Semi‐automated von Willebrand factor multimer assay for von Willebrand disease: Further validation, benefits and limitations. (11th September 2019)
- Record Type:
- Journal Article
- Title:
- Semi‐automated von Willebrand factor multimer assay for von Willebrand disease: Further validation, benefits and limitations. (11th September 2019)
- Main Title:
- Semi‐automated von Willebrand factor multimer assay for von Willebrand disease: Further validation, benefits and limitations
- Authors:
- Oliver, Susan
Vanniasinkam, Thiru
Mohammed, Soma
Vong, Ronny
Favaloro, Emmanuel J. - Abstract:
- Abstract: Introduction: Accurate diagnosis of von Willebrand disease (VWD) enables effective patient management. von Willebrand factor (VWF) multimer analysis provides useful information regarding VWF multimer structure, thereby aiding VWD subtyping and management; however, historically technically challenging assays have had limited utility. This study evaluates the Sebia Hydrasys Hydragel‐11 semi‐automated VWF multimer assay and further validates the Hydragel‐5 gel system, as primarily pertaining to VWD diagnostics and monitoring of therapy. Methods: Provisionally diagnosed (via a reference assay test panel) archived patient samples and prospective test patient samples, including those undergoing desmopressin trial or therapy monitoring, along with commercial and in‐house control material and various external quality assessment (EQA) samples, were analysed. VWF multimers were evaluated for presence, loss or partial loss of high molecular weight (HMWM) and intermediate molecular weight (IMWM) multimers by both visual inspection and densitometric scanning, and comparison with reference assay results. Results: All anticipated multimer patterns were reproduced, with patients generally showing multimer profiles matching expected patterns according to VWD type based on reference test panel 'diagnosis'. Occasional discrepancies were resolved by retesting. The increase in plasma VWF following desmopressin therapy was also clearly demonstrated. Multimer profiles of EQA samplesAbstract: Introduction: Accurate diagnosis of von Willebrand disease (VWD) enables effective patient management. von Willebrand factor (VWF) multimer analysis provides useful information regarding VWF multimer structure, thereby aiding VWD subtyping and management; however, historically technically challenging assays have had limited utility. This study evaluates the Sebia Hydrasys Hydragel‐11 semi‐automated VWF multimer assay and further validates the Hydragel‐5 gel system, as primarily pertaining to VWD diagnostics and monitoring of therapy. Methods: Provisionally diagnosed (via a reference assay test panel) archived patient samples and prospective test patient samples, including those undergoing desmopressin trial or therapy monitoring, along with commercial and in‐house control material and various external quality assessment (EQA) samples, were analysed. VWF multimers were evaluated for presence, loss or partial loss of high molecular weight (HMWM) and intermediate molecular weight (IMWM) multimers by both visual inspection and densitometric scanning, and comparison with reference assay results. Results: All anticipated multimer patterns were reproduced, with patients generally showing multimer profiles matching expected patterns according to VWD type based on reference test panel 'diagnosis'. Occasional discrepancies were resolved by retesting. The increase in plasma VWF following desmopressin therapy was also clearly demonstrated. Multimer profiles of EQA samples complemented reference test panel results and matched EQA targets. There were some 'technical' limitations noted. Conclusion: This easy to use, standardised, semi‐automated multimer analysis system can demonstrate the multimer profile of VWD patients, thus representing an additional laboratory tool for improved diagnosis, thereby facilitating appropriate patient management. … (more)
- Is Part Of:
- International journal of laboratory hematology. Volume 41:Number 6(2019:Dec.)
- Journal:
- International journal of laboratory hematology
- Issue:
- Volume 41:Number 6(2019:Dec.)
- Issue Display:
- Volume 41, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 41
- Issue:
- 6
- Issue Sort Value:
- 2019-0041-0006-0000
- Page Start:
- 762
- Page End:
- 771
- Publication Date:
- 2019-09-11
- Subjects:
- desmopressin -- Hydragel -- Multimers -- von Willebrand disease -- von Willebrand factor
Hematology -- Periodicals
Blood -- Diseases -- Periodicals
Hematology -- Periodicals
616.15005 - Journal URLs:
- http://firstsearch.oclc.org/FSIP?db=ECO&journal=1751-5521&screen=info&done=referer ↗
http://www.blackwell-synergy.com/loi/clh ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1751-553X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ijlh.13107 ↗
- Languages:
- English
- ISSNs:
- 1751-5521
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.312220
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19158.xml