Comparison of 90Y SIRT predicted and delivered absorbed doses using a PSF conversion method. (September 2021)
- Record Type:
- Journal Article
- Title:
- Comparison of 90Y SIRT predicted and delivered absorbed doses using a PSF conversion method. (September 2021)
- Main Title:
- Comparison of 90Y SIRT predicted and delivered absorbed doses using a PSF conversion method
- Authors:
- Craig, Allison J.
Murray, Iain
Denis-Bacelar, Ana M.
Rojas, Bruno
Gear, Jonathan I.
Hossen, Lucy
Maenhout, Annelies
Khan, Nasir
Flux, Glenn D. - Abstract:
- Highlights: The resolution conversion method allowed comparison of 99m Tc and 90 Y imaging. 99m Tc pre-therapy imaging was predictive of the 90 Y absorbed dose to normal liver. 99m Tc pre-therapy imaging had poor predictability for tumours smaller than 100 cm 3 . Abstract: Purpose: The aims of this study were to develop and apply a method to correct for the differences in partial volume effects of pre-therapy Technetium-99 m ( 99m Tc)-MAA SPECT and post-therapy Yttrium-90 ( 90 Y) bremsstrahlung SPECT imaging in selective internal radiation therapy, and to use this method to improve quantitative comparison of predicted and delivered 90 Y absorbed doses. Methods: The spatial resolution of 99m Tc SPECT data was converted to that of 90 Y SPECT data using a function calculated from 99m Tc and 90 Y point spread functions. This resolution conversion method (RCM) was first applied to 99m Tc and 90 Y SPECT phantom data to validate the method, and then to clinical data to assess the power of 99m Tc SPECT imaging to predict the therapeutic absorbed dose. Results: The maximum difference between absorbed doses to phantom spheres was 178%. This was reduced to 27% after the RCM was applied. The clinical data demonstrated differences within 38% for mean absorbed doses delivered to the normal liver, which were reduced to 20% after application of the RCM. Analysis of clinical data showed that therapeutic absorbed doses delivered to tumours greater than 100 cm 3 were predicted to within 52%,Highlights: The resolution conversion method allowed comparison of 99m Tc and 90 Y imaging. 99m Tc pre-therapy imaging was predictive of the 90 Y absorbed dose to normal liver. 99m Tc pre-therapy imaging had poor predictability for tumours smaller than 100 cm 3 . Abstract: Purpose: The aims of this study were to develop and apply a method to correct for the differences in partial volume effects of pre-therapy Technetium-99 m ( 99m Tc)-MAA SPECT and post-therapy Yttrium-90 ( 90 Y) bremsstrahlung SPECT imaging in selective internal radiation therapy, and to use this method to improve quantitative comparison of predicted and delivered 90 Y absorbed doses. Methods: The spatial resolution of 99m Tc SPECT data was converted to that of 90 Y SPECT data using a function calculated from 99m Tc and 90 Y point spread functions. This resolution conversion method (RCM) was first applied to 99m Tc and 90 Y SPECT phantom data to validate the method, and then to clinical data to assess the power of 99m Tc SPECT imaging to predict the therapeutic absorbed dose. Results: The maximum difference between absorbed doses to phantom spheres was 178%. This was reduced to 27% after the RCM was applied. The clinical data demonstrated differences within 38% for mean absorbed doses delivered to the normal liver, which were reduced to 20% after application of the RCM. Analysis of clinical data showed that therapeutic absorbed doses delivered to tumours greater than 100 cm 3 were predicted to within 52%, although there were differences of up to 210% for smaller tumours, even after the RCM was applied. Conclusions: The RCM was successfully verified using phantom data. Analysis of the clinical data established that the 99m Tc pre-therapy imaging was predictive of the 90 Y absorbed dose to the normal liver to within 20%, but had poor predictability for tumours smaller than 100 cm 3 . … (more)
- Is Part Of:
- Physica medica. Volume 89(2021)
- Journal:
- Physica medica
- Issue:
- Volume 89(2021)
- Issue Display:
- Volume 89, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 89
- Issue:
- 2021
- Issue Sort Value:
- 2021-0089-2021-0000
- Page Start:
- 1
- Page End:
- 10
- Publication Date:
- 2021-09
- Subjects:
- Radioembolisation -- Y-90 -- SIRT -- Liver -- Dosimetry -- Microspheres
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2021.07.026 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19408.xml