Repeatability of ultrashort echo time‐based two‐component T2* measurements on cartilages in human knee at 3 T. Issue 6 (3rd October 2012)
- Record Type:
- Journal Article
- Title:
- Repeatability of ultrashort echo time‐based two‐component T2* measurements on cartilages in human knee at 3 T. Issue 6 (3rd October 2012)
- Main Title:
- Repeatability of ultrashort echo time‐based two‐component T2* measurements on cartilages in human knee at 3 T
- Authors:
- Qian, Yongxian
Williams, Ashley A.
Chu, Constance R.
Boada, Fernando E. - Abstract:
- Abstract: Repeatability of in vivo measurement of multicomponent T 2 * relaxation in articular cartialges in human knee is important to clinical use. This study evaluated the repeatability of two‐component T 2 * relaxation on seven healthy human subjects. The left knee was scanned once a day in three consecutive days, on a clinical 3T MRI scanner with eight‐channel knee coil and ultrashort echo time pulse sequence at 11 echo times = 0.6–40 ms. The intrasubject and intersubject repeatability was evaluated via coefficient of variation (CV = standard deviation/mean) in four typical cartilage regions: patellar, anterior articular, femoral, and tibial regions. It was found that the intrasubject repeatability was good, with CV < 10% for the short‐ and long‐ T 2 * relaxation time in the layered regions in the four cartilages (with one exception) and CV < 13% for the component intensity fraction (with two exceptions). The intersubject repeatability was also good, with CV ∼8% (range 1–15%) for the short‐ and long‐ T 2 * relaxation time and CV ∼10% (range 2–20%) for the component intensity fraction. The long‐ T 2 * component showed significantly better repeatability (CV ∼8%) than the short‐ T 2 * component (CV∼12%) ( P < 0.005). These CV values suggest that in vivo measurement of two‐component T 2 * relaxation in the knee cartilages is repeatable on clinical scanner at 3 T, with a signal‐to‐noise ratio of 90. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.
- Is Part Of:
- Magnetic resonance in medicine. Volume 69:Issue 6(2013:Jun.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 69:Issue 6(2013:Jun.)
- Issue Display:
- Volume 69, Issue 6 (2013)
- Year:
- 2013
- Volume:
- 69
- Issue:
- 6
- Issue Sort Value:
- 2013-0069-0006-0000
- Page Start:
- 1564
- Page End:
- 1571
- Publication Date:
- 2012-10-03
- Subjects:
- repeatability -- T2* relaxation -- multiple component -- knee cartilage -- ultrashort echo time imaging
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.24392 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19324.xml