Fast and accurate multi‐channel B1+ mapping based on the TIAMO technique for 7T UHF body MRI. Issue 5 (9th October 2017)
- Record Type:
- Journal Article
- Title:
- Fast and accurate multi‐channel B1+ mapping based on the TIAMO technique for 7T UHF body MRI. Issue 5 (9th October 2017)
- Main Title:
- Fast and accurate multi‐channel B1+ mapping based on the TIAMO technique for 7T UHF body MRI
- Authors:
- Brunheim, Sascha
Gratz, Marcel
Johst, Sören
Bitz, Andreas K.
Fiedler, Thomas M.
Ladd, Mark E.
Quick, Harald H.
Orzada, Stephan - Abstract:
- Abstract : Purpose: Current methods for mitigation of transmit field B 1 + inhomogeneities at ultrahigh field (UHF) MRI by multi‐channel radiofrequency (RF) shimming rely on accurate B 1 + mapping. This can be time consuming when many RF channels have to be mapped for in vivo body MRI, where the B1 maps should ideally be acquired within a single breath‐hold. Therefore, a new B 1 + mapping technique (B1TIAMO) is proposed. Methods: The performance of this technique is validated against an established method (DREAM) in phantom measurements for a cylindrical head phantom with an 8‐channel transmit/receive (Tx/Rx) array. Furthermore, measurements for a 32‐channel Tx/Rx remote array are conducted in a large body phantom and the | B 1 + | map reliability is validated against simulations of the transmit RF field distribution. Finally, in vivo results of this new mapping technique for human abdomen are presented. Results: For the head phantom (8‐channel Tx/Rx coil), the single | B 1 + | comparison between B1 TIAMO, the direct DREAM measurements, and simulation data showed good agreement with 10–19% difference. For the large body phantom (32‐channel Tx/Rx coil), B1TIAMO matched the RF field simulations well. Conclusion: The results demonstrate the potential to acquire 32 accurate single‐channel B 1 + maps for large field‐of‐view body imaging within only a single breath‐hold of 16 s at 7T UHF MRI. Magn Reson Med 79:2652–2664, 2018. © 2017 International Society for Magnetic Resonance inAbstract : Purpose: Current methods for mitigation of transmit field B 1 + inhomogeneities at ultrahigh field (UHF) MRI by multi‐channel radiofrequency (RF) shimming rely on accurate B 1 + mapping. This can be time consuming when many RF channels have to be mapped for in vivo body MRI, where the B1 maps should ideally be acquired within a single breath‐hold. Therefore, a new B 1 + mapping technique (B1TIAMO) is proposed. Methods: The performance of this technique is validated against an established method (DREAM) in phantom measurements for a cylindrical head phantom with an 8‐channel transmit/receive (Tx/Rx) array. Furthermore, measurements for a 32‐channel Tx/Rx remote array are conducted in a large body phantom and the | B 1 + | map reliability is validated against simulations of the transmit RF field distribution. Finally, in vivo results of this new mapping technique for human abdomen are presented. Results: For the head phantom (8‐channel Tx/Rx coil), the single | B 1 + | comparison between B1 TIAMO, the direct DREAM measurements, and simulation data showed good agreement with 10–19% difference. For the large body phantom (32‐channel Tx/Rx coil), B1TIAMO matched the RF field simulations well. Conclusion: The results demonstrate the potential to acquire 32 accurate single‐channel B 1 + maps for large field‐of‐view body imaging within only a single breath‐hold of 16 s at 7T UHF MRI. Magn Reson Med 79:2652–2664, 2018. © 2017 International Society for Magnetic Resonance in Medicine. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 79:Issue 5(2018)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 79:Issue 5(2018)
- Issue Display:
- Volume 79, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 79
- Issue:
- 5
- Issue Sort Value:
- 2018-0079-0005-0000
- Page Start:
- 2652
- Page End:
- 2664
- Publication Date:
- 2017-10-09
- Subjects:
- B1+ field -- flip angle mapping -- RF shimming -- 7T ultrahigh field MRI -- 32‐channel transmit/receive RF coil -- 7T body imaging
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26925 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19321.xml