Head-to-head comparison of quantitative measurements between intravascular imaging systems: An in vitro phantom study. (October 2021)
- Record Type:
- Journal Article
- Title:
- Head-to-head comparison of quantitative measurements between intravascular imaging systems: An in vitro phantom study. (October 2021)
- Main Title:
- Head-to-head comparison of quantitative measurements between intravascular imaging systems: An in vitro phantom study
- Authors:
- Nishi, Takeshi
Imura, Shinji
Kitahara, Hideki
Kobayashi, Yoshio
Yock, Paul G.
Fitzgerald, Peter J.
Honda, Yasuhiro - Abstract:
- Abstract: Introduction: The present study aimed to compare the accuracy of quantitative measurements by contemporary intravascular imaging systems including optical frequency domain imaging (OFDI), frequency domain optical coherence tomography (FD-OCT), and 6 intravascular ultrasound (IVUS) systems. Methods: We imaged five cylindrical phantom models made from an acrylic resin with known lumen diameters (1.51, 2.03, 3.04, 4.04, and 5.04 mm, respectively) using OFDI (FastView and LUNAWAVE, Terumo), FD-OCT (Dragonfly JP and ILUMIEN OPTIS, Abbott Vascular), and 6 mechanically rotating IVUS systems including a system, two 40-MHz, one 45-MHz, two 60-Mhz and one broad-band frequency IVUS systems. The OFDI, FD-OCT, and IVUS images were obtained using automated motorized pullback in a tank filled with 37-degree Celsius saline and, in cases of OFDI and FD-OCT, contrast-saline mixture (1:1 ratio) and contrast under the system setting of the refractive index for the corresponding flush medium. Results: All the imaging systems showed good accuracy and excellent precision of lumen measurement with the relative differences between the measured diameter and actual phantom diameter being ranging from −2.9% to 8.0% and minimum standard deviations of the measured diameters (≤0.02 mm). Conclusion: The present study demonstrated that contemporary intravascular imaging systems including OFDI, FD-OCT, and IVUS provided clinically acceptable accuracy and excellent precision of quantitative lumenAbstract: Introduction: The present study aimed to compare the accuracy of quantitative measurements by contemporary intravascular imaging systems including optical frequency domain imaging (OFDI), frequency domain optical coherence tomography (FD-OCT), and 6 intravascular ultrasound (IVUS) systems. Methods: We imaged five cylindrical phantom models made from an acrylic resin with known lumen diameters (1.51, 2.03, 3.04, 4.04, and 5.04 mm, respectively) using OFDI (FastView and LUNAWAVE, Terumo), FD-OCT (Dragonfly JP and ILUMIEN OPTIS, Abbott Vascular), and 6 mechanically rotating IVUS systems including a system, two 40-MHz, one 45-MHz, two 60-Mhz and one broad-band frequency IVUS systems. The OFDI, FD-OCT, and IVUS images were obtained using automated motorized pullback in a tank filled with 37-degree Celsius saline and, in cases of OFDI and FD-OCT, contrast-saline mixture (1:1 ratio) and contrast under the system setting of the refractive index for the corresponding flush medium. Results: All the imaging systems showed good accuracy and excellent precision of lumen measurement with the relative differences between the measured diameter and actual phantom diameter being ranging from −2.9% to 8.0% and minimum standard deviations of the measured diameters (≤0.02 mm). Conclusion: The present study demonstrated that contemporary intravascular imaging systems including OFDI, FD-OCT, and IVUS provided clinically acceptable accuracy and excellent precision of quantitative lumen measurement in phantom models in vitro across a wide range of dimensions. Future research to confirm these findings in vivo are warranted. … (more)
- Is Part Of:
- IJC heart & vasculature. Volume 36(2021)
- Journal:
- IJC heart & vasculature
- Issue:
- Volume 36(2021)
- Issue Display:
- Volume 36, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 36
- Issue:
- 2021
- Issue Sort Value:
- 2021-0036-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10
- Subjects:
- Intravascular ultrasound -- Optical coherence tomography
Cardiovascular system -- Diseases -- Periodicals
Cardiovascular system -- Pathophysiology -- Periodicals
616.1005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23529067/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.ijcha.2021.100867 ↗
- Languages:
- English
- ISSNs:
- 2352-9067
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19549.xml