Mechanical, but not infective, pacemaker erosion may be successfully managed by re-implantation of pacemakers. Issue 2 (February 1994)
- Record Type:
- Journal Article
- Title:
- Mechanical, but not infective, pacemaker erosion may be successfully managed by re-implantation of pacemakers. Issue 2 (February 1994)
- Main Title:
- Mechanical, but not infective, pacemaker erosion may be successfully managed by re-implantation of pacemakers.
- Authors:
- Griffith, M. J.
Mounsey, J. P.
Bexton, R. S.
Holden, M. P. - Abstract:
- Abstract : OBJECTIVE--When a pacemaker box causes erosion it is usually removed and a new pacemaker implanted at a contralateral site. In this study when there was no evidence of systemic infection an attempt was made to clean and reimplant the same pacemaker in the same site. RESULTS--Over 10 years 62 patients had pacemaker reimplantation. In 18 patients the procedure was repeated a second time. Reimplantation was successful after at least six months follow up in 38 patients (61%): in nine two attempts had been made. Mean hospital stay for all patients was 21.3 days; for patients in whom the procedure was successful it was 12.5 days and for those in whom it was unsuccessful it was 35.4 days. 31 (82%) of the 38 patients in whom reimplantation was successful had no bacterial growth from wound swabs from 17/24 (71%) patients in whom reimplantation was unsuccessful (p < 0.001). Bacteria were grown from swabs from 7/8 patients with a protruding wire compared with 9/23 patients with a protruding pacemaker (p = 0.05). Thin patients and those who were older were more likely to have successful reimplantation: neither association reached statistical significance. A clinical impression of infection was not helpful. If re-implantation had been attempted only in the patients with negative wound swabs or intact skin the success rate would have been 74% at a cost of 5010 pounds per patient compared with a cost of 6509 pounds per patient for explantation and a reimplantation of a newAbstract : OBJECTIVE--When a pacemaker box causes erosion it is usually removed and a new pacemaker implanted at a contralateral site. In this study when there was no evidence of systemic infection an attempt was made to clean and reimplant the same pacemaker in the same site. RESULTS--Over 10 years 62 patients had pacemaker reimplantation. In 18 patients the procedure was repeated a second time. Reimplantation was successful after at least six months follow up in 38 patients (61%): in nine two attempts had been made. Mean hospital stay for all patients was 21.3 days; for patients in whom the procedure was successful it was 12.5 days and for those in whom it was unsuccessful it was 35.4 days. 31 (82%) of the 38 patients in whom reimplantation was successful had no bacterial growth from wound swabs from 17/24 (71%) patients in whom reimplantation was unsuccessful (p < 0.001). Bacteria were grown from swabs from 7/8 patients with a protruding wire compared with 9/23 patients with a protruding pacemaker (p = 0.05). Thin patients and those who were older were more likely to have successful reimplantation: neither association reached statistical significance. A clinical impression of infection was not helpful. If re-implantation had been attempted only in the patients with negative wound swabs or intact skin the success rate would have been 74% at a cost of 5010 pounds per patient compared with a cost of 6509 pounds per patient for explantation and a reimplantation of a new contralateral pacemaker. CONCLUSION--These data support the hypothesis that pacemaker erosion is caused by primary infection or by a non-infective process (probably mechanical pressure). Pacemaker erosion that is not caused by infection can be successfully managed by ipsilateral reimplantation and this approach saves money. … (more)
- Is Part Of:
- Heart. Volume 71:Issue 2(1994)
- Journal:
- Heart
- Issue:
- Volume 71:Issue 2(1994)
- Issue Display:
- Volume 71, Issue 2 (1994)
- Year:
- 1994
- Volume:
- 71
- Issue:
- 2
- Issue Sort Value:
- 1994-0071-0002-0000
- Page Start:
- 202
- Page End:
- 205
- Publication Date:
- 1994-02
- Subjects:
- Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/hrt.71.2.202 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19270.xml