Measuring B1 distributions by B1 phase encoding. Issue 1 (17th January 2016)
- Record Type:
- Journal Article
- Title:
- Measuring B1 distributions by B1 phase encoding. Issue 1 (17th January 2016)
- Main Title:
- Measuring B1 distributions by B1 phase encoding
- Authors:
- Jordanova, Kalina V.
Nishimura, Dwight G.
Kerr, Adam B. - Abstract:
- Abstract : Purpose: We propose a method to acquire B 1 distribution plots by encoding in B 1 instead of image space. Using this method, B 1 data is acquired in a different way from traditional spatial B 1 mapping, and allows for quick measurement of high dynamic range B 1 data. Methods: To encode in B 1, we acquire multiple projections of a slice, each along the same direction, but using a different phase sensitivity to B 1 . Using a convex optimization formulation, we reconstruct histograms of the B 1 distribution estimates of the slice. Results: We verify in vivo B 1 distribution measurements by comparing measured distributions to distributions calculated from reference spatial B 1 maps using the Earth Mover's Distance. Phantom measurements using a surface coil show that for increased spatial B 1 variations, measured B 1 distributions using the proposed method more accurately estimate the distribution than a low‐resolution spatial B 1 map, resulting in a 37% Earth Mover's Distance decrease while using fewer measurements. Conclusion: We propose and validate the performance of a method to acquire B 1 distribution information directly without acquiring a spatial B 1 map. The method may provide faster estimates of a B 1 field for applications that do not require spatial B 1 localization, such as the transmit gain calibration of the scanner, particularly for high dynamic B 1 ranges. Magn Reson Med 77:229–236, 2017. © 2016 Wiley Periodicals, Inc.
- Is Part Of:
- Magnetic resonance in medicine. Volume 77:Issue 1(2017)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 77:Issue 1(2017)
- Issue Display:
- Volume 77, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 77
- Issue:
- 1
- Issue Sort Value:
- 2017-0077-0001-0000
- Page Start:
- 229
- Page End:
- 236
- Publication Date:
- 2016-01-17
- Subjects:
- B1 distributions -- B1 mapping
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26114 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19307.xml