Clinical outcomes in pediatric tibial lengthening and deformity correction: A comparison of the Taylor Spatial Frame with the Orthex Hexapod System. (April 2021)
- Record Type:
- Journal Article
- Title:
- Clinical outcomes in pediatric tibial lengthening and deformity correction: A comparison of the Taylor Spatial Frame with the Orthex Hexapod System. (April 2021)
- Main Title:
- Clinical outcomes in pediatric tibial lengthening and deformity correction: A comparison of the Taylor Spatial Frame with the Orthex Hexapod System
- Authors:
- Messner, Juergen
Chhina, Harpreet
Davidson, Sophia
Abad, Jero
Cooper, Anthony - Abstract:
- Abstract: Purpose: Comparison of two hexapod frame systems in paediatric tibial deformity correction; the Taylor Spatial Frame (TSF) and Orthex Hexapod System. Methods: Paediatric patients with congenital and acquired tibial deformities treated with either TSF (between 2014 and 2016) or Orthex (between 2017 and 2019) frames were included in a retrospective comparative study. Outcome measures were healing index, pin infection rate, regenerate quality and density, software residual rate, deformity correction accuracy, strut exchanges and quality of life (QoL). Results: The TSF group had 17 patients (18 frames) and the Orthex group had 21 patients (25 frames). The most common indications for tibial deformity correction were fibular hemimelia (14) and septic or traumatic growth arrest (8). The median time in frame was 230 days (TSF) versus 203 days (Orthex) (p= 0.06). The mean lengthening achieved was 54 mm (TSF) and 51 mm (Orthex) (p = 0.41). The healing index was 41 days/cm (TSF) versus 43 days/cm (Orthex) (p = 0.70). Pin site infections occurred more in the TSF cohort (40%) than in the Orthex cohort (18%) (p < 0.001). The regenerate in the Orthex group showed higher density at three months (p = 0.029) and was more homogenous (p = 0.023) at six months after frame application. Strut exchanges were less frequent with the Orthex system (p < 0.0001). QoL measures were similar in both cohorts (p = 0.92). Conclusions: This is the first study to compare two hexapod designs inAbstract: Purpose: Comparison of two hexapod frame systems in paediatric tibial deformity correction; the Taylor Spatial Frame (TSF) and Orthex Hexapod System. Methods: Paediatric patients with congenital and acquired tibial deformities treated with either TSF (between 2014 and 2016) or Orthex (between 2017 and 2019) frames were included in a retrospective comparative study. Outcome measures were healing index, pin infection rate, regenerate quality and density, software residual rate, deformity correction accuracy, strut exchanges and quality of life (QoL). Results: The TSF group had 17 patients (18 frames) and the Orthex group had 21 patients (25 frames). The most common indications for tibial deformity correction were fibular hemimelia (14) and septic or traumatic growth arrest (8). The median time in frame was 230 days (TSF) versus 203 days (Orthex) (p= 0.06). The mean lengthening achieved was 54 mm (TSF) and 51 mm (Orthex) (p = 0.41). The healing index was 41 days/cm (TSF) versus 43 days/cm (Orthex) (p = 0.70). Pin site infections occurred more in the TSF cohort (40%) than in the Orthex cohort (18%) (p < 0.001). The regenerate in the Orthex group showed higher density at three months (p = 0.029) and was more homogenous (p = 0.023) at six months after frame application. Strut exchanges were less frequent with the Orthex system (p < 0.0001). QoL measures were similar in both cohorts (p = 0.92). Conclusions: This is the first study to compare two hexapod designs in paediatric orthopaedics. The Orthex system showed superiority in regenerate quality and a significant reduction in pin site infection rates. Both systems delivered predictable and accurate limb deformity correction. Level of evidence: III … (more)
- Is Part Of:
- Journal of children's orthopaedics. Volume 15:Number 2(2021)
- Journal:
- Journal of children's orthopaedics
- Issue:
- Volume 15:Number 2(2021)
- Issue Display:
- Volume 15, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 15
- Issue:
- 2
- Issue Sort Value:
- 2021-0015-0002-0000
- Page Start:
- 114
- Page End:
- 121
- Publication Date:
- 2021-04
- Subjects:
- limb reconstruction -- Taylor Spatial Frame -- Orthex frame -- tibia lengthening -- hexapod deformity correction
Pediatric orthopedics -- Periodicals
618.927005 - Journal URLs:
- http://link.springer.com/journal/11832 ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/842/ ↗
http://www.springerlink.com/content/120451/ ↗
https://online.boneandjoint.org.uk/toc/jco/current ↗
https://journals.sagepub.com/home/CHO ↗
http://www.springer.com/gb/ ↗ - DOI:
- 10.1302/1863-2548.15.200165 ↗
- Languages:
- English
- ISSNs:
- 1863-2521
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4957.960000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19273.xml