Simulation study of frequency control characteristics of a generation III + nuclear power plant. (May 2018)
- Record Type:
- Journal Article
- Title:
- Simulation study of frequency control characteristics of a generation III + nuclear power plant. (May 2018)
- Main Title:
- Simulation study of frequency control characteristics of a generation III + nuclear power plant
- Authors:
- Wang, Pengfei
Fu, Yan
Wei, Xinyu
Zhao, Fuyu - Abstract:
- Highlights: A full-scope frequency control simulation and analysis platform for AP1000 is developed in Simulink. Frequency control transients of AP1000 during entire life cycle were simulated and analyzed. Load follow capability, economy and safety of AP1000 during these transients were studied qualitatively. Impact of key parameters on system responses and grid frequency was studied with recommended values given. Abstract: The AP1000, as an advanced Generation III + pressurized water reactor (PWR) nuclear power plant (NPP), is designed to have better transient response capability, higher security and economy compared with the traditional Generation II PWR NPPs. This is partly due to the implementation of the advanced Mechanical Shim (MSHIM) core control strategy that eliminates the need for boron concentration adjustments during load follow operations. Since the world's first AP1000 NPP is still under construction, there is no actual operating experience and data. This paper studies the dynamic responses and control characteristics of the AP1000 NPP during frequency control transients by modeling and simulation. First, a complete set of nonlinear mathematical models for the AP1000 NPP, including those of the nuclear steam supply system (NSSS) and balance of plant (BOP) system, was established. The S-function modules for these mathematical models and the modules of corresponding control systems were developed in MATLAB/Simulink. Then, by coupling all the modules according toHighlights: A full-scope frequency control simulation and analysis platform for AP1000 is developed in Simulink. Frequency control transients of AP1000 during entire life cycle were simulated and analyzed. Load follow capability, economy and safety of AP1000 during these transients were studied qualitatively. Impact of key parameters on system responses and grid frequency was studied with recommended values given. Abstract: The AP1000, as an advanced Generation III + pressurized water reactor (PWR) nuclear power plant (NPP), is designed to have better transient response capability, higher security and economy compared with the traditional Generation II PWR NPPs. This is partly due to the implementation of the advanced Mechanical Shim (MSHIM) core control strategy that eliminates the need for boron concentration adjustments during load follow operations. Since the world's first AP1000 NPP is still under construction, there is no actual operating experience and data. This paper studies the dynamic responses and control characteristics of the AP1000 NPP during frequency control transients by modeling and simulation. First, a complete set of nonlinear mathematical models for the AP1000 NPP, including those of the nuclear steam supply system (NSSS) and balance of plant (BOP) system, was established. The S-function modules for these mathematical models and the modules of corresponding control systems were developed in MATLAB/Simulink. Then, by coupling all the modules according to the "reactor-following-turbine" operation mode, a full-scope, dynamic simulation platform of the AP1000 NPP was developed. After validation of the platform against the best-estimate analysis code CENTS developed by the Westinghouse under two typical 10% of full power (FP) step load change transients, it was used for the dynamic simulation and study of frequency control characteristics of the AP1000 NPP. Typical frequency control transients with ± 3%FP step load changes in power grid were simulated. Dynamic responses of key parameters of the NSSS and BOP system were presented and studied to assess and evaluate the load follow capability, economy and safety of the AP1000 NPP during these transients. Moreover, the impact of key primary frequency control parameters on the dynamic response characteristics of the AP1000 NPP and the control effect of system frequency was also studied, and the recommended values of the frequency deadband and bias coefficient have been given for the world's first AP1000 NPP under construction in Sanmen, Zhejiang province of China. The simulation and analysis results in the present study contribute to the digestion and absorption of the frequency control characteristics of the AP1000 and can also offer certain guidance for the engineering practice. … (more)
- Is Part Of:
- Annals of nuclear energy. Volume 115(2018)
- Journal:
- Annals of nuclear energy
- Issue:
- Volume 115(2018)
- Issue Display:
- Volume 115, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 115
- Issue:
- 2018
- Issue Sort Value:
- 2018-0115-2018-0000
- Page Start:
- 502
- Page End:
- 522
- Publication Date:
- 2018-05
- Subjects:
- AP1000 -- Mathematical modeling -- Dynamic simulation -- Frequency control
Nuclear energy -- Periodicals
Nuclear engineering -- Periodicals
621.4805 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03064549 ↗
http://catalog.hathitrust.org/api/volumes/oclc/2243298.html ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.anucene.2018.02.014 ↗
- Languages:
- English
- ISSNs:
- 0306-4549
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1043.150000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19207.xml