Assessment of left ventricular performance during percutaneous transluminal coronary angioplasty: a study by intravenous digital subtraction ventriculography. Issue 4 (April 1988)
- Record Type:
- Journal Article
- Title:
- Assessment of left ventricular performance during percutaneous transluminal coronary angioplasty: a study by intravenous digital subtraction ventriculography. Issue 4 (April 1988)
- Main Title:
- Assessment of left ventricular performance during percutaneous transluminal coronary angioplasty: a study by intravenous digital subtraction ventriculography.
- Authors:
- Norell, M S
Lyons, J P
Gershlick, A H
Gardener, J E
Rothman, M T
Layton, C A
Balcon, R - Abstract:
- Abstract : Left ventricular performance during percutaneous transluminal coronary angioplasty was assessed in 52 patients by intravenous digital subtraction ventriculography. After injection of contrast into the right atrium ventriculograms were obtained before and during balloon inflation. In 37 patients they were also obtained after the procedure. A 12 lead electrocardiogram was monitored throughout. During balloon inflation the left ventricular ejection fraction fell (from 73% to 57%) in all but one patient; the decreases in patients with single vessel or multivessel disease were similar. The fall in left ventricular ejection fraction during percutaneous transluminal coronary angioplasty of the left anterior descending artery (19%) was significantly greater than that during balloon inflation in the right coronary (10%) or circumflex (8%) coronary arteries. It also reduced anterobasal, anterior, and apical segmental shortening while right coronary percutaneous transluminal coronary angioplasty affected inferior and apical segments. In 33 (63%) patients the ST segment was altered during balloon inflation. The fall in left ventricular ejection fraction correlated significantly with the magnitude of both ST segment elevation (r = 0.637) and ST depression (r = 0.396). Left ventricular ejection fraction and regional wall motion returned to baseline values after the procedure. Balloon inflation during percutaneous transluminal coronary angioplasty produces considerableAbstract : Left ventricular performance during percutaneous transluminal coronary angioplasty was assessed in 52 patients by intravenous digital subtraction ventriculography. After injection of contrast into the right atrium ventriculograms were obtained before and during balloon inflation. In 37 patients they were also obtained after the procedure. A 12 lead electrocardiogram was monitored throughout. During balloon inflation the left ventricular ejection fraction fell (from 73% to 57%) in all but one patient; the decreases in patients with single vessel or multivessel disease were similar. The fall in left ventricular ejection fraction during percutaneous transluminal coronary angioplasty of the left anterior descending artery (19%) was significantly greater than that during balloon inflation in the right coronary (10%) or circumflex (8%) coronary arteries. It also reduced anterobasal, anterior, and apical segmental shortening while right coronary percutaneous transluminal coronary angioplasty affected inferior and apical segments. In 33 (63%) patients the ST segment was altered during balloon inflation. The fall in left ventricular ejection fraction correlated significantly with the magnitude of both ST segment elevation (r = 0.637) and ST depression (r = 0.396). Left ventricular ejection fraction and regional wall motion returned to baseline values after the procedure. Balloon inflation during percutaneous transluminal coronary angioplasty produces considerable abnormalities of global and regional left ventricular performance and this indicates the presence of myocardial ischaemia, which may not be apparent on electrocardiographic monitoring. Intravenous digital subtraction ventriculography is useful for monitoring left ventricular performance during controlled episodes of coronary occlusion produced by balloon inflation. … (more)
- Is Part Of:
- Heart. Volume 59:Issue 4(1988)
- Journal:
- Heart
- Issue:
- Volume 59:Issue 4(1988)
- Issue Display:
- Volume 59, Issue 4 (1988)
- Year:
- 1988
- Volume:
- 59
- Issue:
- 4
- Issue Sort Value:
- 1988-0059-0004-0000
- Page Start:
- 419
- Page End:
- 428
- Publication Date:
- 1988-04
- Subjects:
- Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/hrt.59.4.419 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19571.xml