Accuracy of staging in early oesophageal cancer using high resolution endoscopy and high resolution endosonography: a comparative, prospective, and blinded trial. Issue 5 (13th April 2004)
- Record Type:
- Journal Article
- Title:
- Accuracy of staging in early oesophageal cancer using high resolution endoscopy and high resolution endosonography: a comparative, prospective, and blinded trial. Issue 5 (13th April 2004)
- Main Title:
- Accuracy of staging in early oesophageal cancer using high resolution endoscopy and high resolution endosonography: a comparative, prospective, and blinded trial
- Authors:
- May, A
Günter, E
Roth, F
Gossner, L
Stolte, M
Vieth, M
Ell, C - Abstract:
- Abstract : Background and aims: The increasing use of endoscopic resection for curative treatment of early oesophageal cancers requires accurate staging before therapy. In a prospective blinded trial, we compared staging of early oesophageal carcinoma using high resolution endoscopy (HR-E) with staging using high resolution endosonography (HR-EUS). Patients and methods: A total of 100 patients (89 men, 11 women; mean age 63.9 (10.8) years (range 31–91)) with a suspicion of early oesophageal adenocarcinoma (n = 81) or squamous cell carcinoma (n = 19) were enrolled in the study. After endoscopic staging with high resolution video endoscopy by two experienced endoscopists, HR-EUS was performed by an experienced endosonographer who was blinded to the endoscopic assessment. Results of the staging examinations were correlated with the histology of the resected tumours. Results: Overall rates for accuracy of the endoscopic and endosonographic staging were 83.4% and 79.6%, respectively. Sensitivity for mucosal tumours (n = 68) was more than 90% (EUS 91.2%, endoscopy 94.1%) while sensitivity for submucosal tumours (n = 25) was lower, at 48% for EUS and 56% for endoscopic staging. A combination of the two techniques increased the sensitivity for submucosal tumours to 60%. Submucosal tumours in the tubular oesophagus were significantly better staged with HR-EUS than submucosal tumours close to the oesophagogastric junction (10/11 v 2/14; p<0.001). Tumours infiltrating the second andAbstract : Background and aims: The increasing use of endoscopic resection for curative treatment of early oesophageal cancers requires accurate staging before therapy. In a prospective blinded trial, we compared staging of early oesophageal carcinoma using high resolution endoscopy (HR-E) with staging using high resolution endosonography (HR-EUS). Patients and methods: A total of 100 patients (89 men, 11 women; mean age 63.9 (10.8) years (range 31–91)) with a suspicion of early oesophageal adenocarcinoma (n = 81) or squamous cell carcinoma (n = 19) were enrolled in the study. After endoscopic staging with high resolution video endoscopy by two experienced endoscopists, HR-EUS was performed by an experienced endosonographer who was blinded to the endoscopic assessment. Results of the staging examinations were correlated with the histology of the resected tumours. Results: Overall rates for accuracy of the endoscopic and endosonographic staging were 83.4% and 79.6%, respectively. Sensitivity for mucosal tumours (n = 68) was more than 90% (EUS 91.2%, endoscopy 94.1%) while sensitivity for submucosal tumours (n = 25) was lower, at 48% for EUS and 56% for endoscopic staging. A combination of the two techniques increased the sensitivity for submucosal tumours to 60%. Submucosal tumours in the tubular oesophagus were significantly better staged with HR-EUS than submucosal tumours close to the oesophagogastric junction (10/11 v 2/14; p<0.001). Tumours infiltrating the second and third submucosal layers were also more correctly diagnosed than tumours with slight infiltration of the first submucosal layer (sm1). Conclusions: The overall diagnostic accuracy of both HR-E and HR-EUS with a 20 MHz miniprobe in early oesophageal cancer was high (approximately 80%), with no significant differences between the two techniques. HR-E and HR-EUS provide a high level of diagnostic accuracy for mucosal tumours and submucosal tumours located in the tubular part of the oesophagus. With submucosal tumours located at the oesophagogastric junction or with infiltration of the first third of the submucosa however, the diagnostic accuracy of both techniques is not yet satisfactory. … (more)
- Is Part Of:
- Gut. Volume 53:Issue 5(2004)
- Journal:
- Gut
- Issue:
- Volume 53:Issue 5(2004)
- Issue Display:
- Volume 53, Issue 5 (2004)
- Year:
- 2004
- Volume:
- 53
- Issue:
- 5
- Issue Sort Value:
- 2004-0053-0005-0000
- Page Start:
- 634
- Page End:
- 640
- Publication Date:
- 2004-04-13
- Subjects:
- early oesophageal cancer -- endosonographic staging -- high resolution endosonography -- endoscopic staging
EUS, endosonography -- HR-E, high resolution endoscopy -- HR-EUS, high resolution endosonography
Gastroenterology -- Periodicals
616.33 - Journal URLs:
- http://gut.bmjjournals.com ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/gut.2003.029421 ↗
- Languages:
- English
- ISSNs:
- 0017-5749
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19192.xml