Proportional integral feedback control of ultrafiltration rate in hemodialysis. Issue 3 (March 2022)
- Record Type:
- Journal Article
- Title:
- Proportional integral feedback control of ultrafiltration rate in hemodialysis. Issue 3 (March 2022)
- Main Title:
- Proportional integral feedback control of ultrafiltration rate in hemodialysis
- Authors:
- Casper, Sabrina
Fuertinger, Doris H
Tapia Silva, Leticia M
Rivera Fuentes, Lemuel
Thijssen, Stephan
Kotanko, Peter - Abstract:
- Background: Most hemodialysis patients without residual kidney function accumulate fluid between dialysis session that needs to be removed by ultrafiltration. Ultrafiltration usually results in a decline in relative blood volume (RBV). Recent epidemiological research has identified RBV ranges that were associated with significantly better survival. The objective of this work was to develop an ultrafiltration controller to steer a patient's RBV trajectory into these favorable RBV ranges. Methods: We designed a proportional-integral feedback ultrafiltration controller that utilizes signals from a device that reports RBV. The control goal is to attain the RBV trajectory associated with improved patient survival. Additional constraints such as upper and lower bounds of ultrafiltration volume and rate were realized. The controller was evaluated in in silico and ex vivo bench experiments, and in a clinical proof-of-concept study in two maintenance dialysis patients. Results: In all tests, the ultrafiltration controller performed as expected. In the in silico and ex vivo bench experiments, the controller showed robust reaction toward deliberate disruptive interventions (e.g. signal noise; extreme plasma refill rates). No adverse events were observed in the clinical study. Conclusions: The ultrafiltration controller can steer RBV trajectories toward desired RBV ranges while obeying to a set of constraints. Prospective studies in hemodialysis patients with diverse clinicalBackground: Most hemodialysis patients without residual kidney function accumulate fluid between dialysis session that needs to be removed by ultrafiltration. Ultrafiltration usually results in a decline in relative blood volume (RBV). Recent epidemiological research has identified RBV ranges that were associated with significantly better survival. The objective of this work was to develop an ultrafiltration controller to steer a patient's RBV trajectory into these favorable RBV ranges. Methods: We designed a proportional-integral feedback ultrafiltration controller that utilizes signals from a device that reports RBV. The control goal is to attain the RBV trajectory associated with improved patient survival. Additional constraints such as upper and lower bounds of ultrafiltration volume and rate were realized. The controller was evaluated in in silico and ex vivo bench experiments, and in a clinical proof-of-concept study in two maintenance dialysis patients. Results: In all tests, the ultrafiltration controller performed as expected. In the in silico and ex vivo bench experiments, the controller showed robust reaction toward deliberate disruptive interventions (e.g. signal noise; extreme plasma refill rates). No adverse events were observed in the clinical study. Conclusions: The ultrafiltration controller can steer RBV trajectories toward desired RBV ranges while obeying to a set of constraints. Prospective studies in hemodialysis patients with diverse clinical characteristics are warranted to further explore the controllers impact on intradialytic hemodynamic stability, quality of life, and long-term outcomes. … (more)
- Is Part Of:
- International journal of artificial organs. Volume 45:Issue 3(2022)
- Journal:
- International journal of artificial organs
- Issue:
- Volume 45:Issue 3(2022)
- Issue Display:
- Volume 45, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 45
- Issue:
- 3
- Issue Sort Value:
- 2022-0045-0003-0000
- Page Start:
- 271
- Page End:
- 277
- Publication Date:
- 2022-03
- Subjects:
- Automated feedback system -- hemodialysis -- artificial kidney -- ultrafiltration rate feedback control -- closed-loop controller -- relative blood volume
Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://catalog.hathitrust.org/api/volumes/oclc/3676874.html ↗
http://www.artificial-organs.com/ ↗
http://www.wichtig-publisher.com/jao/ ↗
http://www.uk.sagepub.com/home.nav ↗
http://journals.sagepub.com/loi/jaoa ↗
https://us.sagepub.com/en-us/nam/the-international-journal-of-artificial-organs/journal203459 ↗ - DOI:
- 10.1177/03913988211069395 ↗
- Languages:
- English
- ISSNs:
- 0391-3988
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19279.xml