Comparing sensitivity and specificity of pacemaker ID application and cardiac rhythm management device-finder application in identifying cardiac implantable electronic device manufacturer using chest radiograph – An observational study. (September 2021)
- Record Type:
- Journal Article
- Title:
- Comparing sensitivity and specificity of pacemaker ID application and cardiac rhythm management device-finder application in identifying cardiac implantable electronic device manufacturer using chest radiograph – An observational study. (September 2021)
- Main Title:
- Comparing sensitivity and specificity of pacemaker ID application and cardiac rhythm management device-finder application in identifying cardiac implantable electronic device manufacturer using chest radiograph – An observational study
- Authors:
- Shams, Pirbhat
Mehdi, Muhammad
Ali, Jamshed
Ahmed, Intisar
Saadia, Sheema
Iqbal, Sameen
Hameed Khan, Aamir
Saeed, Yawer - Abstract:
- Abstract: Background: Smartphone-based applications to identify cardiac implantable electronic devices (CIED) are extremely useful in circumstances, where urgent device interrogation is needed, and a device identification card is not available. Few studies have provided insights regarding the utility of these applications. We have studied two widely available applications i.e., Pacemaker ID app (PMIDa) or Cardiac Rhythm Management Device-Finder (CRMD-f) to identify device manufacturers in CIEDs. Methods: 547 patients who underwent CIED implantation from the year 2016–2020 in our institute were enrolled. There were 438 Medtronic and 109 St. Jude's devices. All chest radiographs were de-identified and resized into 225*225 pixels focusing on the CIED. PMIDa and CRMD-f applications were used to identify the CIED. Accuracy, sensitivity, specificity, negative predictive value, and positive predictive value for both applications were calculated and compared. Results: Overall, CRMD-f application has higher specificity (93.58 vs. 82.5%) but lower sensitivity (53.6 vs. 55%) than PMIDa. The accuracy of both applications was comparable (61.6% vs. 60.5%). Accuracy varied with CIED model and type tested, and radiograph projection used. Accuracy is greatest with Cardiac-Resynchronization-Therapy (CRT) devices for both applications, followed by a single lead pacemaker. Conclusion: CRMD-f has higher accuracy and specificity for CIED manufacturer identification. Both PMIDa and CRMD-f areAbstract: Background: Smartphone-based applications to identify cardiac implantable electronic devices (CIED) are extremely useful in circumstances, where urgent device interrogation is needed, and a device identification card is not available. Few studies have provided insights regarding the utility of these applications. We have studied two widely available applications i.e., Pacemaker ID app (PMIDa) or Cardiac Rhythm Management Device-Finder (CRMD-f) to identify device manufacturers in CIEDs. Methods: 547 patients who underwent CIED implantation from the year 2016–2020 in our institute were enrolled. There were 438 Medtronic and 109 St. Jude's devices. All chest radiographs were de-identified and resized into 225*225 pixels focusing on the CIED. PMIDa and CRMD-f applications were used to identify the CIED. Accuracy, sensitivity, specificity, negative predictive value, and positive predictive value for both applications were calculated and compared. Results: Overall, CRMD-f application has higher specificity (93.58 vs. 82.5%) but lower sensitivity (53.6 vs. 55%) than PMIDa. The accuracy of both applications was comparable (61.6% vs. 60.5%). Accuracy varied with CIED model and type tested, and radiograph projection used. Accuracy is greatest with Cardiac-Resynchronization-Therapy (CRT) devices for both applications, followed by a single lead pacemaker. Conclusion: CRMD-f has higher accuracy and specificity for CIED manufacturer identification. Both PMIDa and CRMD-f are specific tools to identify CIED but have low sensitivity. Highlights: Both PMIDa and CRMD-f are specific tools to identify CIED but have low sensitivity. Algorithms used to identify CIED exhibit variability in accuracies across different studies. Artificial intelligence is gaining attraction in clinical cardiac electrophysiology due to ease of use and quicker results. Further studies are needed to ensure prognostic benefit of AI use in clinical management of patients with CIED. … (more)
- Is Part Of:
- Annals of medicine and surgery. Volume 69(2021)
- Journal:
- Annals of medicine and surgery
- Issue:
- Volume 69(2021)
- Issue Display:
- Volume 69, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 69
- Issue:
- 2021
- Issue Sort Value:
- 2021-0069-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-09
- Subjects:
- Arrhythmias -- CIED interrogation -- Cardia-X -- Pacemaker -- Device identity
Surgery -- Periodicals
Medicine -- Periodicals
General Surgery -- Periodicals
Education, Medical -- Periodicals
Periodicals
617 - Journal URLs:
- http://www.sciencedirect.com/science/journal/20490801 ↗
http://bibpurl.oclc.org/web/73795 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/20490801 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/20490801 ↗
http://www.annalsjournal.com/home ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.amsu.2021.102741 ↗
- Languages:
- English
- ISSNs:
- 2049-0801
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19561.xml