-ray beams. (5th July 2019)
- Record Type:
- Journal Article
- Title:
- Dosimetric response of fabricated Ge-doped optical fibres in computed tomography RQT beam quality x-ray beams. (5th July 2019)
- Main Title:
- Dosimetric response of fabricated Ge-doped optical fibres in computed tomography RQT beam quality x-ray beams
- Authors:
- Rais, N N M
Bradley, D A
Hashim, A
Isa, N M
Osman, N D
Ismail, I
Hassan, H A
Noor, N M - Abstract:
- Abstract: Novel germanium (Ge)-doped silica glass fibres tailor-made in Malaysia are fast gaining recognition as potential media for thermoluminescence (TL) dosimetry, with active research ongoing into exploitation of their various beneficial characteristics. Investigation is made herein of the capability of these media for use in diagnostic imaging dosimetry, specifically at the radiation dose levels typically obtained in conduct of Computed Tomography (CT). As a first step within such efforts, there is need to investigate the performance of the fibres using tightly defined spectra, use being made of a Philips constant potential industrial x-ray facility, Model MG165, located at the Malaysian Nuclear Agency Secondary Standards Dosimetry Lab (SSDL). Standard radiation beam qualities (termed RQT) have been established for CT, in accord with IEC 61267: 2003 and IAEA Technical Reports Series No. 457: 2007. A calibrated ionisation chamber has also been utilised, forming a component part of the SSDL equipment. The fabricated fibres used in this study are 2.3 mol% flat fibre (FF) of dimensions 643 × 356 μ m 2 and 2.3 mol% cylindrical fibre (CF) of 481 μ m diameter, while the commercial fibre used is 4 mol% with core diameter of 50 μ m. The dopant concentrations are nominal preform values. The fibres have been irradiated to doses of 20, 30 and 40 milligray (mGy) for each of the beam qualities RQT 8, RQT 9 and RQT 10. For x-rays generated at constant potential values from 100 to 150Abstract: Novel germanium (Ge)-doped silica glass fibres tailor-made in Malaysia are fast gaining recognition as potential media for thermoluminescence (TL) dosimetry, with active research ongoing into exploitation of their various beneficial characteristics. Investigation is made herein of the capability of these media for use in diagnostic imaging dosimetry, specifically at the radiation dose levels typically obtained in conduct of Computed Tomography (CT). As a first step within such efforts, there is need to investigate the performance of the fibres using tightly defined spectra, use being made of a Philips constant potential industrial x-ray facility, Model MG165, located at the Malaysian Nuclear Agency Secondary Standards Dosimetry Lab (SSDL). Standard radiation beam qualities (termed RQT) have been established for CT, in accord with IEC 61267: 2003 and IAEA Technical Reports Series No. 457: 2007. A calibrated ionisation chamber has also been utilised, forming a component part of the SSDL equipment. The fabricated fibres used in this study are 2.3 mol% flat fibre (FF) of dimensions 643 × 356 μ m 2 and 2.3 mol% cylindrical fibre (CF) of 481 μ m diameter, while the commercial fibre used is 4 mol% with core diameter of 50 μ m. The dopant concentrations are nominal preform values. The fibres have been irradiated to doses of 20, 30 and 40 milligray (mGy) for each of the beam qualities RQT 8, RQT 9 and RQT 10. For x-rays generated at constant potential values from 100 to 150 kV, a discernible energy-dependent response is seen, comparisons being made with that of lithium fluoride (LiF) thermoluminescence dosimeters (TLD-100). TL yield versus dose has also been investigated for x-ray doses from 2 to 40 mGy, all exhibiting linearity. Compared to TLD-100, greater sensitivity is observed for the fibres. … (more)
- Is Part Of:
- Journal of radiological protection. Volume 39:Number 3(2019:Sep.)
- Journal:
- Journal of radiological protection
- Issue:
- Volume 39:Number 3(2019:Sep.)
- Issue Display:
- Volume 39, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 39
- Issue:
- 3
- Issue Sort Value:
- 2019-0039-0003-0000
- Page Start:
- N8
- Page End:
- N18
- Publication Date:
- 2019-07-05
- Subjects:
- fabricated Ge-doped silica -- TLD-100 -- RQT beam quality
Radiation -- Safety measures -- Periodicals
Health Physics -- Periodicals
Radiation Monitoring -- Periodicals
Radiation Protection -- Periodicals
Rayonnement -- Sécurité -- Mesures -- Périodiques
Electronic journals
Fulltext
Internet Resource
Periodical
363.179905 - Journal URLs:
- http://www.iop.org/EJ/journal/JRP ↗
http://iopscience.iop.org/0952-4746/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1361-6498/ab1c16 ↗
- Languages:
- English
- ISSNs:
- 0952-4746
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19573.xml