Demonstrating the Clinical Impact of Continuous Glucose Monitoring Within an Integrated Healthcare Delivery System. (March 2022)
- Record Type:
- Journal Article
- Title:
- Demonstrating the Clinical Impact of Continuous Glucose Monitoring Within an Integrated Healthcare Delivery System. (March 2022)
- Main Title:
- Demonstrating the Clinical Impact of Continuous Glucose Monitoring Within an Integrated Healthcare Delivery System
- Authors:
- Isaacson, Brad
Kaufusi, Stephanie
Sorensen, Jeff
Joy, Elizabeth
Jones, Christopher
Ingram, Valerie
Mark, Nickolas
Phillips, Mike
Briesacher, Mark - Abstract:
- Background: Approximately 30 million Americans currently suffer from diabetes, and nearly 55 million people will be impacted by 2030. Continuous glucose monitoring (CGM) systems help patients manage their care with real-time data. Although approximately 95% of those with diabetes suffer from type 2, few studies have measured CGM's clinical impact for this segment within an integrated healthcare system. Methods: A parallel randomized, multisite prospective trial was conducted using a new CGM device (Dexcom G6) compared to a standard of care finger stick glucometer (FSG) (Contour Next One). All participants received usual care in primary care clinics for six consecutive months while using these devices. Data were collected via electronic medical records, device outputs, exit surveys, and insurance company (SelectHealth) claims in accordance with institutional review board approval. Results: Ninety-nine patients were randomized for analysis ( n = 50 CGM and n = 49 FSG). CGM patients significantly decreased hemoglobin A1c ( p = .001), total visits ( p = .009), emergency department encounters ( p = .018), and labs ordered ( p = .001). Among SelectHealth non-Medicare Advantage patients, per member per month savings were $417 for CGM compared to FSG, but $9 more for Medicare Advantage. Seventy percent of CGM users reported that the technology helped them better understand daily activity and diet compared to only 16% for FSG. Discussion: Participants using CGM devices hadBackground: Approximately 30 million Americans currently suffer from diabetes, and nearly 55 million people will be impacted by 2030. Continuous glucose monitoring (CGM) systems help patients manage their care with real-time data. Although approximately 95% of those with diabetes suffer from type 2, few studies have measured CGM's clinical impact for this segment within an integrated healthcare system. Methods: A parallel randomized, multisite prospective trial was conducted using a new CGM device (Dexcom G6) compared to a standard of care finger stick glucometer (FSG) (Contour Next One). All participants received usual care in primary care clinics for six consecutive months while using these devices. Data were collected via electronic medical records, device outputs, exit surveys, and insurance company (SelectHealth) claims in accordance with institutional review board approval. Results: Ninety-nine patients were randomized for analysis ( n = 50 CGM and n = 49 FSG). CGM patients significantly decreased hemoglobin A1c ( p = .001), total visits ( p = .009), emergency department encounters ( p = .018), and labs ordered ( p = .001). Among SelectHealth non-Medicare Advantage patients, per member per month savings were $417 for CGM compared to FSG, but $9 more for Medicare Advantage. Seventy percent of CGM users reported that the technology helped them better understand daily activity and diet compared to only 16% for FSG. Discussion: Participants using CGM devices had meaningful improvements in clinical outcomes, costs, and self-reported measures compared to the FSG group. Although a larger study is necessary to confirm these results, CGM devices appear to improve patient outcomes while making treatment more affordable. … (more)
- Is Part Of:
- Journal of diabetes science and technology. Volume 16:Number 2(2022)
- Journal:
- Journal of diabetes science and technology
- Issue:
- Volume 16:Number 2(2022)
- Issue Display:
- Volume 16, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 16
- Issue:
- 2
- Issue Sort Value:
- 2022-0016-0002-0000
- Page Start:
- 383
- Page End:
- 389
- Publication Date:
- 2022-03
- Subjects:
- diabetes -- continuous glucose monitoring -- CGM -- healthcare
Diabetes -- Periodicals
Medical technology -- Periodicals
Diabetes Mellitus -- Periodicals
616.462005 - Journal URLs:
- http://ejournals.ebsco.com/direct.asp?JournalID=712321 ↗
http://www.jodsat.org/about.html ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/1932296820955228 ↗
- Languages:
- English
- ISSNs:
- 1932-2968
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19276.xml