Specific responses of canopy conductance to environmental factors in a coniferous plantation in subtropical China. (November 2021)
- Record Type:
- Journal Article
- Title:
- Specific responses of canopy conductance to environmental factors in a coniferous plantation in subtropical China. (November 2021)
- Main Title:
- Specific responses of canopy conductance to environmental factors in a coniferous plantation in subtropical China
- Authors:
- Xu, Mingjie
Hu, Jie
Zhang, Tao
Wang, Huimin
Zhu, Xianjin
Wang, Jianlei
Yang, Fengting
Zhang, Hui
Wang, Qianyu - Abstract:
- Highlights: Canopy conductance (gc) was primarily affected by vapor pressure deficit (VPD). Gc increased with net radiation following a logistic growth model. Deep soil water regulated gc under water and temperature stress conditions. Specific responses of gc in different climatic years should be noted. Abstract: Understanding the responses of canopy conductance (gc) to environmental factors would help ecologists to obtain further insight into the carbon and water exchange processes and forecast future changes in ecosystems under global climate change. Therefore, we investigated the seasonal and interannual variations in the gc based on 12 years of flux data that were observed by an eddy covariance system in a subtropical coniferous forest. Furthermore, by teasing out the dominant factors step by step, the specific gc responses to environmental factors were clarified, and the divergent responses in contrasting climatic years were determined. The multiyear mean gc was 3.46 ± 0.36 mm·s −1, and the gc peaked in April and declined to a minimum in October in most years. The vapor pressure deficit (VPD) was the most important factor that inhibited the gc, and the gc decreased sharply when the VPDs were greater than 1.8 kPa. Without high VPD stress, the gc increased linearly with air temperature (Ta) when the Ta was below 27 °C, after which it decreased. When the high VPD and Ta stresses were excluded, the gc increased with the net radiation (Rn) following a logistic growth model.Highlights: Canopy conductance (gc) was primarily affected by vapor pressure deficit (VPD). Gc increased with net radiation following a logistic growth model. Deep soil water regulated gc under water and temperature stress conditions. Specific responses of gc in different climatic years should be noted. Abstract: Understanding the responses of canopy conductance (gc) to environmental factors would help ecologists to obtain further insight into the carbon and water exchange processes and forecast future changes in ecosystems under global climate change. Therefore, we investigated the seasonal and interannual variations in the gc based on 12 years of flux data that were observed by an eddy covariance system in a subtropical coniferous forest. Furthermore, by teasing out the dominant factors step by step, the specific gc responses to environmental factors were clarified, and the divergent responses in contrasting climatic years were determined. The multiyear mean gc was 3.46 ± 0.36 mm·s −1, and the gc peaked in April and declined to a minimum in October in most years. The vapor pressure deficit (VPD) was the most important factor that inhibited the gc, and the gc decreased sharply when the VPDs were greater than 1.8 kPa. Without high VPD stress, the gc increased linearly with air temperature (Ta) when the Ta was below 27 °C, after which it decreased. When the high VPD and Ta stresses were excluded, the gc increased with the net radiation (Rn) following a logistic growth model. The gc increased logarithmically with the soil water content at 5 cm depth (SWC5). The effects of the soil water content at 50 cm depth (SWC50) emerged under water stress or temperature stress conditions, which indicated that the forest utilized deep soil water to defend against environmental stress. Additionally, divergent responses of the gc to environmental factors in different climatic years were found. The results of this study provide detailed information on the gc variations and their specific responses to the environmental factors, which would improve the understanding of gc and help accurately estimate gc. … (more)
- Is Part Of:
- Ecological indicators. Volume 131(2021)
- Journal:
- Ecological indicators
- Issue:
- Volume 131(2021)
- Issue Display:
- Volume 131, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 131
- Issue:
- 2021
- Issue Sort Value:
- 2021-0131-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-11
- Subjects:
- Forest -- Flux -- Canopy conductance -- Temperature -- Vapor pressure deficit
Environmental monitoring -- Periodicals
Environmental management -- Periodicals
Environmental impact analysis -- Periodicals
Environmental risk assessment -- Periodicals
Sustainable development -- Periodicals
333.71405 - Journal URLs:
- http://www.sciencedirect.com/science/journal/1470160X/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ecolind.2021.108168 ↗
- Languages:
- English
- ISSNs:
- 1470-160X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3648.877200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19346.xml