Assessing the reproducibility of dynamic contrast enhanced magnetic resonance imaging in a murine model of breast cancer. Issue 6 (27th July 2012)
- Record Type:
- Journal Article
- Title:
- Assessing the reproducibility of dynamic contrast enhanced magnetic resonance imaging in a murine model of breast cancer. Issue 6 (27th July 2012)
- Main Title:
- Assessing the reproducibility of dynamic contrast enhanced magnetic resonance imaging in a murine model of breast cancer
- Authors:
- Barnes, Stephanie L.
Whisenant, Jennifer G.
Loveless, Mary E.
Ayers, Gregory D.
Yankeelov, Thomas E. - Abstract:
- Abstract: Quantitative dynamic contrast enhanced magnetic resonance imaging estimates parameters related to tissue vascularity and volume fractions; additionally, semiquantitative parameters such as the initial area under the curve can be utilized to describe tissue behavior. The aim of this study was to establish the reproducibility of quantitative and semiquantitative analysis of dynamic contrast enhanced magnetic resonance imaging in a murine model of breast cancer. For each animal, a T 1 ‐weighted, gradient‐echo sequence was used to acquire two sets of dynamic contrast enhanced magnetic resonance imaging data separated by 5 h. Data were acquired at both a 0.05 mm 3 (128 2, n = 12) and a 0.2 mm 3 (64 2, n = 12) resolution, and analysis was performed using both the Tofts–Kety (to estimate K trans and v e ) and extended Tofts–Kety ( K trans, v e, and v p ) models. Reproducibility analysis was performed for both the center slice and the total tumor volume for all parameters. For the total volume analysis, the repeatability index for K trans is 0.073 min −1 in the standard model analysis and 0.075 min −1 in the extended model analysis at the 128 2 acquisition. For the 64 2 acquisition, the values are 0.089 and 0.063 min −1 for the standard and extended models, respectively. The repeatability index for initial area under the curve was 0.0039 and 0.0042 mM min for the 128 2 and 64 2 acquisitions, respectively. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.
- Is Part Of:
- Magnetic resonance in medicine. Volume 69:Issue 6(2013:Jun.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 69:Issue 6(2013:Jun.)
- Issue Display:
- Volume 69, Issue 6 (2013)
- Year:
- 2013
- Volume:
- 69
- Issue:
- 6
- Issue Sort Value:
- 2013-0069-0006-0000
- Page Start:
- 1721
- Page End:
- 1734
- Publication Date:
- 2012-07-27
- Subjects:
- reproducibility -- DCE‐MRI -- breast cancer -- mouse
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.24422 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19324.xml