P1.10 Oral fluid based rapid syphilis testing. (8th July 2017)
- Record Type:
- Journal Article
- Title:
- P1.10 Oral fluid based rapid syphilis testing. (8th July 2017)
- Main Title:
- P1.10 Oral fluid based rapid syphilis testing
- Authors:
- Shannon, Chelsea
Bristow, CC
Cortina, SM Herbst De
Chang, JJ
Klausner, JD - Abstract:
- Abstract : Introduction: Point-of-care syphilis testing currently uses fingerstick blood to identify Treponema pallidum (TP) antibodies by qualitative immunoassay. However, oral fluid testing is highly preferred by patients. We aimed to determine if rapid tests intended for whole blood could be used to detect treponemal antibody in oral fluid. Methods: Oral fluid was collected at the UCLA Care Clinic from 49 participants using Oasis SuperSAL (Vancouver, WA). The device uses an absorbent cylindrical pad to collect and filter ~1 mL of oral fluid. Oral fluid filtrate was evaluated with 3 rapid syphilis tests: SD Bioline Syphilis 3.0 (SD), MedMira Reveal TP (MM), and First Response Anti-TP (FR) following manufacturer directions for whole blood. Reference test results, TP particle agglutination (TPPA) and rapid plasma reagin (RPR), were extracted from participants' medical records. We used 3 different definitions as a reference standard. Definition 1: TPPA reactive. Definition 2: TPPA and RPR reactive. Definition 3: TPPA reactive and RPR titer >1:4. Specimens nonreactive on both the TPPA and RPR were considered negative. We calculated specificity and sensitivity for each definition, and used the exact binomial method to determine 95% confidence intervals (CI). Results: With definitions 1, 2 and 3 respectively, SD sensitivity was 86.4% (CI: 65.1, 97.1), 93% (CI: 66.1, 99.8), 100% (CI: 59.0, 100); MM sensitivity was 6.3% (CI: 0.2, 30.2), 9.1% (CI: 0.2, 41.2), 16.7% (CI: 0.4, 64.1);Abstract : Introduction: Point-of-care syphilis testing currently uses fingerstick blood to identify Treponema pallidum (TP) antibodies by qualitative immunoassay. However, oral fluid testing is highly preferred by patients. We aimed to determine if rapid tests intended for whole blood could be used to detect treponemal antibody in oral fluid. Methods: Oral fluid was collected at the UCLA Care Clinic from 49 participants using Oasis SuperSAL (Vancouver, WA). The device uses an absorbent cylindrical pad to collect and filter ~1 mL of oral fluid. Oral fluid filtrate was evaluated with 3 rapid syphilis tests: SD Bioline Syphilis 3.0 (SD), MedMira Reveal TP (MM), and First Response Anti-TP (FR) following manufacturer directions for whole blood. Reference test results, TP particle agglutination (TPPA) and rapid plasma reagin (RPR), were extracted from participants' medical records. We used 3 different definitions as a reference standard. Definition 1: TPPA reactive. Definition 2: TPPA and RPR reactive. Definition 3: TPPA reactive and RPR titer >1:4. Specimens nonreactive on both the TPPA and RPR were considered negative. We calculated specificity and sensitivity for each definition, and used the exact binomial method to determine 95% confidence intervals (CI). Results: With definitions 1, 2 and 3 respectively, SD sensitivity was 86.4% (CI: 65.1, 97.1), 93% (CI: 66.1, 99.8), 100% (CI: 59.0, 100); MM sensitivity was 6.3% (CI: 0.2, 30.2), 9.1% (CI: 0.2, 41.2), 16.7% (CI: 0.4, 64.1); and FR sensitivity was 25% (CI: 8.7, 49.1), 25% (CI: 5.5, 57.2), 14.3% (CI: 0.4, 57.9). SD specificity was 56% (CI: 36.5, 75.5), MM specificity was 100% (CI: 35.9, 99.6) and FR specificity was 100% (CI: 83.9, 100). Conclusion: The high sensitivity of the SD test suggests a strong potential for oral fluid-based rapid syphilis testing. SD sensitivity increased with RPR titer. False positive results may be associated with the presence of non-venereal treponemal antibodies in oral fluid. The MM and FR tests had low sensitivity, perhaps due to differences in treponemal targets. Further research and development are needed. … (more)
- Is Part Of:
- Sexually transmitted infections. Volume 93(2017)Supplement 2
- Journal:
- Sexually transmitted infections
- Issue:
- Volume 93(2017)Supplement 2
- Issue Display:
- Volume 93, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 93
- Issue:
- 2
- Issue Sort Value:
- 2017-0093-0002-0000
- Page Start:
- A47
- Page End:
- A47
- Publication Date:
- 2017-07-08
- Subjects:
- Sexually transmitted diseases -- Periodicals
HIV infections -- Periodicals
616.951005 - Journal URLs:
- http://sti.bmj.com/ ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/176/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/sextrans-2017-053264.118 ↗
- Languages:
- English
- ISSNs:
- 1368-4973
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19407.xml