Transcatheter Closure of Perimembranous Ventricular Septal Defect Using the Lifetech Konar-Multi Functional Occluder: Early to Midterm Results of the Indonesian Multicenter Study. Issue 1 (24th February 2022)
- Record Type:
- Journal Article
- Title:
- Transcatheter Closure of Perimembranous Ventricular Septal Defect Using the Lifetech Konar-Multi Functional Occluder: Early to Midterm Results of the Indonesian Multicenter Study. Issue 1 (24th February 2022)
- Main Title:
- Transcatheter Closure of Perimembranous Ventricular Septal Defect Using the Lifetech Konar-Multi Functional Occluder: Early to Midterm Results of the Indonesian Multicenter Study
- Authors:
- Kuswiyanto, Rahmat Budi
Gunawijaya, Eka
Djer, Mulyadi M.
Noormanto,
Rahman, Mahrus A.
Murni, Indah K.
Sukardi, Rubiana
Utamayasa, Alit
Ardiansyah, Rizky
Nova, Ria
Liliyanti, Sri
Rahayuningsih, Sri E.
Anggriawan, Shirley L.
Rahayuningsih, Tri Yanti
Koentartiwi, Dyahris
Soewarniaty, Renny
Yantie, Venny Kartika
Nugroho, Sasmito
Hidayat, Taufiq
Ontoseno, Teddy
Tobing, Tina C.
Ali, Muhamad
Bashari, Muhammad Hasan
Yosy, Denny S.
Arafuri, Nadya
Hilmanto, Dany
Yanuarso, Piprim B.
Advani, Najib
Sastroasmoro, Sudigdo
Putra, Sukman Tulus - Abstract:
- Background: The alternative device to close perimembranous ventricular septal defect (pmVSD) has been searched for better result, less complications and applicable for infants. However, the ideal device is still unavailable. We aimed to evaluate the effectiveness and outcome of transcatheter pmVSD closure using the KONAR-multi functional occluder (MFO). Methods: Clinical, procedural, follow-up data of pmVSD patients with symptom of heart failure or evidence of significant left to right shunt, growth failure, recurrent respiratory tract infection, and history of endocarditis who underwent transcatheter closure using the MFO were prospectively evaluated. Results: Between January 2016 and December 2017, there were complete records of 132 pmVSD children closed using MFO from eleven centers in Indonesia. The median of age was 4.5 (0.3–17.4) years; weight 14.8 (3.5–57) kg, defect size at the smallest part 3.4 (1.0–8.1) mm, flow ratio 1.6 (1.3–4.9), mean pulmonary artery pressure 18 (7–79) mmHg, fluoroscopy time 18 (3.8–91) and procedural time 75 (26–290) minutes. A retrograde approach was done in 41 (31%) patients. Procedures succeeded in first attempt in 126 (95.4%), failed in three and migration in three patients. Six of eight infants with congestive heart failure were closed successfully. Of 126 patients with successful VSD closure, 12 months follow-up were completed in all patients. The rate of complete occlusion at 1 month, 3 months, 6 months and 12 months after interventionBackground: The alternative device to close perimembranous ventricular septal defect (pmVSD) has been searched for better result, less complications and applicable for infants. However, the ideal device is still unavailable. We aimed to evaluate the effectiveness and outcome of transcatheter pmVSD closure using the KONAR-multi functional occluder (MFO). Methods: Clinical, procedural, follow-up data of pmVSD patients with symptom of heart failure or evidence of significant left to right shunt, growth failure, recurrent respiratory tract infection, and history of endocarditis who underwent transcatheter closure using the MFO were prospectively evaluated. Results: Between January 2016 and December 2017, there were complete records of 132 pmVSD children closed using MFO from eleven centers in Indonesia. The median of age was 4.5 (0.3–17.4) years; weight 14.8 (3.5–57) kg, defect size at the smallest part 3.4 (1.0–8.1) mm, flow ratio 1.6 (1.3–4.9), mean pulmonary artery pressure 18 (7–79) mmHg, fluoroscopy time 18 (3.8–91) and procedural time 75 (26–290) minutes. A retrograde approach was done in 41 (31%) patients. Procedures succeeded in first attempt in 126 (95.4%), failed in three and migration in three patients. Six of eight infants with congestive heart failure were closed successfully. Of 126 patients with successful VSD closure, 12 months follow-up were completed in all patients. The rate of complete occlusion at 1 month, 3 months, 6 months and 12 months after intervention were 95.2%, 97.6%, 99.2%, and 99.2%, respectively. New-onset aortic regurgitation and moderate tricuspid regurgitation developed only in five and three patients. Neither complete atrioventricular block, nor other complications occurred. Conclusion: Transcatheter closure of pmVSD using the MFO is safe, effective, and feasible in infants and children. … (more)
- Is Part Of:
- Global heart. Volume 17:Issue 1(2022)
- Journal:
- Global heart
- Issue:
- Volume 17:Issue 1(2022)
- Issue Display:
- Volume 17, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 17
- Issue:
- 1
- Issue Sort Value:
- 2022-0017-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-02-24
- Subjects:
- Perimembranous ventricular septal defect -- transcatheter closure -- KONAR-multi functional occluder
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
Cardiovascular system -- Diseases -- Prevention -- Periodicals
Cardiovascular system -- Diseases -- Treatment -- Periodicals
Cardiovascular system -- Diseases -- Prevention
Cardiovascular Diseases -- prevention & control -- Periodicals
Cardiovascular Diseases -- Periodicals
Developing Countries -- Periodicals
Electronic journals
Electronic journals
Periodicals
616.1005 - Journal URLs:
- https://globalheartjournal.com/ ↗
https://www.world-heart-federation.org/global-heart/ ↗
http://www.sciencedirect.com/science/journal/22118160 ↗ - DOI:
- 10.5334/gh.1106 ↗
- Languages:
- English
- ISSNs:
- 2211-8160
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 19477.xml