Modulation factors calculated with an EPID‐derived MLC fluence model to streamline IMRT/VMAT second checks. (8th November 2013)
- Record Type:
- Journal Article
- Title:
- Modulation factors calculated with an EPID‐derived MLC fluence model to streamline IMRT/VMAT second checks. (8th November 2013)
- Main Title:
- Modulation factors calculated with an EPID‐derived MLC fluence model to streamline IMRT/VMAT second checks
- Authors:
- Steciw, Stephen
Rathee, Satyapal
Warkentin, Brad - Abstract:
- Abstract : This work outlines the development of a robust method of calculating modulation factors used for the independent verification of MUs for IMRT and VMAT treatments, to replace onerous ion chamber measurements. Two‐dimensional fluence maps were calculated for dynamic MLC fields that include MLC interleaf leakage, transmission, and tongue‐and‐groove effects, as characterized from EPID‐acquired images. Monte Carlo‐generated dose kernels were then used to calculate doses for a modulated field and that field with the modulation removed at a depth specific to the calculation point in the patient using in‐house written software, Mod_Calc. The ratio of these two doses was taken to calculate modulation factors. Comparison between Mod_Calc calculation and ion chamber measurement of modulation factors for 121 IMRT fields yielded excellent agreement, where the mean difference between the two was − 0.3 % ± 1.2 % . This validated use of Mod_Calc clinically. Analysis of 5, 271 dynamic fields from clinical use of Mod_Calc gave a mean difference of 0.3 % ± 1.0 % between Mod_Calc and Eclipse‐generated factors. In addition, 99.3% and 96.5% fields pass 5% and 2% criteria, respectively, for agreement between these two predictions. The development and use of Mod_Calc at our clinic has considerably streamlined our QA process for IMRT and RapidArc fields, compared to our previous method based on ion chamber measurements. As a result, it has made it feasible to maintain our established andAbstract : This work outlines the development of a robust method of calculating modulation factors used for the independent verification of MUs for IMRT and VMAT treatments, to replace onerous ion chamber measurements. Two‐dimensional fluence maps were calculated for dynamic MLC fields that include MLC interleaf leakage, transmission, and tongue‐and‐groove effects, as characterized from EPID‐acquired images. Monte Carlo‐generated dose kernels were then used to calculate doses for a modulated field and that field with the modulation removed at a depth specific to the calculation point in the patient using in‐house written software, Mod_Calc. The ratio of these two doses was taken to calculate modulation factors. Comparison between Mod_Calc calculation and ion chamber measurement of modulation factors for 121 IMRT fields yielded excellent agreement, where the mean difference between the two was − 0.3 % ± 1.2 % . This validated use of Mod_Calc clinically. Analysis of 5, 271 dynamic fields from clinical use of Mod_Calc gave a mean difference of 0.3 % ± 1.0 % between Mod_Calc and Eclipse‐generated factors. In addition, 99.3% and 96.5% fields pass 5% and 2% criteria, respectively, for agreement between these two predictions. The development and use of Mod_Calc at our clinic has considerably streamlined our QA process for IMRT and RapidArc fields, compared to our previous method based on ion chamber measurements. As a result, it has made it feasible to maintain our established and trusted current in‐house method of MU verification, without resorting to commercial software alternatives. PACS numbers: 87.55.km, 87.55.Qr, 87.55.kd, 87.57.uq … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 14:Number 6(2013)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 14:Number 6(2013)
- Issue Display:
- Volume 14, Issue 6 (2013)
- Year:
- 2013
- Volume:
- 14
- Issue:
- 6
- Issue Sort Value:
- 2013-0014-0006-0000
- Page Start:
- 62
- Page End:
- 81
- Publication Date:
- 2013-11-08
- Subjects:
- modulation factor -- IMRT -- VMAT -- EPID -- tongue and groove -- verification
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v14i6.4274 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19314.xml