Sternick, Edward S. - Abstract:
- Abstract : The authors compared the relative dosimetric merits of Gamma Knife (GK) and CyberKnife (CK) in 15 patients with 26 brain metastases. All patients were initially treated with the Leksell GK 4C. The same patients were used to generate comparative CK treatment plans. The tissue volume receiving more than 12 Gy (V12), the difference between V12 and tumor volume (V12net), homogeneity index (HI), and gradient indices (GI25, GI50) were calculated. Peripheral dose falloff and three conformity indices were compared. The median tumor volume was 2.50 cm 3 (range, 0. 044‐19.9). A median dose of 18 Gy (range, 15‐22) was prescribed. In GK and CK plans, doses were prescribed to the 40‐50% and 77‐92% isodose lines, respectively. Comparing GK to CK, the respective parametric values ( median ± standard deviation ) were: minimum dose ( 18.2 ± 3.4 vs. 17.6 ± 2.4 Gy, p = 0.395 ); mean dose ( 29.6 ± 5.1 vs. 20.6 ± 2.8 Gy, p < 0.00001 ); maximum dose ( 40.3 ± 6.5 vs. 22.7 ± 3.3 Gy, p < 0.00001 ); and HI ( 2.22 ± 0.19 vs. 1.18 ± 0.06, p < 0.00001 ). The median dosimetric indices (GK vs. CK, with range) were: RTOG_CI, 1.76 (1.12‐4.14) vs. 1.53 (1.16‐2.12), p = 0.0220 ; CI, 1.76 (1.15‐4.14) vs. 1.55 (1.18‐2.21), p = 0.050 ; nCI, 1.76 (1.59‐4.14) vs. 1.57 (1.20‐2.30), p = 0.082 ; GI50, 2.91 (2.48‐3.67) vs. 4.90 (3.42‐11.68), p < 0.00001 ; GI25, 6.58 (4.18‐10.20) vs. 14.85 (8.80‐48.37), p < 0.00001 . Average volume ratio (AVR) differences favored GK at multiple normalized isodoseAbstract : The authors compared the relative dosimetric merits of Gamma Knife (GK) and CyberKnife (CK) in 15 patients with 26 brain metastases. All patients were initially treated with the Leksell GK 4C. The same patients were used to generate comparative CK treatment plans. The tissue volume receiving more than 12 Gy (V12), the difference between V12 and tumor volume (V12net), homogeneity index (HI), and gradient indices (GI25, GI50) were calculated. Peripheral dose falloff and three conformity indices were compared. The median tumor volume was 2.50 cm 3 (range, 0. 044‐19.9). A median dose of 18 Gy (range, 15‐22) was prescribed. In GK and CK plans, doses were prescribed to the 40‐50% and 77‐92% isodose lines, respectively. Comparing GK to CK, the respective parametric values ( median ± standard deviation ) were: minimum dose ( 18.2 ± 3.4 vs. 17.6 ± 2.4 Gy, p = 0.395 ); mean dose ( 29.6 ± 5.1 vs. 20.6 ± 2.8 Gy, p < 0.00001 ); maximum dose ( 40.3 ± 6.5 vs. 22.7 ± 3.3 Gy, p < 0.00001 ); and HI ( 2.22 ± 0.19 vs. 1.18 ± 0.06, p < 0.00001 ). The median dosimetric indices (GK vs. CK, with range) were: RTOG_CI, 1.76 (1.12‐4.14) vs. 1.53 (1.16‐2.12), p = 0.0220 ; CI, 1.76 (1.15‐4.14) vs. 1.55 (1.18‐2.21), p = 0.050 ; nCI, 1.76 (1.59‐4.14) vs. 1.57 (1.20‐2.30), p = 0.082 ; GI50, 2.91 (2.48‐3.67) vs. 4.90 (3.42‐11.68), p < 0.00001 ; GI25, 6.58 (4.18‐10.20) vs. 14.85 (8.80‐48.37), p < 0.00001 . Average volume ratio (AVR) differences favored GK at multiple normalized isodose levels ( p < 0.00001 ) . We concluded that in patients with brain metastases, CK and GK resulted in dosimetrically comparable plans that were nearly equivalent in several metrics, including target coverage and minimum dose within the target. Compared to GK, CK produced more homogenous plans with significantly lower mean and maximum doses, and achieved more conformal plans by RTOG_CI criteria. By GI and AVR analyses, GK plans had sharper peripheral dose falloff in most cases. PACS number: 89.20.‐a … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 15:Number 1(2014)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 15:Number 1(2014)
- Issue Display:
- Volume 15, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 15
- Issue:
- 1
- Issue Sort Value:
- 2014-0015-0001-0000
- Page Start:
- 14
- Page End:
- 26
- Publication Date:
- 2014-01-06
- Subjects:
- Gamma Knife -- CyberKnife -- dosimetry -- dosimetric comparison -- brain metastases
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v15i1.4095 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19318.xml