0191 Are indoor concentrations of airborne mould spores in non-industrial environments sufficiently high to cause hypersensitivity pneumonitis?. (23rd June 2014)
- Record Type:
- Journal Article
- Title:
- 0191 Are indoor concentrations of airborne mould spores in non-industrial environments sufficiently high to cause hypersensitivity pneumonitis?. (23rd June 2014)
- Main Title:
- 0191 Are indoor concentrations of airborne mould spores in non-industrial environments sufficiently high to cause hypersensitivity pneumonitis?
- Authors:
- Kolstad, Henrik A
Skov, Simon
Malling, Tine Birgitte Halsen
Bendstrup, Elisabeth
Schlünssen, Vivi - Abstract:
- Abstract : Objectives: Antigen exposure is the only diagnostic criteria specific for hypersensitivity pneumonitis (HP) compared with other interstitial lung diseases. Indoor mould exposure in non-industrial environments has been claimed to cause HP, but little is known about exposure levels. Our objective was to compare indoor concentrations of airborne mould spores for patients diagnosed with indoor HP with background levels and levels measured for patients diagnosed with farmers' lung and suberosis. Method: We included 8 patients diagnosed with HP based on characteristic clinical findings, signs of indoor mould growth at home or at their non-industrial work place, and increased levels of precipitating antibodies for moulds. We collected 110 air samples from all affected rooms, adjacent rooms, and outdoor. Results: The average total spore concentrations varied between 22 000 and 36 000 spores per m 3, and the average viable concentrations between 35 CFU/m 3 and 457 CFU/m 3, with no clear association between spore concentration and affected rooms, adjacent rooms and outdoor. Conclusions: The observed levels did not exceed usual indoor and outdoor levels and were orders of magnitude below levels measured for patients diagnosed with farmers' lung and suberosis, and we question if indoor mould levels in non-industrial environments are sufficient to cause HP. Relying solely on signs of moulds or presence of precipitating antibodies when diagnosing HP may cause other interstitialAbstract : Objectives: Antigen exposure is the only diagnostic criteria specific for hypersensitivity pneumonitis (HP) compared with other interstitial lung diseases. Indoor mould exposure in non-industrial environments has been claimed to cause HP, but little is known about exposure levels. Our objective was to compare indoor concentrations of airborne mould spores for patients diagnosed with indoor HP with background levels and levels measured for patients diagnosed with farmers' lung and suberosis. Method: We included 8 patients diagnosed with HP based on characteristic clinical findings, signs of indoor mould growth at home or at their non-industrial work place, and increased levels of precipitating antibodies for moulds. We collected 110 air samples from all affected rooms, adjacent rooms, and outdoor. Results: The average total spore concentrations varied between 22 000 and 36 000 spores per m 3, and the average viable concentrations between 35 CFU/m 3 and 457 CFU/m 3, with no clear association between spore concentration and affected rooms, adjacent rooms and outdoor. Conclusions: The observed levels did not exceed usual indoor and outdoor levels and were orders of magnitude below levels measured for patients diagnosed with farmers' lung and suberosis, and we question if indoor mould levels in non-industrial environments are sufficient to cause HP. Relying solely on signs of moulds or presence of precipitating antibodies when diagnosing HP may cause other interstitial lung diseases to be overseen and patients may take initiatives such as quitting the job or leaving their homes that will not alleviate their disease but have significant social consequences. … (more)
- Is Part Of:
- Occupational and environmental medicine. Volume 71(2014)Supplement 1
- Journal:
- Occupational and environmental medicine
- Issue:
- Volume 71(2014)Supplement 1
- Issue Display:
- Volume 71, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 71
- Issue:
- 1
- Issue Sort Value:
- 2014-0071-0001-0000
- Page Start:
- A85
- Page End:
- A85
- Publication Date:
- 2014-06-23
- Subjects:
- Medicine, Industrial -- Periodicals
Environmental health -- Periodicals
616.980305 - Journal URLs:
- http://oem.bmj.com/ ↗
http://www.jstor.org/journals/13510711.html ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=172&action=archive ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/oemed-2014-102362.265 ↗
- Languages:
- English