Cardiovascular magnetic resonance feature-tracking assessment of myocardial mechanics: Intervendor agreement and considerations regarding reproducibility. Issue 9 (September 2015)
- Record Type:
- Journal Article
- Title:
- Cardiovascular magnetic resonance feature-tracking assessment of myocardial mechanics: Intervendor agreement and considerations regarding reproducibility. Issue 9 (September 2015)
- Main Title:
- Cardiovascular magnetic resonance feature-tracking assessment of myocardial mechanics: Intervendor agreement and considerations regarding reproducibility
- Authors:
- Schuster, A.
Stahnke, V.-C.
Unterberg-Buchwald, C.
Kowallick, J.T.
Lamata, P.
Steinmetz, M.
Kutty, S.
Fasshauer, M.
Staab, W.
Sohns, J.M.
Bigalke, B.
Ritter, C.
Hasenfuß, G.
Beerbaum, P.
Lotz, J. - Abstract:
- Abstract : Aim: To assess intervendor agreement of cardiovascular magnetic resonance feature tracking (CMR-FT) and to study the impact of repeated measures on reproducibility. Materials and methods: Ten healthy volunteers underwent cine imaging in short-axis orientation at rest and with dobutamine stimulation (10 and 20 μg/kg/min). All images were analysed three times using two types of software (TomTec, Unterschleissheim, Germany and Circle, cvi 42, Calgary, Canada) to assess global left ventricular circumferential (Ecc) and radial (Err) strains and torsion. Differences in intra- and interobserver variability within and between software types were assessed based on single and averaged measurements (two and three repetitions with subsequent averaging of results, respectively) as determined by Bland–Altman analysis, intraclass correlation coefficients (ICC), and coefficient of variation (CoV). Results: Myocardial strains and torsion significantly increased on dobutamine stimulation with both types of software ( p< 0.05). Resting Ecc and torsion as well as Ecc values during dobutamine stimulation were lower measured with Circle ( p< 0.05). Intra- and interobserver variability between software types was lowest for Ecc (ICC 0.81 [0.63–0.91], 0.87 [0.72–0.94] and CoV 12.47% and 14.3%, respectively) irrespective of the number of analysis repetitions. Err and torsion showed higher variability that markedly improved for torsion with repeated analyses and to a lesser extent for Err.Abstract : Aim: To assess intervendor agreement of cardiovascular magnetic resonance feature tracking (CMR-FT) and to study the impact of repeated measures on reproducibility. Materials and methods: Ten healthy volunteers underwent cine imaging in short-axis orientation at rest and with dobutamine stimulation (10 and 20 μg/kg/min). All images were analysed three times using two types of software (TomTec, Unterschleissheim, Germany and Circle, cvi 42, Calgary, Canada) to assess global left ventricular circumferential (Ecc) and radial (Err) strains and torsion. Differences in intra- and interobserver variability within and between software types were assessed based on single and averaged measurements (two and three repetitions with subsequent averaging of results, respectively) as determined by Bland–Altman analysis, intraclass correlation coefficients (ICC), and coefficient of variation (CoV). Results: Myocardial strains and torsion significantly increased on dobutamine stimulation with both types of software ( p< 0.05). Resting Ecc and torsion as well as Ecc values during dobutamine stimulation were lower measured with Circle ( p< 0.05). Intra- and interobserver variability between software types was lowest for Ecc (ICC 0.81 [0.63–0.91], 0.87 [0.72–0.94] and CoV 12.47% and 14.3%, respectively) irrespective of the number of analysis repetitions. Err and torsion showed higher variability that markedly improved for torsion with repeated analyses and to a lesser extent for Err. On an intravendor level TomTec showed better reproducibility for Ecc and torsion and Circle for Err. Conclusions: CMR-FT strain and torsion measurements are subject to considerable intervendor variability, which can be reduced using three analysis repetitions. For both vendors, Ecc qualifies as the most robust parameter with the best agreement, albeit lower Ecc values obtained using Circle, and warrants further investigation of incremental clinical merit. Highlights: This is the first comparison of two types of CMR-FT software resulting in clinically valuable inter-vendor agreement data. Assessment of myocardial strain and torsion is feasible with both types of software at rest and with dobutamine stimulation. For both vendors, Ecc qualifies as the most robust parameter with the lowest variability. … (more)
- Is Part Of:
- Clinical radiology. Volume 70:Issue 9(2015)
- Journal:
- Clinical radiology
- Issue:
- Volume 70:Issue 9(2015)
- Issue Display:
- Volume 70, Issue 9 (2015)
- Year:
- 2015
- Volume:
- 70
- Issue:
- 9
- Issue Sort Value:
- 2015-0070-0009-0000
- Page Start:
- 989
- Page End:
- 998
- Publication Date:
- 2015-09
- Subjects:
- Medical radiology -- Periodicals
Radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiology -- Periodicals
Societies, Medical -- Periodicals
Medical radiology
Radiotherapy
Electronic journals
Periodicals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00099260 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.crad.2015.05.006 ↗
- Languages:
- English
- ISSNs:
- 0009-9260
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.350000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19311.xml