Comparing 14-day adhesive patch with 24-h Holter monitoring. (May 2014)
- Record Type:
- Journal Article
- Title:
- Comparing 14-day adhesive patch with 24-h Holter monitoring. (May 2014)
- Main Title:
- Comparing 14-day adhesive patch with 24-h Holter monitoring
- Authors:
- Cheung, Christopher C
Kerr, Charles R
Krahn, Andrew D - Abstract:
- Evaluation of: : Barrett PM, Komatireddy R, Haaser S et al. Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring. Am. J. Med. 127(1), 95.e11–95.e17 (2014). The investigation of cardiac arrhythmias in the outpatient ambulatory setting has traditionally been initiated with the Holter monitor. Using the continuous recording over 24 or 48 h, the Holter monitor permits the detection of baseline rhythm, dysrhythmia and conduction abnormalities, including heart block and changes in the ST segment that may indicate myocardial ischemia. However, apart from the bulkiness and inconvenience of the device itself, the lack of extended monitoring results in a diagnostic yield of typically less than 20%. In this study by Barrett et al., 146 patients referred for the evaluation of cardiac arrhythmia were prospectively enrolled to wear both the 24-h Holter monitor and 14-day adhesive patch monitor (Zio ® Patch) simultaneously. The primary outcome was the detection of any one of six arrhythmias: supraventricular tachycardia, atrial fibrillation/flutter, pause >3 s, atrioventricular block, ventricular tachycardia, or polymorphic ventricular tachycardia/fibrillation. The adhesive patch monitor detected more arrhythmia events compared with the Holter monitor over the total wear time (96 vs 61 events; p < 0.001), although the Holter monitor detected more events during the initial 24-h monitoring period (61 vs 52 events; p = 0.013). Novel,Evaluation of: : Barrett PM, Komatireddy R, Haaser S et al. Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring. Am. J. Med. 127(1), 95.e11–95.e17 (2014). The investigation of cardiac arrhythmias in the outpatient ambulatory setting has traditionally been initiated with the Holter monitor. Using the continuous recording over 24 or 48 h, the Holter monitor permits the detection of baseline rhythm, dysrhythmia and conduction abnormalities, including heart block and changes in the ST segment that may indicate myocardial ischemia. However, apart from the bulkiness and inconvenience of the device itself, the lack of extended monitoring results in a diagnostic yield of typically less than 20%. In this study by Barrett et al., 146 patients referred for the evaluation of cardiac arrhythmia were prospectively enrolled to wear both the 24-h Holter monitor and 14-day adhesive patch monitor (Zio ® Patch) simultaneously. The primary outcome was the detection of any one of six arrhythmias: supraventricular tachycardia, atrial fibrillation/flutter, pause >3 s, atrioventricular block, ventricular tachycardia, or polymorphic ventricular tachycardia/fibrillation. The adhesive patch monitor detected more arrhythmia events compared with the Holter monitor over the total wear time (96 vs 61 events; p < 0.001), although the Holter monitor detected more events during the initial 24-h monitoring period (61 vs 52 events; p = 0.013). Novel, single-lead, intermediate-duration, user-friendly adhesive patch monitoring devices, such as the Zio Patch, represent the changing face of ambulatory ECG monitoring. However, the loss of quality, automated rhythm analysis and inability to detect myocardial ischemia continue to remain important issues that will need to be addressed prior to the implementation of these new devices. … (more)
- Is Part Of:
- Future cardiology. Volume 10:Number 3(2014)
- Journal:
- Future cardiology
- Issue:
- Volume 10:Number 3(2014)
- Issue Display:
- Volume 10, Issue 3 (2014)
- Year:
- 2014
- Volume:
- 10
- Issue:
- 3
- Issue Sort Value:
- 2014-0010-0003-0000
- Page Start:
- 319
- Page End:
- 322
- Publication Date:
- 2014-05
- Subjects:
- adhesive patch monitor -- arrhythmia -- Holter monitor -- Zio Patch
Cardiology -- Research -- Periodicals
616.12005 - Journal URLs:
- http://www.futuremedicine.com/loi/fca ↗
http://www.futuremedicine.com/ ↗ - DOI:
- 10.2217/fca.14.24 ↗
- Languages:
- English
- ISSNs:
- 1479-6678
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4060.521300
British Library DSC - BLDSS-3PM
British Library HMNTS - Digital store
British Library HMNTS - ELD Digital store - Ingest File:
- 19480.xml