Improving the coverage and accuracy of syphilis testing: The development of a novel rapid, point-of-care test for confirmatory testing of active syphilis infection and its early evaluation in China and South Africa. (July 2020)
- Record Type:
- Journal Article
- Title:
- Improving the coverage and accuracy of syphilis testing: The development of a novel rapid, point-of-care test for confirmatory testing of active syphilis infection and its early evaluation in China and South Africa. (July 2020)
- Main Title:
- Improving the coverage and accuracy of syphilis testing: The development of a novel rapid, point-of-care test for confirmatory testing of active syphilis infection and its early evaluation in China and South Africa
- Authors:
- Pham, Minh D.
Wise, Amy
Garcia, Mary L.
Van, Huy
Zheng, Shuning
Mohamed, Yasmin
Han, Yan
Wei, Wan-Hui
Yin, Yue-Ping
Chen, Xiang-Sheng
Dimech, Wayne
Braniff, Susie
Technau, Karl-Günter
Luchters, Stanley
Anderson, David A. - Abstract:
- Abstract: Background: Current point-of-care tests (POCT) for syphilis, based on the detection of Treponema pallidum (TP) total antibodies, have limited capacity in distinguishing between active and past/treated syphilis. We report the development and early evaluation of a new prototype POCT based on the detection of TP-IgA antibodies, a novel biomarker for active syphilis. Methods: The TP-IgA POCT (index test) was developed in response to the World Health Organisation (WHO) target product profile (TPP) for a POCT for confirmatory syphilis testing. Two sub-studies were conducted consecutively using 458 pre-characterised stored plasma samples in China (sub-study one, addressing the criteria for the WHO TPP), and 503 venous blood samples collected from pregnant/postpartum women in South Africa (sub-study two, addressing potential clinical utility). Performance of the index test was assessed against standard laboratory-based serology using a combination of treponemal (TPHA) and non-treponemal (rapid plasma reagin [RPR]) tests. Findings: In sub-study one, the index test demonstrated 96·1% (95%CI=91·7%-98·5%) sensitivity and 84·7% (95%CI=80·15–88·6%) specificity for identification of active syphilis (TPHA positive, RPR positive). It correctly identified 71% (107/150) samples of past-treated syphilis (TPHA positive, RPR negative). In sub-study two, the index test achieved 100% (95%CI=59%-100%) sensitivity for active syphilis and correctly identified all nine women with pastAbstract: Background: Current point-of-care tests (POCT) for syphilis, based on the detection of Treponema pallidum (TP) total antibodies, have limited capacity in distinguishing between active and past/treated syphilis. We report the development and early evaluation of a new prototype POCT based on the detection of TP-IgA antibodies, a novel biomarker for active syphilis. Methods: The TP-IgA POCT (index test) was developed in response to the World Health Organisation (WHO) target product profile (TPP) for a POCT for confirmatory syphilis testing. Two sub-studies were conducted consecutively using 458 pre-characterised stored plasma samples in China (sub-study one, addressing the criteria for the WHO TPP), and 503 venous blood samples collected from pregnant/postpartum women in South Africa (sub-study two, addressing potential clinical utility). Performance of the index test was assessed against standard laboratory-based serology using a combination of treponemal (TPHA) and non-treponemal (rapid plasma reagin [RPR]) tests. Findings: In sub-study one, the index test demonstrated 96·1% (95%CI=91·7%-98·5%) sensitivity and 84·7% (95%CI=80·15–88·6%) specificity for identification of active syphilis (TPHA positive, RPR positive). It correctly identified 71% (107/150) samples of past-treated syphilis (TPHA positive, RPR negative). In sub-study two, the index test achieved 100% (95%CI=59%-100%) sensitivity for active syphilis and correctly identified all nine women with past syphilis. Interpretation: The TP-IgA POCT has met the WHO TPP for a POCT for diagnosis of active syphilis and demonstrated its potential utility in a clinical setting. Future studies are warranted to evaluate field performance of the final manufactured test. Funding: Saving Lives at Birth: Grand Challenge for Development, Thrasher Research Fund, and the Victorian Government Operational Infrastructure Scheme. … (more)
- Is Part Of:
- EClinicalMedicine. Volume 24(2020)
- Journal:
- EClinicalMedicine
- Issue:
- Volume 24(2020)
- Issue Display:
- Volume 24, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 24
- Issue:
- 2020
- Issue Sort Value:
- 2020-0024-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-07
- Subjects:
- Syphilis -- IgA -- Diagnostic accuracy -- Point of care test -- South Africa -- China
Medicine -- Research -- Periodicals
Medical policy -- Periodicals
Clinical Medicine
Health Policy
Public Health
Medical policy
Medicine -- Research
Periodical
Electronic journals
Periodicals
613 - Journal URLs:
- https://www.sciencedirect.com/science/journal/25895370 ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.eclinm.2020.100440 ↗
- Languages:
- English
- ISSNs:
- 2589-5370
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19328.xml