Measurement of aortic regurgitation by Doppler echocardiography. Issue 1 (January 1986)
- Record Type:
- Journal Article
- Title:
- Measurement of aortic regurgitation by Doppler echocardiography. Issue 1 (January 1986)
- Main Title:
- Measurement of aortic regurgitation by Doppler echocardiography.
- Authors:
- Zhang, Y
Nitter-Hauge, S
Ihlen, H
Rootwelt, K
Myhre, E - Abstract:
- Abstract : In an attempt to develop a new approach to the non-invasive measurement of aortic regurgitation, transmitral volumetric flow (MF) and left ventricular total stroke volume (SV) were measured by Doppler and cross sectional echocardiography in 23 patients without aortic valve disease (group A) and in 26 patients with aortic regurgitation (group B). The transmitral volumetric flow was obtained by multiplying the corrected mitral orifice area by the diastolic velocity integral, and the left ventricular total stroke volume was derived by subtracting the left ventricular end systolic volume from the end diastolic volume. The aortic regurgitant fraction (RF) was calculated as: RF = 1 - MF/SV. In group A there was a close agreement between the transmitral volumetric flow and the left ventricular total stroke volume, and the difference between the two measurements did not differ significantly from zero. In group B the left ventricular total stroke volume was significantly larger than the transmitral volumetric flow, and there was good agreement between the regurgitant fractions determined by Doppler echocardiography and radionuclide ventriculography. Discrepancies between the two techniques were found in patients with combined aortic and mitral regurgitation or a low angiographic left ventricular ejection fraction (less than 35%). The effective cardiac output measured by Doppler echocardiography accorded well with that measured by the Fick method. Doppler echocardiographyAbstract : In an attempt to develop a new approach to the non-invasive measurement of aortic regurgitation, transmitral volumetric flow (MF) and left ventricular total stroke volume (SV) were measured by Doppler and cross sectional echocardiography in 23 patients without aortic valve disease (group A) and in 26 patients with aortic regurgitation (group B). The transmitral volumetric flow was obtained by multiplying the corrected mitral orifice area by the diastolic velocity integral, and the left ventricular total stroke volume was derived by subtracting the left ventricular end systolic volume from the end diastolic volume. The aortic regurgitant fraction (RF) was calculated as: RF = 1 - MF/SV. In group A there was a close agreement between the transmitral volumetric flow and the left ventricular total stroke volume, and the difference between the two measurements did not differ significantly from zero. In group B the left ventricular total stroke volume was significantly larger than the transmitral volumetric flow, and there was good agreement between the regurgitant fractions determined by Doppler echocardiography and radionuclide ventriculography. Discrepancies between the two techniques were found in patients with combined aortic and mitral regurgitation or a low angiographic left ventricular ejection fraction (less than 35%). The effective cardiac output measured by Doppler echocardiography accorded well with that measured by the Fick method. Doppler echocardiography provides a new and promising approach to the non-invasive measurement of aortic regurgitation. … (more)
- Is Part Of:
- Heart. Volume 55:Issue 1(1986)
- Journal:
- Heart
- Issue:
- Volume 55:Issue 1(1986)
- Issue Display:
- Volume 55, Issue 1 (1986)
- Year:
- 1986
- Volume:
- 55
- Issue:
- 1
- Issue Sort Value:
- 1986-0055-0001-0000
- Page Start:
- 32
- Page End:
- 38
- Publication Date:
- 1986-01
- Subjects:
- Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/hrt.55.1.32 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19261.xml