Measurement of In Vivo Biomechanical Changes Attributable to Epithelial Removal in Keratoconus Using a Noncontact Tonometer. Issue 8 (August 2020)
- Record Type:
- Journal Article
- Title:
- Measurement of In Vivo Biomechanical Changes Attributable to Epithelial Removal in Keratoconus Using a Noncontact Tonometer. Issue 8 (August 2020)
- Main Title:
- Measurement of In Vivo Biomechanical Changes Attributable to Epithelial Removal in Keratoconus Using a Noncontact Tonometer
- Authors:
- Ziaei, Mohammed
Gokul, Akilesh
Vellara, Hans
Lu, Lucy M.
Patel, Dipika V.
McGhee, Charles N. J. - Abstract:
- Abstract : Purpose: To compare the biomechanical properties of the cornea after epithelial removal in eyes with keratoconus undergoing corneal cross-linking. Methods: Prospective interventional case series at a university hospital tertiary referral center. Corneal biomechanical properties were measured in patients with keratoconus undergoing corneal cross-linking, immediately before and after epithelial debridement by using a dynamic ultrahigh-speed Scheimpflug camera equipped with a noncontact tonometer. Results: The study comprised 45 eyes of 45 patients with a mean age of 19.6 ± 4.9 years (range 14–34). The cornea was found to be 23.7 ± 15.7 μm thinner after epithelial removal ( P < 0.01). Corneal stiffness was reduced after epithelial removal as demonstrated by a significant decrease of parameters such as stiffness parameter A1 (12.31, P < 0.01), stiffness parameter-highest concavity (2.25, P < 0.01), A1 length (0.13 mm, P = 0.04), highest concavity radius of curvature (0.26 mm, P = 0.01), highest concavity time (0.22 ms, P = 0.04) and an increase in A1 velocity (−0.01 m/s, P = 0.01), A1 deformation amplitude (−0.03 mm, P ⩽ 0.01), A1 deflection length (−0.32 mm, P < 0.01), A2 deformation amplitude (−0.03 mm, P = 0.01), and A2 deflection length (−1.00 mm, P < 0.01). There were no significant differences in biomechanical intraocular pressure (0.15 mm Hg, P = 0.78), deformation amplitude (0.03, P = 0.54), maximum inverse radius (−0.01 mm, P = 0.57), and whole eye movementAbstract : Purpose: To compare the biomechanical properties of the cornea after epithelial removal in eyes with keratoconus undergoing corneal cross-linking. Methods: Prospective interventional case series at a university hospital tertiary referral center. Corneal biomechanical properties were measured in patients with keratoconus undergoing corneal cross-linking, immediately before and after epithelial debridement by using a dynamic ultrahigh-speed Scheimpflug camera equipped with a noncontact tonometer. Results: The study comprised 45 eyes of 45 patients with a mean age of 19.6 ± 4.9 years (range 14–34). The cornea was found to be 23.7 ± 15.7 μm thinner after epithelial removal ( P < 0.01). Corneal stiffness was reduced after epithelial removal as demonstrated by a significant decrease of parameters such as stiffness parameter A1 (12.31, P < 0.01), stiffness parameter-highest concavity (2.25, P < 0.01), A1 length (0.13 mm, P = 0.04), highest concavity radius of curvature (0.26 mm, P = 0.01), highest concavity time (0.22 ms, P = 0.04) and an increase in A1 velocity (−0.01 m/s, P = 0.01), A1 deformation amplitude (−0.03 mm, P ⩽ 0.01), A1 deflection length (−0.32 mm, P < 0.01), A2 deformation amplitude (−0.03 mm, P = 0.01), and A2 deflection length (−1.00 mm, P < 0.01). There were no significant differences in biomechanical intraocular pressure (0.15 mm Hg, P = 0.78), deformation amplitude (0.03, P = 0.54), maximum inverse radius (−0.01 mm, P = 0.57), and whole eye movement length (−0.02 mm, P = 0.12). Conclusions: Dynamic ultrahigh-speed Scheimpflug camera equipped with a noncontact tonometer offers an alternative method for in vivo measurements of the epithelial layer's contribution to corneal biomechanical properties. Our results suggest that corneal epithelium may play a more significant role in corneal biomechanical properties in patients with keratoconus than previously described. … (more)
- Is Part Of:
- Cornea. Volume 39:Issue 8(2020)
- Journal:
- Cornea
- Issue:
- Volume 39:Issue 8(2020)
- Issue Display:
- Volume 39, Issue 8 (2020)
- Year:
- 2020
- Volume:
- 39
- Issue:
- 8
- Issue Sort Value:
- 2020-0039-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-08
- Subjects:
- cornea -- epithelium -- Bowman layer -- keratoconus -- biomechanics -- collagen cross-linking
Cornea -- Periodicals
Cornea -- Periodicals
Cornée -- Périodiques
617.719 - Journal URLs:
- http://journals.lww.com/corneajrnl/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICO.0000000000002344 ↗
- Languages:
- English
- ISSNs:
- 0277-3740
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3470.927500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19145.xml