Application of an automatic segmentation method for evaluating cardiac structure doses received by breast radiotherapy patients. (July 2021)
- Record Type:
- Journal Article
- Title:
- Application of an automatic segmentation method for evaluating cardiac structure doses received by breast radiotherapy patients. (July 2021)
- Main Title:
- Application of an automatic segmentation method for evaluating cardiac structure doses received by breast radiotherapy patients
- Authors:
- Jung, Jae Won
Mille, Matthew M.
Ky, Bonnie
Kenworthy, Walter
Lee, Choonik
Yeom, Yeon Soo
Kwag, Aaron
Bosch, Walter
MacDonald, Shannon
Cahlon, Oren
Bekelman, Justin E.
Lee, Choonsik - Abstract:
- Highlights: Atlas-based method for contouring heart substructures on breast radiotherapy CT. Excellent agreement between automatic and manual contours for most patients. Dice similarity coefficient for LAD was low (0.06) because a narrow, long structure. Doses derived from automatic and manual contours agree within observer variability. For left breast treatment, right ventricle and LAD dose most senstive to contour shift. Abstract: Background and purpose: Quantifying radiation dose to cardiac substructures is important for research on the etiology and prevention of complications following radiotherapy; however, segmentation of substructures is challenging. In this study we demonstrate the application of our atlas-based automatic segmentation method to breast cancer radiotherapy plans for generating radiation doses in support of late effects research. Material and methods: We applied our segmentation method to contour heart substructures on the computed tomography (CT) images of 70 breast cancer patients who received external photon radiotherapy. Two cardiologists provided manual segmentation of the whole heart (WH), left/right atria, left/right ventricles, and left anterior descending artery (LAD). The automatically contours were compared with manual delineations to evaluate similarity in terms of geometry and dose. Results: The mean Dice similarity coefficient between manual and automatic segmentations was 0.96 for the WH, 0.65 to 0.82 for the atria and ventricles, andHighlights: Atlas-based method for contouring heart substructures on breast radiotherapy CT. Excellent agreement between automatic and manual contours for most patients. Dice similarity coefficient for LAD was low (0.06) because a narrow, long structure. Doses derived from automatic and manual contours agree within observer variability. For left breast treatment, right ventricle and LAD dose most senstive to contour shift. Abstract: Background and purpose: Quantifying radiation dose to cardiac substructures is important for research on the etiology and prevention of complications following radiotherapy; however, segmentation of substructures is challenging. In this study we demonstrate the application of our atlas-based automatic segmentation method to breast cancer radiotherapy plans for generating radiation doses in support of late effects research. Material and methods: We applied our segmentation method to contour heart substructures on the computed tomography (CT) images of 70 breast cancer patients who received external photon radiotherapy. Two cardiologists provided manual segmentation of the whole heart (WH), left/right atria, left/right ventricles, and left anterior descending artery (LAD). The automatically contours were compared with manual delineations to evaluate similarity in terms of geometry and dose. Results: The mean Dice similarity coefficient between manual and automatic segmentations was 0.96 for the WH, 0.65 to 0.82 for the atria and ventricles, and 0.06 for the LAD. The mean average surface distance was 1.2 mm for the WH, 3.4 to 4.1 mm for the atria and ventricles, and 6.4 mm for the LAD. We found the dose to the cardiac substructures based on our automatic segmentation agrees with manual segmentation within expected observer variability. For left breast patients, the mean absolute difference in mean dose was 0.1 Gy for the WH, 0.2 to 0.7 Gy for the atria and ventricles, and 1.8 Gy for the LAD. For right breast patients, these values were 0.0 Gy, 0.1 to 0.4 Gy, and 0.4 Gy, respectively. Conclusion: Our automatic segmentation method will facilitate the development of radiotherapy prescriptive criteria for mitigating cardiovascular complications. … (more)
- Is Part Of:
- Physics and imaging in radiation oncology. Volume 19(2021)
- Journal:
- Physics and imaging in radiation oncology
- Issue:
- Volume 19(2021)
- Issue Display:
- Volume 19, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 19
- Issue:
- 2021
- Issue Sort Value:
- 2021-0019-2021-0000
- Page Start:
- 138
- Page End:
- 144
- Publication Date:
- 2021-07
- Subjects:
- Cardiac structures -- Automatic segmentation -- Breast cancer -- Radiotherapy -- Late effects
Radiotherapy -- Periodicals
Radiation dosimetry -- Periodicals
Cancer -- Imaging -- Periodicals
Oncology -- Periodicals
615.842 - Journal URLs:
- http://www.sciencedirect.com/ ↗
https://www.journals.elsevier.com/physics-and-imaging-in-radiation-oncology/ ↗ - DOI:
- 10.1016/j.phro.2021.08.005 ↗
- Languages:
- English
- ISSNs:
- 2405-6316
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19414.xml