An Activatable NIR‐II Nanoprobe for In Vivo Early Real‐Time Diagnosis of Traumatic Brain Injury. (19th November 2019)
- Record Type:
- Journal Article
- Title:
- An Activatable NIR‐II Nanoprobe for In Vivo Early Real‐Time Diagnosis of Traumatic Brain Injury. (19th November 2019)
- Main Title:
- An Activatable NIR‐II Nanoprobe for In Vivo Early Real‐Time Diagnosis of Traumatic Brain Injury
- Authors:
- Li, Chunyan
Li, Wanfei
Liu, Huanhuan
Zhang, Yejun
Chen, Guangcun
Li, Zijing
Wang, Qiangbin - Abstract:
- Abstract: Traumatic brain injury (TBI) is one of the most dangerous acute diseases resulting in high morbidity and mortality. Current methods remain limited with respect to early diagnosis and real‐time feedback on the pathological process. Herein, a targeted activatable fluorescent nanoprobe (V&A@Ag2 S) in the second near‐infrared window (NIR‐II) is presented for in vivo optical imaging of TBI. Initially, the fluorescence of V&A@Ag2 S is turned off owing to energy transfer from Ag2 S to the A1094 chromophore. Upon intravenous injection, V&A@Ag2 S quickly accumulates in the inflamed vascular endothelium of TBI based on VCAM1‐mediated endocytosis, after which the nanoprobe achieves rapid recovery of the NIR‐II fluorescence of Ag2 S quantum dots (QDs) owing to the bleaching of A1094 by the prodromal biomarker of TBI, peroxynitrite (ONOO − ). The nanoprobe offers high specificity, rapid response, and high sensitivity toward ONOO −, providing a convenient approach for in vivo early real‐time assessment of TBI. Abstract : TBI TBD : Eine gezielt aktivierbare NIR‐II‐Nanosonde (V&A@Ag2 S) wird vorgestellt, die speziell Regionen mit traumatischen Hirnverletzungen (TBI) illuminiert. Das System basiert auf der durch den prodromalen Biomarker Peroxynitrit (ONOO − ) getriggerten Fluoreszenzregeneration und ermöglicht die frühe Echtzeiterfassung von TBI in vivo.
- Is Part Of:
- Angewandte Chemie. Volume 132:Number 1(2020)
- Journal:
- Angewandte Chemie
- Issue:
- Volume 132:Number 1(2020)
- Issue Display:
- Volume 132, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 132
- Issue:
- 1
- Issue Sort Value:
- 2020-0132-0001-0000
- Page Start:
- 253
- Page End:
- 258
- Publication Date:
- 2019-11-19
- Subjects:
- Biologische Bildgebung -- Fluoreszenzsonden -- Peroxynitrit -- NIR-II -- Traumatische Hirnverletzung
Chemistry -- Periodicals
540 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/ange.201911803 ↗
- Languages:
- English
- ISSNs:
- 0044-8249
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0902.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19446.xml