Dose calculation validation of a convolution algorithm in a solid water phantom. (September 2021)
- Record Type:
- Journal Article
- Title:
- Dose calculation validation of a convolution algorithm in a solid water phantom. (September 2021)
- Main Title:
- Dose calculation validation of a convolution algorithm in a solid water phantom
- Authors:
- Dubus, François
Reynaert, Nick - Abstract:
- Highlights: Dose calculation algorithms using electron density. Dose accuracy in solid water phantom. Appropriate CT calibration curve. Dose calculation agreement with CT calibration correction. Abstract: Purpose: The dose calculated using a convolution algorithm should be validated in a simple homogeneous water-equivalent phantom before clinical use. The dose calculation accuracy within a solid water phantom was investigated. Methods: The specific Gamma knife design requires a dose rate calibration within a spherical solid water phantom. The TMR10 algorithm, which approximates the phantom material as liquid water, correctly computes the absolute dose in water. The convolution algorithm, which considers electron density miscalculates the dose in water as the phantom Hounsfield units were converted into higher electron density when the original CT calibration curve was used. To address this issue, the electron density of liquid water was affected by modifying the CT calibration curve. The absolute dose calculated using the convolution algorithm was compared with that computed by the TMR10. The measured depth dose profiles were also compared to those computed by the convolution and TMR10 algorithms. A patient treatment was recalculated in the solid-water phantom and the delivery quality assurance was checked. Results: The convolution algorithm and the TMR10 calculate an absolute dose within 1% when using the modified CT calibration curve. The dose depth profile calculatedHighlights: Dose calculation algorithms using electron density. Dose accuracy in solid water phantom. Appropriate CT calibration curve. Dose calculation agreement with CT calibration correction. Abstract: Purpose: The dose calculated using a convolution algorithm should be validated in a simple homogeneous water-equivalent phantom before clinical use. The dose calculation accuracy within a solid water phantom was investigated. Methods: The specific Gamma knife design requires a dose rate calibration within a spherical solid water phantom. The TMR10 algorithm, which approximates the phantom material as liquid water, correctly computes the absolute dose in water. The convolution algorithm, which considers electron density miscalculates the dose in water as the phantom Hounsfield units were converted into higher electron density when the original CT calibration curve was used. To address this issue, the electron density of liquid water was affected by modifying the CT calibration curve. The absolute dose calculated using the convolution algorithm was compared with that computed by the TMR10. The measured depth dose profiles were also compared to those computed by the convolution and TMR10 algorithms. A patient treatment was recalculated in the solid-water phantom and the delivery quality assurance was checked. Results: The convolution algorithm and the TMR10 calculate an absolute dose within 1% when using the modified CT calibration curve. The dose depth profile calculated using the convolution algorithms was superimposed on the TMR10 and measured dose profiles when the modified CT calibration curve was applied. The Gamma index was better than 93%. Conclusions: Dose calculation algorithms, which consider electron density, require a CT calibration curve adapted to the phantom material to correctly compute the dose in water. … (more)
- Is Part Of:
- Physica medica. Volume 89(2021)
- Journal:
- Physica medica
- Issue:
- Volume 89(2021)
- Issue Display:
- Volume 89, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 89
- Issue:
- 2021
- Issue Sort Value:
- 2021-0089-2021-0000
- Page Start:
- 193
- Page End:
- 199
- Publication Date:
- 2021-09
- Subjects:
- CT calibration curve -- Electron density -- Solid water phantom -- Dose calculation algorithm
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2021.08.003 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19561.xml