Study protocol for a randomised controlled trial: harmonising optimal strategy for treatment of coronary artery stenosis — coronary intervention with next-generation drug-eluting stent platforms and abbreviated dual antiplatelet therapy (HOST-IDEA) trial. Issue 10 (11th October 2017)
- Record Type:
- Journal Article
- Title:
- Study protocol for a randomised controlled trial: harmonising optimal strategy for treatment of coronary artery stenosis — coronary intervention with next-generation drug-eluting stent platforms and abbreviated dual antiplatelet therapy (HOST-IDEA) trial. Issue 10 (11th October 2017)
- Main Title:
- Study protocol for a randomised controlled trial: harmonising optimal strategy for treatment of coronary artery stenosis — coronary intervention with next-generation drug-eluting stent platforms and abbreviated dual antiplatelet therapy (HOST-IDEA) trial
- Authors:
- Kim, Chi-Hoon
Han, Jung-Kyu
Yang, Han-Mo
Park, Kyung Woo
Lee, Hae-Young
Kang, Hyun-Jae
Koo, Bon-Kwon
Lee, Namho
Cha, Tae-Joon
Yang, Tae-Hyun
Jeong, Myung-Ho
Yoon, Myeong-Ho
Lee, Seung Uk
Lee, Seung Jin
Kim, Jin Won
Cho, Jin-Man
Han, Kyu-Rock
Pyun, Wook Bum
Kim, Hyo-Soo - Abstract:
- Abstract : Introduction: We have recently seen the introduction of newer generation drug-eluting stents with ultrathin struts that use advanced polymer technologies. However, the efficacy and safety of these newest stents have not yet been fully explored. In addition, there are still controversies over the optimal duration of dual antiplatelet therapy (DAPT) after stent implantation, particularly for ultrathin stents with the newest polymer technologies. Methods and analysis: The HOST-IDEA trial is a randomised, open-label, multicentre, non-inferiority trial and the first study to directly compare two of these ultrathin sirolimus-eluting stents: Orsiro stent with biodegradable polymer, and polymer-free Coroflex ISAR (CX-ISAR) stent. This study has a scheme of 2×2 factorial design according to the stent type and DAPT duration (3 vs 12 months). A total of 2152 patients will be randomised and stratified to demonstrate the non-inferiority of CX-ISAR to Orsiro, or of the abbreviated DAPT duration to the conventional 12 months (both in 1:1 ratio). For the comparison of stent type, the primary endpoint is target lesion failure (TLF), which is a composite of cardiac death, target vessel-related myocardial infarction and clinically driven target lesion revascularisation. For the comparison of DAPT duration, the net adverse clinical event is the coprimary endpoint, which is defined as a composite of TLF, definite/probable stent thrombosis and major bleeding. Ethic approval andAbstract : Introduction: We have recently seen the introduction of newer generation drug-eluting stents with ultrathin struts that use advanced polymer technologies. However, the efficacy and safety of these newest stents have not yet been fully explored. In addition, there are still controversies over the optimal duration of dual antiplatelet therapy (DAPT) after stent implantation, particularly for ultrathin stents with the newest polymer technologies. Methods and analysis: The HOST-IDEA trial is a randomised, open-label, multicentre, non-inferiority trial and the first study to directly compare two of these ultrathin sirolimus-eluting stents: Orsiro stent with biodegradable polymer, and polymer-free Coroflex ISAR (CX-ISAR) stent. This study has a scheme of 2×2 factorial design according to the stent type and DAPT duration (3 vs 12 months). A total of 2152 patients will be randomised and stratified to demonstrate the non-inferiority of CX-ISAR to Orsiro, or of the abbreviated DAPT duration to the conventional 12 months (both in 1:1 ratio). For the comparison of stent type, the primary endpoint is target lesion failure (TLF), which is a composite of cardiac death, target vessel-related myocardial infarction and clinically driven target lesion revascularisation. For the comparison of DAPT duration, the net adverse clinical event is the coprimary endpoint, which is defined as a composite of TLF, definite/probable stent thrombosis and major bleeding. Ethic approval and dissemination: All the institutions involved in this study are required to have ethical approval prior to patient enrolment. This multicentre study will recruit patients through competitive registration, but institutions that have not yet obtained ethical approvals have made it impossible to enrol patients in a centralised web database. The final results will be presented at relevant international conferences and will be materialised in the form of papers. Trial registration number: NCT02601157 ; Pre-results. … (more)
- Is Part Of:
- BMJ open. Volume 7:Issue 10(2017)
- Journal:
- BMJ open
- Issue:
- Volume 7:Issue 10(2017)
- Issue Display:
- Volume 7, Issue 10 (2017)
- Year:
- 2017
- Volume:
- 7
- Issue:
- 10
- Issue Sort Value:
- 2017-0007-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-10-11
- Subjects:
- stent -- polymer -- antiplatelet therapy
Medicine -- Research -- Periodicals
610.72 - Journal URLs:
- http://www.bmj.com/archive ↗
http://bmjopen.bmj.com/ ↗ - DOI:
- 10.1136/bmjopen-2017-016617 ↗
- Languages:
- English
- ISSNs:
- 2044-6055
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19511.xml