Neonatal Nurse Practitioner Use of Ultrasonography to Verify Umbilical Venous Catheter Placement in the Neonatal Intensive Care Unit. (August 2020)
- Record Type:
- Journal Article
- Title:
- Neonatal Nurse Practitioner Use of Ultrasonography to Verify Umbilical Venous Catheter Placement in the Neonatal Intensive Care Unit. (August 2020)
- Main Title:
- Neonatal Nurse Practitioner Use of Ultrasonography to Verify Umbilical Venous Catheter Placement in the Neonatal Intensive Care Unit
- Authors:
- Mele, Robert
Panesar, Laurie E.
Heyden, Marybeth
Sridhar, Shanthy
Brandon, Debra - Other Names:
- Samra Haifa A. section editor.
- Abstract:
- Abstract : Background: Literature dating back to 1982 supports the use of ultrasound to confirm UVC position as a more reliable method compared to x-ray. The use of ultrasound to confirm UVC position remains infrequent in the NICU. Purpose: To determine the feasibility of training an NNP in the acquisition and interpretation of a parasternal short-axis (PSAX) image of the heart to confirm UVC position. Methods: A retrospective review of 48 charts evaluated descriptive data using standard technique of an x-ray to confirm UVC placement. An NNP was trained to acquire and interpret a parasternal short-axis (PSAX) cardiac view by a pediatric cardiologist. The NNP independently and prospectively evaluated 21 neonates and determined whether the UVC was in satisfactory or unsatisfactory position. The same image was blindly over-read by the pediatric cardiologist. Agreement between the NNP and pediatric cardiologist interpretations as well as the pediatric cardiologist and radiologist interpretations was evaluated using the κ-test. Results: Initial pediatric cardiology interpretation of UVC position showed the UVC to be malpositioned in 66% of neonates (n = 14). NNP and pediatric cardiology interpretations in UVC position had 86% agreement (κ-0.667). Pediatric cardiology (ultrasound) and radiology interpretations (x-ray) in UVC position had 86% agreement (κ-0.69). Implications for Practice: It is feasible to train NNPs to perform and accurately interpret a single PSAX ultrasoundAbstract : Background: Literature dating back to 1982 supports the use of ultrasound to confirm UVC position as a more reliable method compared to x-ray. The use of ultrasound to confirm UVC position remains infrequent in the NICU. Purpose: To determine the feasibility of training an NNP in the acquisition and interpretation of a parasternal short-axis (PSAX) image of the heart to confirm UVC position. Methods: A retrospective review of 48 charts evaluated descriptive data using standard technique of an x-ray to confirm UVC placement. An NNP was trained to acquire and interpret a parasternal short-axis (PSAX) cardiac view by a pediatric cardiologist. The NNP independently and prospectively evaluated 21 neonates and determined whether the UVC was in satisfactory or unsatisfactory position. The same image was blindly over-read by the pediatric cardiologist. Agreement between the NNP and pediatric cardiologist interpretations as well as the pediatric cardiologist and radiologist interpretations was evaluated using the κ-test. Results: Initial pediatric cardiology interpretation of UVC position showed the UVC to be malpositioned in 66% of neonates (n = 14). NNP and pediatric cardiology interpretations in UVC position had 86% agreement (κ-0.667). Pediatric cardiology (ultrasound) and radiology interpretations (x-ray) in UVC position had 86% agreement (κ-0.69). Implications for Practice: It is feasible to train NNPs to perform and accurately interpret a single PSAX ultrasound image to determine satisfactory UVC position. Implications for Research: Increasing the use of ultrasound to determine satisfactory position of UVCs in the NICU can reduce unnecessary exposure to ionizing radiation in neonates. … (more)
- Is Part Of:
- Advances in neonatal care. Volume 20:Number 4(2020)
- Journal:
- Advances in neonatal care
- Issue:
- Volume 20:Number 4(2020)
- Issue Display:
- Volume 20, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 20
- Issue:
- 4
- Issue Sort Value:
- 2020-0020-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-08
- Subjects:
- neonatal nurse practitioner -- ultrasonography -- umbilical venous catheter
Newborn infants -- Medical care -- Periodicals
Newborn infants -- Diseases -- Nursing -- Periodicals
Premature infants -- Hospital care -- Periodicals
618.9201 - Journal URLs:
- http://www.advancesinneonatalcare.org ↗
http://www.sciencedirect.com/science/journal/15360903 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ANC.0000000000000708 ↗
- Languages:
- English
- ISSNs:
- 1536-0903
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0709.463000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19145.xml