Diagnostic test accuracy of 18F-FDG PET/CT for prediction of programmed death ligand 1 (PD-L1) expression in solid tumours: a meta-analysis. Issue 11 (November 2021)
- Record Type:
- Journal Article
- Title:
- Diagnostic test accuracy of 18F-FDG PET/CT for prediction of programmed death ligand 1 (PD-L1) expression in solid tumours: a meta-analysis. Issue 11 (November 2021)
- Main Title:
- Diagnostic test accuracy of 18F-FDG PET/CT for prediction of programmed death ligand 1 (PD-L1) expression in solid tumours: a meta-analysis
- Authors:
- Seol, H.Y.
Kim, Y.S.
Kim, S.-J. - Abstract:
- Abstract : AIM: To investigate the predictive value of integrated 2-[ 18 F]-fluoro-2-deoxy-d- glucose ( 18 F-FDG) positron-emission tomography/computed tomography (PET/CT) for the prediction of programmed death ligand 1 (PD-L1) expression in solid tumours via a systematic review and meta-analysis. MATERIALS AND METHODS: The PubMed, Cochrane, and EMBASE databases, from the earliest available date of indexing through 31 October 2020, were searched for studies evaluating the diagnostic performance of 18 F-FDG PET/CT for prediction of PD-L1 expression in solid tumours other than lung cancer. RESULTS: Across seven studies (473 patients), the pooled sensitivity for 18 F-FDG PET/CT was 0.75 (95% confidence interval [CI]: 0.65–0.82) without heterogeneity (I 2 = 47.2, p= 0.08) and a pooled specificity of 0.73 (95% CI: 0.64–0.81) with heterogeneity (I 2 = 53.8, p= 0.04). Likelihood ratio (LR) syntheses gave an overall positive likelihood ratio (LR+) of 2.8 (95% CI: 2.1–3.7) and negative likelihood ratio (LR–) of 0.35 (95% CI: 0.26–0.47). The pooled diagnostic odds ratio (DOR) was 8 (95% CI: 5–13). Hierarchical summary receiver operating characteristic (ROC) curve and indicates that the area under the curve was 0.80 (95% CI: 0.77–0.84). CONCLUSION: The current meta-analysis showed a moderate sensitivity and specificity of 18 F-FDG PET/CT for the prediction of PD-L1 expression in solid tumours. At present, the literature regarding the use of 18 F-FDG PET/CT for the prediction of PD-L1Abstract : AIM: To investigate the predictive value of integrated 2-[ 18 F]-fluoro-2-deoxy-d- glucose ( 18 F-FDG) positron-emission tomography/computed tomography (PET/CT) for the prediction of programmed death ligand 1 (PD-L1) expression in solid tumours via a systematic review and meta-analysis. MATERIALS AND METHODS: The PubMed, Cochrane, and EMBASE databases, from the earliest available date of indexing through 31 October 2020, were searched for studies evaluating the diagnostic performance of 18 F-FDG PET/CT for prediction of PD-L1 expression in solid tumours other than lung cancer. RESULTS: Across seven studies (473 patients), the pooled sensitivity for 18 F-FDG PET/CT was 0.75 (95% confidence interval [CI]: 0.65–0.82) without heterogeneity (I 2 = 47.2, p= 0.08) and a pooled specificity of 0.73 (95% CI: 0.64–0.81) with heterogeneity (I 2 = 53.8, p= 0.04). Likelihood ratio (LR) syntheses gave an overall positive likelihood ratio (LR+) of 2.8 (95% CI: 2.1–3.7) and negative likelihood ratio (LR–) of 0.35 (95% CI: 0.26–0.47). The pooled diagnostic odds ratio (DOR) was 8 (95% CI: 5–13). Hierarchical summary receiver operating characteristic (ROC) curve and indicates that the area under the curve was 0.80 (95% CI: 0.77–0.84). CONCLUSION: The current meta-analysis showed a moderate sensitivity and specificity of 18 F-FDG PET/CT for the prediction of PD-L1 expression in solid tumours. At present, the literature regarding the use of 18 F-FDG PET/CT for the prediction of PD-L1 expression in solid tumours still limited; thus, further large multicentre studies would be necessary to substantiate the diagnostic accuracy of 18 F-FDG PET/CT for prediction of PD-L1 expression in solid tumours. Highlights: The predictive value of F-18 FDG PET/CT was assessed for PD-L1expression. F-18 FDG PET/CT showed moderate diagnostic value. The F-18 FDG PET/CT might not be useful for PD-L1expression. … (more)
- Is Part Of:
- Clinical radiology. Volume 76:Issue 11(2021)
- Journal:
- Clinical radiology
- Issue:
- Volume 76:Issue 11(2021)
- Issue Display:
- Volume 76, Issue 11 (2021)
- Year:
- 2021
- Volume:
- 76
- Issue:
- 11
- Issue Sort Value:
- 2021-0076-0011-0000
- Page Start:
- 863.e19
- Page End:
- 863.e25
- Publication Date:
- 2021-11
- Subjects:
- Medical radiology -- Periodicals
Radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiology -- Periodicals
Societies, Medical -- Periodicals
Medical radiology
Radiotherapy
Electronic journals
Periodicals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00099260 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.crad.2021.06.012 ↗
- Languages:
- English
- ISSNs:
- 0009-9260
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.350000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19350.xml