OC 8435 Multi-biomarker test strip for point-of-care screening for active tuberculosis: a five-country multi-centre test evaluation. (24th April 2019)
- Record Type:
- Journal Article
- Title:
- OC 8435 Multi-biomarker test strip for point-of-care screening for active tuberculosis: a five-country multi-centre test evaluation. (24th April 2019)
- Main Title:
- OC 8435 Multi-biomarker test strip for point-of-care screening for active tuberculosis: a five-country multi-centre test evaluation
- Authors:
- Corstjens, Paul
Hooij, Anouk Van
Tjon Kon Fat, Elisa
Herdigein, Shannon
Namuganga, Anna Ritah
Diergaardt, Azaria
Mutavhatsindi, Hygon
Gindeh, Awa
Mihret, Adane
Van De Spuy, Gian
Gunther, Gunar
Howe, Rawleigh
Mayanja-Kizza, Harriet
Sutherland, Jayne
Chegou, Novel N
Ottenhoff, Tom
Walzl, Gerhard
Geluk, Annemieke - Abstract:
- Abstract : Background: Inexpensive rapid screening tests that can be used at the point-of-care (POC) are vital to combat tuberculosis. Particularly, less invasive non-sputum-based biomarker tests for all TB forms can help controlling transmission. Availability of such tests would significantly accelerate and streamline diagnostic approaches, improve cost-efficiency and decrease unnecessary costly GeneXpert referrals. Methods: Multi-biomarker test (MBT) devices measuring levels of selections of up to six serum proteins simultaneously on a single lateral flow (LF) strip were produced. The strip contains individual capture lines for a biomarker selection allowing discrimination of TB-patients from other respiratory diseases (ORD). Only biomarkers successfully evaluated with singleplex strips (single biomarker tests) were applied to the MBT device. Quantitative signals are recorded with a low-cost handheld reader compatible with the applied luminescent up-converting particle (UCP) label. Biomarker selection and algorithms used to distinguish potential-TB and ORD are flexible. Results: Results obtained with MBT strips containing multiple test lines correlate well with singleplex LF strips. Using LF tests for 5 selected biomarkers a sensitivity of 94% and specificity of 96% could be achieved with a confirmed South African selection of 20 TB and 31 non-TB samples. Patients were designated TB positive when scoring a value above the cut-off threshold for at least 3 out of 5Abstract : Background: Inexpensive rapid screening tests that can be used at the point-of-care (POC) are vital to combat tuberculosis. Particularly, less invasive non-sputum-based biomarker tests for all TB forms can help controlling transmission. Availability of such tests would significantly accelerate and streamline diagnostic approaches, improve cost-efficiency and decrease unnecessary costly GeneXpert referrals. Methods: Multi-biomarker test (MBT) devices measuring levels of selections of up to six serum proteins simultaneously on a single lateral flow (LF) strip were produced. The strip contains individual capture lines for a biomarker selection allowing discrimination of TB-patients from other respiratory diseases (ORD). Only biomarkers successfully evaluated with singleplex strips (single biomarker tests) were applied to the MBT device. Quantitative signals are recorded with a low-cost handheld reader compatible with the applied luminescent up-converting particle (UCP) label. Biomarker selection and algorithms used to distinguish potential-TB and ORD are flexible. Results: Results obtained with MBT strips containing multiple test lines correlate well with singleplex LF strips. Using LF tests for 5 selected biomarkers a sensitivity of 94% and specificity of 96% could be achieved with a confirmed South African selection of 20 TB and 31 non-TB samples. Patients were designated TB positive when scoring a value above the cut-off threshold for at least 3 out of 5 biomarkers. Serum samples of potential TB patients collected at five medical research institutes (Ethiopia, Namibia, South Africa, The Gambia, Uganda) were tested locally with MBT strips comprised of CRP, SAA, IP-10, Ferritin, ApoA-I and IL-6 and results analysed to obtain an overall pan-Africa applicable signature. Conclusion: Evaluated POC applicable UCP-LF devices detecting serum biomarker signatures can help to distinguish active TB from other respiratory diseases and as such can prioritise highest-risk patients for further care. Ongoing prospective studies evaluate the MBT strip with fingerstick blood and do not require a laboratory or trained phlebotomist anymore. … (more)
- Is Part Of:
- BMJ global health. Volume 4(2019)Supplement 3
- Journal:
- BMJ global health
- Issue:
- Volume 4(2019)Supplement 3
- Issue Display:
- Volume 4, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 4
- Issue:
- 3
- Issue Sort Value:
- 2019-0004-0003-0000
- Page Start:
- A6
- Page End:
- A6
- Publication Date:
- 2019-04-24
- Subjects:
- World health -- Periodicals
362.105 - Journal URLs:
- http://www.bmj.com/archive ↗
http://gh.bmj.com/ ↗ - DOI:
- 10.1136/bmjgh-2019-EDC.14 ↗
- Languages:
- English
- ISSNs:
- 2059-7908
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19232.xml