Microwave‐Assisted Extraction for Quantification of Microplastics Using Pyrolysis–Gas Chromatography/Mass Spectrometry. (9th September 2021)
- Record Type:
- Journal Article
- Title:
- Microwave‐Assisted Extraction for Quantification of Microplastics Using Pyrolysis–Gas Chromatography/Mass Spectrometry. (9th September 2021)
- Main Title:
- Microwave‐Assisted Extraction for Quantification of Microplastics Using Pyrolysis–Gas Chromatography/Mass Spectrometry
- Authors:
- Hermabessiere, Ludovic
Rochman, Chelsea M. - Abstract:
- Abstract: Microplastics are now recognized as a persistent and global pollutant. To quantitively measure microplastics in environmental matrices, several techniques are used including new methods using pyrolysis–gas chromatography/mass spectrometry (Py–GC/MS). In the present study, a new extraction method using microwave‐assisted extraction (MAE) combined with Py–GC/MS was developed to extract and quantify a wide range of plastic polymers, and the method was validated using different environmental matrices. This new extraction method was able to extract polyethylene, polystyrene, polypropylene, poly(methyl‐methacrylate) (PMMA), polyvinylchloride (PVC), and polycarbonate in dichloromethane with good recoveries (92.9–119.7%). The limit of detection and limit of quantification (LOQ) of the method ranged from 0.002 to 0.18 µg and from 1.2 to 5.8 µg, respectively. Intra‐ and interday repeatability values with coefficients of variation less than 25% for all polymers were obtained. Method validation also included a spike and recovery using all polymers from clean water, dirty water, and shrimp and salmon fillet samples, with recoveries of 85 to 111, 87 to 138, 81 to 122, and 50 to 151%, respectively. Finally, the method was tested on unspiked wild mussels and bottled water for proof‐of‐concept. Both polyethylene and PVC were detected and quantified in mussels, and polycarbonate and polypropylene were detected below the LOQ. For bottled water, polypropylene, polystyrene, andAbstract: Microplastics are now recognized as a persistent and global pollutant. To quantitively measure microplastics in environmental matrices, several techniques are used including new methods using pyrolysis–gas chromatography/mass spectrometry (Py–GC/MS). In the present study, a new extraction method using microwave‐assisted extraction (MAE) combined with Py–GC/MS was developed to extract and quantify a wide range of plastic polymers, and the method was validated using different environmental matrices. This new extraction method was able to extract polyethylene, polystyrene, polypropylene, poly(methyl‐methacrylate) (PMMA), polyvinylchloride (PVC), and polycarbonate in dichloromethane with good recoveries (92.9–119.7%). The limit of detection and limit of quantification (LOQ) of the method ranged from 0.002 to 0.18 µg and from 1.2 to 5.8 µg, respectively. Intra‐ and interday repeatability values with coefficients of variation less than 25% for all polymers were obtained. Method validation also included a spike and recovery using all polymers from clean water, dirty water, and shrimp and salmon fillet samples, with recoveries of 85 to 111, 87 to 138, 81 to 122, and 50 to 151%, respectively. Finally, the method was tested on unspiked wild mussels and bottled water for proof‐of‐concept. Both polyethylene and PVC were detected and quantified in mussels, and polycarbonate and polypropylene were detected below the LOQ. For bottled water, polypropylene, polystyrene, and polycarbonate were all detected below the LOQ. We introduce a method combining MAE and Py–GC/MS as a tool for mass quantification of microplastics. This method can be used as a stand‐alone, or as a complementary method to spectroscopic techniques. Environ Toxicol Chem 2021;40:2733–2741. © 2021 SETAC Abstract : Microwave‐assisted extraction (MAE) of microplastics and their analysis by pyrolysis–gas chromatography/mass spectrometry (Py–GC/MS). Sample extraction and analysis are done at the same time as external calibration curves, allowing the quantification of six polymer types in various sample matrices. PE = polyethylene. … (more)
- Is Part Of:
- Environmental toxicology and chemistry. Volume 40:Number 10(2021)
- Journal:
- Environmental toxicology and chemistry
- Issue:
- Volume 40:Number 10(2021)
- Issue Display:
- Volume 40, Issue 10 (2021)
- Year:
- 2021
- Volume:
- 40
- Issue:
- 10
- Issue Sort Value:
- 2021-0040-0010-0000
- Page Start:
- 2733
- Page End:
- 2741
- Publication Date:
- 2021-09-09
- Subjects:
- Microplastic -- Contaminant of emerging concern -- Environmental chemistry -- Quantification -- Method -- Pyrolysis–gas chromatography/mass spectrometry
Pollution -- Environmental aspects -- Periodicals
Environmental chemistry -- Periodicals
615.902 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1552-8618 ↗
http://www.setacjournals.org/perlserv/?request=get-archive&issn=1552-8618 ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1002/etc.5179 ↗
- Languages:
- English
- ISSNs:
- 0730-7268
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3791.785000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19368.xml