Diagnostic accuracy of haemoglobin colour strip (HCS-HLL), a digital haemoglobinometer (TrueHb) and a non-invasive device (TouchHb) for screening patients with anaemia. Issue 2 (14th August 2015)
- Record Type:
- Journal Article
- Title:
- Diagnostic accuracy of haemoglobin colour strip (HCS-HLL), a digital haemoglobinometer (TrueHb) and a non-invasive device (TouchHb) for screening patients with anaemia. Issue 2 (14th August 2015)
- Main Title:
- Diagnostic accuracy of haemoglobin colour strip (HCS-HLL), a digital haemoglobinometer (TrueHb) and a non-invasive device (TouchHb) for screening patients with anaemia
- Authors:
- Neogi, Sutapa Bandyopadhyay
Negandhi, Himanshu
Kar, Rakhee
Bhattacharya, Maitrayee
Sen, Rajeev
Varma, Neelam
Bharti, Priyanka
Sharma, Jyoti
Bhushan, Himanshu
Zodpey, Sanjay
Saxena, Renu - Abstract:
- Abstract : Aim: Estimation of haemoglobin (Hb) remains a challenge, particularly in outreach settings. There is a need to have a simple and cost-effective device to detect anaemia. Three devices (haemoglobin colour scale (HCS)-HLL (Hindustan Lifecare Limited), TrueHb V.1.1, TouchHb Alpha 1.1- non-invasive) have been developed in India recently. This study aimed to determine the diagnostic accuracy of these tests (index) for the screening of anaemia against haematological autoanalyzer (reference). Methods: The study was conducted in four medical colleges of India. All consenting adult patients (>18 years of age) undergoing routine investigations were included. Each patient underwent the reference test and at least one index test. Outcome assessors for the index tests were blinded to the results of the reference test. Diagnostic accuracy was calculated using cut-offs proposed by WHO. Results: A total of 5244 patients underwent the reference test while HCS-HLL, TrueHb and TouchHb tests were conducted on 2745, 2331 and 2874 patients respectively. The positive likelihood ratio of HCS-HLL using capillary blood (1.2), venous blood (1.7) and TouchHb (1.5) was lower than TrueHb capillary (3.7; 95% CI 3.3 to 4.2) and venous blood (5.7; 95% CI 4.9 to 6.6). TrueHb had a sensitivity of 74.4% (95% CI 71.9% to 76.8%) for venous and 82.0% (95% CI 79.8% to 89.2%) for capillary samples. The specificity was high (>75.0%). The area under receiver operating characteristic was close to 80.0%.Abstract : Aim: Estimation of haemoglobin (Hb) remains a challenge, particularly in outreach settings. There is a need to have a simple and cost-effective device to detect anaemia. Three devices (haemoglobin colour scale (HCS)-HLL (Hindustan Lifecare Limited), TrueHb V.1.1, TouchHb Alpha 1.1- non-invasive) have been developed in India recently. This study aimed to determine the diagnostic accuracy of these tests (index) for the screening of anaemia against haematological autoanalyzer (reference). Methods: The study was conducted in four medical colleges of India. All consenting adult patients (>18 years of age) undergoing routine investigations were included. Each patient underwent the reference test and at least one index test. Outcome assessors for the index tests were blinded to the results of the reference test. Diagnostic accuracy was calculated using cut-offs proposed by WHO. Results: A total of 5244 patients underwent the reference test while HCS-HLL, TrueHb and TouchHb tests were conducted on 2745, 2331 and 2874 patients respectively. The positive likelihood ratio of HCS-HLL using capillary blood (1.2), venous blood (1.7) and TouchHb (1.5) was lower than TrueHb capillary (3.7; 95% CI 3.3 to 4.2) and venous blood (5.7; 95% CI 4.9 to 6.6). TrueHb had a sensitivity of 74.4% (95% CI 71.9% to 76.8%) for venous and 82.0% (95% CI 79.8% to 89.2%) for capillary samples. The specificity was high (>75.0%). The area under receiver operating characteristic was close to 80.0%. Consistent results were seen for detection of severe anaemia. Conclusions: The digital method (TrueHb) emerged as a better diagnostic method for screening anaemia. Its effectiveness should be established in outreach settings before further recommendation. … (more)
- Is Part Of:
- Journal of clinical pathology. Volume 69:Issue 2(2016)
- Journal:
- Journal of clinical pathology
- Issue:
- Volume 69:Issue 2(2016)
- Issue Display:
- Volume 69, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 69
- Issue:
- 2
- Issue Sort Value:
- 2016-0069-0002-0000
- Page Start:
- 164
- Page End:
- 170
- Publication Date:
- 2015-08-14
- Subjects:
- diagnostic screening -- DIAGNOSTICS -- HAEMATOLOGY
Pathology -- Periodicals
Pathology, Molecular -- Periodicals
616.0705 - Journal URLs:
- http://jcp.bmjjournals.com ↗
http://jcp.bmjjournals.com/content/by/year ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=162&action=archive ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/jclinpath-2015-203135 ↗
- Languages:
- English
- ISSNs:
- 0021-9746
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19419.xml