Non-invasive positive-pressure ventilation with positive end-expiratory pressure counteracts inward air leaks during preoxygenation: a randomised crossover controlled study in healthy volunteers. (April 2018)
- Record Type:
- Journal Article
- Title:
- Non-invasive positive-pressure ventilation with positive end-expiratory pressure counteracts inward air leaks during preoxygenation: a randomised crossover controlled study in healthy volunteers. (April 2018)
- Main Title:
- Non-invasive positive-pressure ventilation with positive end-expiratory pressure counteracts inward air leaks during preoxygenation: a randomised crossover controlled study in healthy volunteers
- Authors:
- Hanouz, J.-L.
Le Gall, F.
Gérard, J.-L.
Terzi, N.
Normand, H. - Abstract:
- Abstract: Background: During preoxygenation, the lack of tight fit between the mask and the patient's face results in inward air leak preventing effective preoxygenation. We hypothesized that non-invasive positive-pressure ventilation and positive end-expiratory pressure (PEEP) could counteract inward air leak. Methods: Healthy volunteers were randomly assigned to preoxygenated through spontaneous breathing without leak (SB), spontaneous breathing with a calibrated air leak (T-shaped piece between the mouth and the breathing system; SB-leak), or non-invasive positive inspiratory pressure ventilation (inspiratory support +6 cm H2 O; PEEP +5 cm H2 O) with calibrated leak (PPV-leak). The volunteers breathed through a mouthpiece connected to an anaesthesia ventilator. The expired oxygen fraction (FeO2 ) and air-leak flow (ml s −1 ) were measured. The primary end point was the proportion of volunteers with FeO2 >90% at 3 min. The secondary end points were FeO2 at 3 min, time to reach FeO2 of 90%, and the inspiratory air-leak flow. Results: Twenty healthy volunteers were included. The proportion of volunteers with FeO2 >90% at 3 min was 0% in the SB-leak group, 95% in the SB group, and 100% in the PPV-leak group ( P <0.001). At 3 min, the mean [standard deviation (sd )] FeO2 was 89 (1)%, 76 (1)%, and 90 (0)% in the SB, SB-leak, and PPV-leak groups, respectively ( P <0.001). The mean (sd ) inward air leak was 59 (12) ml s −1 in the SB-leak group, but 0 (0) ml s −1 in the PPV-leakAbstract: Background: During preoxygenation, the lack of tight fit between the mask and the patient's face results in inward air leak preventing effective preoxygenation. We hypothesized that non-invasive positive-pressure ventilation and positive end-expiratory pressure (PEEP) could counteract inward air leak. Methods: Healthy volunteers were randomly assigned to preoxygenated through spontaneous breathing without leak (SB), spontaneous breathing with a calibrated air leak (T-shaped piece between the mouth and the breathing system; SB-leak), or non-invasive positive inspiratory pressure ventilation (inspiratory support +6 cm H2 O; PEEP +5 cm H2 O) with calibrated leak (PPV-leak). The volunteers breathed through a mouthpiece connected to an anaesthesia ventilator. The expired oxygen fraction (FeO2 ) and air-leak flow (ml s −1 ) were measured. The primary end point was the proportion of volunteers with FeO2 >90% at 3 min. The secondary end points were FeO2 at 3 min, time to reach FeO2 of 90%, and the inspiratory air-leak flow. Results: Twenty healthy volunteers were included. The proportion of volunteers with FeO2 >90% at 3 min was 0% in the SB-leak group, 95% in the SB group, and 100% in the PPV-leak group ( P <0.001). At 3 min, the mean [standard deviation (sd )] FeO2 was 89 (1)%, 76 (1)%, and 90 (0)% in the SB, SB-leak, and PPV-leak groups, respectively ( P <0.001). The mean (sd ) inward air leak was 59 (12) ml s −1 in the SB-leak group, but 0 (0) ml s −1 in the PPV-leak group ( P <0.001). Conclusions: Preoxygenation through non-invasive positive-pressure ventilation and PEEP provided effective preoxygenation despite an inward air leak. Clinical trial registration: NCT03087825 . … (more)
- Is Part Of:
- British journal of anaesthesia. Volume 120:Number 4(2018)
- Journal:
- British journal of anaesthesia
- Issue:
- Volume 120:Number 4(2018)
- Issue Display:
- Volume 120, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 120
- Issue:
- 4
- Issue Sort Value:
- 2018-0120-0004-0000
- Page Start:
- 868
- Page End:
- 873
- Publication Date:
- 2018-04
- Subjects:
- airway management -- anaesthesia -- general -- non-invasive ventilation -- positive-pressure respiration
Anesthesiology -- Periodicals
Anesthesia -- Periodicals
617.9605 - Journal URLs:
- http://bja.oupjournals.org ↗
http://bja.oxfordjournals.org ↗
https://www.journals.elsevier.com/british-journal-of-anaesthesia ↗
http://ukcatalogue.oup.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1016/j.bja.2017.12.002 ↗
- Languages:
- English
- ISSNs:
- 0007-0912
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2303.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19439.xml