Three‐Dimensional Transesophageal Echocardiography Assessment of a Successful Transcatheter Mitral Valve in Valve Implantation for Degenerated Bioprosthesis. Issue 6 (12th March 2013)
- Record Type:
- Journal Article
- Title:
- Three‐Dimensional Transesophageal Echocardiography Assessment of a Successful Transcatheter Mitral Valve in Valve Implantation for Degenerated Bioprosthesis. Issue 6 (12th March 2013)
- Main Title:
- Three‐Dimensional Transesophageal Echocardiography Assessment of a Successful Transcatheter Mitral Valve in Valve Implantation for Degenerated Bioprosthesis
- Authors:
- Théron, Alexis
Gariboldi, Vlad
Grisoli, Dominique
Maysou, Laurie‐anne
Jaussaud, Nicolas
Morera, Pierre
Cuisset, Thomas
Quilici, Jacques
Thuny, Franck
Riberi, Alberto
Avierinos, Jean‐François
Collart, Frederic - Abstract:
- Abstract : Reoperation for degenerated mitral bioprosthesis is considered a high risk procedure. Transcatheter mitral valve in valve implantation has emerged as an off‐label alternative for patients contra‐indicated to surgery. We report a 46‐year‐old man, with a 29 mm mitral bioprosthesis since 2002, who was admitted for acute heart failure because of a severe intra‐prosthetic regurgitation. His recent medical history revealed a fast growing cavum carcinoma. In view of generally poor prognosis, the heart team decided to perform a transcatheter mitral valve in valve implantation by transapical approach. Live three‐dimensional TEE was used during the implantation for sizing, device positioning, and hemodynamic assessment. Mini‐Abstract: Reoperation for degenerated mitral bioprosthesis is considered a high risk procedure. Transcatheter mitral valve in valve implantation has emerged as an off label alternative for patients contra‐indicated to surgery. During the implantation, live three‐dimensional (3D) TEE is an accurate imaging modality for sizing, device positioning, and hemodynamic assessment.
- Is Part Of:
- Echocardiography. Volume 30:Issue 6(2013)
- Journal:
- Echocardiography
- Issue:
- Volume 30:Issue 6(2013)
- Issue Display:
- Volume 30, Issue 6 (2013)
- Year:
- 2013
- Volume:
- 30
- Issue:
- 6
- Issue Sort Value:
- 2013-0030-0006-0000
- Page Start:
- E152
- Page End:
- E155
- Publication Date:
- 2013-03-12
- Subjects:
- valve in valve -- degenerated bioprosthesis -- 3DTEE -- TAVI
Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.12177 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19308.xml