Impact of cardiac resynchronisation therapy on cardiologists' exposure to radiation during implantation of pacemakers and implantable cardioverter-defibrillators. (15th April 2019)
- Record Type:
- Journal Article
- Title:
- Impact of cardiac resynchronisation therapy on cardiologists' exposure to radiation during implantation of pacemakers and implantable cardioverter-defibrillators. (15th April 2019)
- Main Title:
- Impact of cardiac resynchronisation therapy on cardiologists' exposure to radiation during implantation of pacemakers and implantable cardioverter-defibrillators
- Authors:
- Daval, Charline
Faroux, Laurent
Lesaffre, François
Blanpain, Thierry
Chabert, Jean-Pierre
Martin, Angeline
Guinot, Mathias
Luconi, Nicolas
Espinosa, Madeline
Nazeyrollas, Pierre
Tourneux, Christophe
Metz, Damien - Abstract:
- Abstract: Cardiologists are among the health professionals that are most exposed to ionizing radiation, but there is no recent study quantifying overexposure of physicians during cardiac resynchronisation therapy (CRT) procedures compared to 'classical' implantation of pacemakers (PMs) or implantable cardioverter-defibrillators (ICDs). We aimed to measure and compare operator exposure to radiation during implantation of PM and ICD with or without CRT. The study population comprised all PMs and ICDs implanted in a large referral centre over a six months period. The endpoint was operator radiation exposure, assessed using a personal electronic dosimeter located on operator's chest. In total, 169 PM/ICD implantations were analysed, 19 of which included CRT. Compared with 'classical' implantation, cardiologist radiation exposure was 9-fold greater during CRT procedures (p < 0.001). Physician exposure was related to dose-area product (R 2 = 0.21 during 'classical' implantations and R 2 = 0.57 during CRT procedures). Our study shows that cardiologists' exposure to radiation during CRT implantation was 9-fold greater than during procedures without CRT.
- Is Part Of:
- Journal of radiological protection. Volume 39:Number 2(2019:Jun.)
- Journal:
- Journal of radiological protection
- Issue:
- Volume 39:Number 2(2019:Jun.)
- Issue Display:
- Volume 39, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 39
- Issue:
- 2
- Issue Sort Value:
- 2019-0039-0002-0000
- Page Start:
- 489
- Page End:
- 497
- Publication Date:
- 2019-04-15
- Subjects:
- pacemaker -- implantable cardioverter-defibrillator -- cardiac resynchronisation -- operator dosimetry
Radiation -- Safety measures -- Periodicals
Health Physics -- Periodicals
Radiation Monitoring -- Periodicals
Radiation Protection -- Periodicals
Rayonnement -- Sécurité -- Mesures -- Périodiques
Electronic journals
Fulltext
Internet Resource
Periodical
363.179905 - Journal URLs:
- http://www.iop.org/EJ/journal/JRP ↗
http://iopscience.iop.org/0952-4746/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1361-6498/ab1377 ↗
- Languages:
- English
- ISSNs:
- 0952-4746
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19569.xml