Magnetic molecularly imprinted polymers for extraction of S‐phenylmercapturic acid from urine samples followed by high‐performance liquid chromatography. Issue 11 (25th August 2021)
- Record Type:
- Journal Article
- Title:
- Magnetic molecularly imprinted polymers for extraction of S‐phenylmercapturic acid from urine samples followed by high‐performance liquid chromatography. Issue 11 (25th August 2021)
- Main Title:
- Magnetic molecularly imprinted polymers for extraction of S‐phenylmercapturic acid from urine samples followed by high‐performance liquid chromatography
- Authors:
- Ye, Haipeng
Shao, Ji
Shi, Yanpeng
Tan, Siwei
Su, Kewen
Zhang, Ling
Shan, Xiaoyue - Abstract:
- Abstract: In this study, magnetic molecularly imprinted polymers (MMIPs) were prepared and used as sorbents for extraction of S‐phenylmercapturic acid (S‐PMA) from urine samples, followed by high‐performance liquid chromatography ultraviolet‐visible (HPLC‐UV/Vis) analysis. The MMIPs were synthesized by the copolymerization reaction of (phenylthio) acetic acid (template molecule), methacrylic acid (functional monomers) and ethylene glycol dimethacrylate (cross‐linkers). The morphology, structure property and surface groups of the prepared MMIPs were characterized by scan electron microscopy, transmission electron microscopy, infrared spectroscopy, X‐ray diffraction pattern, thermogravimetric analyses, Brunauer‐Emmett‐Teller and vibrating sample magnetometer. The selectivity of the MMIPs was investigated in the presence of interferents. Various parameters affecting the S‐PMA extraction efficiency were investigated, including MMIPs amount, pH, sample volume, desorption solvent, as well as extraction and desorption time. The obtained optimal parameters were as follows: MMIPs amount (20 mg), pH (3.0), sample volume (5 mL), desorption solvent (methanol/acetic acid [9/1, v/v]), extraction time (30 minutes) and desorption time (2 minutes). The method was validated according to the Food and Drug Administration Guidance for Industry on Bioanalytical Method Validation. The calibration curve for the analyte was linear in the concentration range of 0.030‐1.0 mg/L ( r = 0.9995). The LODAbstract: In this study, magnetic molecularly imprinted polymers (MMIPs) were prepared and used as sorbents for extraction of S‐phenylmercapturic acid (S‐PMA) from urine samples, followed by high‐performance liquid chromatography ultraviolet‐visible (HPLC‐UV/Vis) analysis. The MMIPs were synthesized by the copolymerization reaction of (phenylthio) acetic acid (template molecule), methacrylic acid (functional monomers) and ethylene glycol dimethacrylate (cross‐linkers). The morphology, structure property and surface groups of the prepared MMIPs were characterized by scan electron microscopy, transmission electron microscopy, infrared spectroscopy, X‐ray diffraction pattern, thermogravimetric analyses, Brunauer‐Emmett‐Teller and vibrating sample magnetometer. The selectivity of the MMIPs was investigated in the presence of interferents. Various parameters affecting the S‐PMA extraction efficiency were investigated, including MMIPs amount, pH, sample volume, desorption solvent, as well as extraction and desorption time. The obtained optimal parameters were as follows: MMIPs amount (20 mg), pH (3.0), sample volume (5 mL), desorption solvent (methanol/acetic acid [9/1, v/v]), extraction time (30 minutes) and desorption time (2 minutes). The method was validated according to the Food and Drug Administration Guidance for Industry on Bioanalytical Method Validation. The calibration curve for the analyte was linear in the concentration range of 0.030‐1.0 mg/L ( r = 0.9995). The LOD and LOQ of the method were 0.0080 and 0.0267 mg/L, respectively. The enrichment factor of the MMIPs was 5. The relative standard deviations of intra‐ and inter‐day tests were in the range of 3.8‐5.1% and 3.9‐6.3%, respectively. The recoveries at three different concentrations of 0.10, 0.50 and 0.80 mg/L ranged between 95.2% and 98.6%. In addition, the MMIPs could be reused for at least eight times. The proposed method was successfully applied to the determination of S‐PMA in urine samples. In addition, this developed method could be used as a tool in the early screening and clinical diagnosis of benzene intoxication. Abstract : Magnetic molecularly imprinted polymers (MMIPs) were prepared and used as sorbents for extraction of S‐phenylmercapturic acid (S‐PMA) from urine samples, followed by HPLC‐UV analysis. The MMIPs could be reused for at least eight times. The proposed method was successfully applied to the determination of S‐PMA in urine samples and indicated great potential for being an effective analytical tool in the early screening and clinical diagnosis of benzene intoxication. … (more)
- Is Part Of:
- Journal of molecular recognition. Volume 34:Issue 11(2021)
- Journal:
- Journal of molecular recognition
- Issue:
- Volume 34:Issue 11(2021)
- Issue Display:
- Volume 34, Issue 11 (2021)
- Year:
- 2021
- Volume:
- 34
- Issue:
- 11
- Issue Sort Value:
- 2021-0034-0011-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2021-08-25
- Subjects:
- human urine -- high‐performance liquid chromatography -- magnetic molecularly imprinted polymers -- solid‐phase extraction -- S‐phenylmercapturic acid
Molecular recognition -- Periodicals
Models, Molecular -- Periodicals
Molecular Conformation -- Periodicals
Molecular Sequence Data -- Periodicals
Molecular Structure -- Periodicals
Carrier Proteins -- Periodicals
572.8 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jmr.2930 ↗
- Languages:
- English
- ISSNs:
- 0952-3499
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5020.725000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19373.xml