Influence of noninvasive central blood pressure devices for afterload monitoring with aortic velocity-pressure Loop in anesthetized patients. Issue 4 (August 2020)
- Record Type:
- Journal Article
- Title:
- Influence of noninvasive central blood pressure devices for afterload monitoring with aortic velocity-pressure Loop in anesthetized patients. Issue 4 (August 2020)
- Main Title:
- Influence of noninvasive central blood pressure devices for afterload monitoring with aortic velocity-pressure Loop in anesthetized patients
- Authors:
- Leve, Charlotte
Hong, Alex
Millasseau, Sandrine
Joachim, Jona
Touchard, Cyril
Mateo, Joaquim
Serrano, José
Mebazaa, Alexandre
Gayat, Etienne
Vallee, Fabrice - Abstract:
- Abstract : Background: Global afterload angle (GALA) is a parameter derived from velocity-pressure loop (VP Loop), for continuous assessment of cardiac afterload in the operating room. It has been validated with invasive measure of central pressure. The aim of this study was to evaluate the feasibility of noninvasive VP Loop obtained with central pressure measured with two different noninvasive tonometers. Methods: A prospective, observational, monocentric study was conducted in 51 patients under general anesthesia. Invasive central pressure (cPINV ) was measured with a fulfilled intravascular catheter, and noninvasive central pressure signals were obtained with two applanation tonometry devices: radial artery tonometry (cPSHYG : Sphygmocor tonometer) and carotid tonometry (cPCOMP : Complior tonometer). Three VP Loops were built: VP LoopINV, VP LoopSPHYG and VP LoopCOMP . Patients were separated according to cardiovascular risk factors. Results: In the 51 patients under general anesthesia, cPSHYG was adequately obtained in 48 patients (89%) but, compared to cPINV, SBP was underestimated (−4 ± 6 mmHg, P < 0.0001), augmentation index (AIXSPHYG ) and a GALASPHYG were overestimated (+13 ± 19%, P = 0.0077 and +4 ± 8°, P = 0.0024, respectively) with large limit of agreement (LOA) (−21 to 47% and −13 to 21° for AIXSPHYG and GALASPHYG, respectively). With the Complior, the failure rate of measurement for cPCOMP was 41%. SBP was similar (3 ± 17 mmHg, P = 0.32), AIXCOMP wasAbstract : Background: Global afterload angle (GALA) is a parameter derived from velocity-pressure loop (VP Loop), for continuous assessment of cardiac afterload in the operating room. It has been validated with invasive measure of central pressure. The aim of this study was to evaluate the feasibility of noninvasive VP Loop obtained with central pressure measured with two different noninvasive tonometers. Methods: A prospective, observational, monocentric study was conducted in 51 patients under general anesthesia. Invasive central pressure (cPINV ) was measured with a fulfilled intravascular catheter, and noninvasive central pressure signals were obtained with two applanation tonometry devices: radial artery tonometry (cPSHYG : Sphygmocor tonometer) and carotid tonometry (cPCOMP : Complior tonometer). Three VP Loops were built: VP LoopINV, VP LoopSPHYG and VP LoopCOMP . Patients were separated according to cardiovascular risk factors. Results: In the 51 patients under general anesthesia, cPSHYG was adequately obtained in 48 patients (89%) but, compared to cPINV, SBP was underestimated (−4 ± 6 mmHg, P < 0.0001), augmentation index (AIXSPHYG ) and a GALASPHYG were overestimated (+13 ± 19%, P = 0.0077 and +4 ± 8°, P = 0.0024, respectively) with large limit of agreement (LOA) (−21 to 47% and −13 to 21° for AIXSPHYG and GALASPHYG, respectively). With the Complior, the failure rate of measurement for cPCOMP was 41%. SBP was similar (3 ± 17 mmHg, P = 0.32), AIXCOMP was underestimated (−11 ± 19%, P = 0.0046) and GALACOMP was similar but with large LOA (−50 to 26% and −20 to 18° for AIXCOMP and GALACOMP, respectively). Conclusion: In anesthetized patient, the reliability of noninvasive central pressure monitoring by tonometry seems too limited to monitor cardiac afterload with VP Loop. … (more)
- Is Part Of:
- Blood pressure monitoring. Volume 25:Issue 4(2020)
- Journal:
- Blood pressure monitoring
- Issue:
- Volume 25:Issue 4(2020)
- Issue Display:
- Volume 25, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 25
- Issue:
- 4
- Issue Sort Value:
- 2020-0025-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-08
- Subjects:
- blood pressure monitoring -- cardiac afterload -- general anesthesia -- hemodynamic -- tonometry -- velocity pressure loop
Blood pressure -- Measurement -- Periodicals
Blood Pressure Determination -- Periodicals
Blood Pressure Monitoring, Ambulatory -- Periodicals
Blood Pressure Monitors -- Periodicals
Hypertension -- Periodicals
612.140287 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00126097-000000000-00000&NEWS=N ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00126097-000000000-00000 ↗
http://www.bpmonitoring.com/ ↗
http://journals.lww.com/pages/default.aspx ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1097/MBP.0000000000000445 ↗
- Languages:
- English
- ISSNs:
- 1359-5237
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2113.035500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19152.xml