Feasibility of a real-time self-monitoring device for sitting less and moving more: a randomised controlled trial. Issue 1 (11th October 2017)
- Record Type:
- Journal Article
- Title:
- Feasibility of a real-time self-monitoring device for sitting less and moving more: a randomised controlled trial. Issue 1 (11th October 2017)
- Main Title:
- Feasibility of a real-time self-monitoring device for sitting less and moving more: a randomised controlled trial
- Authors:
- Martin, Anne
Adams, Jacob M
Bunn, Christopher
Gill, Jason M R
Gray, Cindy M
Hunt, Kate
Maxwell, Douglas J
van der Ploeg, Hidde P
Wyke, Sally
Mutrie, Nanette - Abstract:
- Abstract : Objectives: Time spent inactive and sedentary are both associated with poor health. Self-monitoring of walking, using pedometers for real-time feedback, is effective at increasing physical activity. This study evaluated the feasibility of a new pocket-worn sedentary time and physical activity real-time self-monitoring device (SitFIT). Methods: Forty sedentary men were equally randomised into two intervention groups. For 4 weeks, one group received a SitFIT providing feedback on steps and time spent sedentary (lying/sitting); the other group received a SitFIT providing feedback on steps and time spent upright (standing/stepping). Change in sedentary time, standing time, stepping time and step count was assessed using activPAL monitors at baseline, 4-week follow-up (T1) and 12-week (T2) follow-up. Semistructured interviews were conducted after 4 and 12 weeks. Results: The SitFIT was reported as acceptable and usable and seen as a motivating tool to reduce sedentary time by both groups. On average, participants reduced their sedentary time by 7.8 minutes/day (95% CI −55.4 to 39.7) (T1) and by 8.2 minutes/day (95% CI −60.1 to 44.3) (T2). They increased standing time by 23.2 minutes/day (95% CI 4.0 to 42.5) (T1) and 16.2 minutes/day (95% CI −13.9 to 46.2) (T2). Stepping time was increased by 8.5 minutes/day (95% CI 0.9 to 16.0) (T1) and 9.0 minutes/day (95% CI 0.5 to 17.5) (T2). There were no between-group differences at either follow-up time points. Conclusion: TheAbstract : Objectives: Time spent inactive and sedentary are both associated with poor health. Self-monitoring of walking, using pedometers for real-time feedback, is effective at increasing physical activity. This study evaluated the feasibility of a new pocket-worn sedentary time and physical activity real-time self-monitoring device (SitFIT). Methods: Forty sedentary men were equally randomised into two intervention groups. For 4 weeks, one group received a SitFIT providing feedback on steps and time spent sedentary (lying/sitting); the other group received a SitFIT providing feedback on steps and time spent upright (standing/stepping). Change in sedentary time, standing time, stepping time and step count was assessed using activPAL monitors at baseline, 4-week follow-up (T1) and 12-week (T2) follow-up. Semistructured interviews were conducted after 4 and 12 weeks. Results: The SitFIT was reported as acceptable and usable and seen as a motivating tool to reduce sedentary time by both groups. On average, participants reduced their sedentary time by 7.8 minutes/day (95% CI −55.4 to 39.7) (T1) and by 8.2 minutes/day (95% CI −60.1 to 44.3) (T2). They increased standing time by 23.2 minutes/day (95% CI 4.0 to 42.5) (T1) and 16.2 minutes/day (95% CI −13.9 to 46.2) (T2). Stepping time was increased by 8.5 minutes/day (95% CI 0.9 to 16.0) (T1) and 9.0 minutes/day (95% CI 0.5 to 17.5) (T2). There were no between-group differences at either follow-up time points. Conclusion: The SitFIT was perceived as a useful tool for self-monitoring of sedentary time. It has potential as a real-time self-monitoring device to reduce sedentary and increase upright time. … (more)
- Is Part Of:
- BMJ open sport & exercise medicine. Volume 3:Issue 1(2017)
- Journal:
- BMJ open sport & exercise medicine
- Issue:
- Volume 3:Issue 1(2017)
- Issue Display:
- Volume 3, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 3
- Issue:
- 1
- Issue Sort Value:
- 2017-0003-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-10-11
- Subjects:
- sedentary behaviour -- sitting -- self-monitoring -- device -- user trial -- feasibility -- SitFIT
Sports medicine -- Periodicals
Exercise therapy -- Periodicals
617.102705 - Journal URLs:
- http://www.bmj.com/archive ↗
http://bmjopensem.bmj.com/ ↗ - DOI:
- 10.1136/bmjsem-2017-000285 ↗
- Languages:
- English
- ISSNs:
- 2055-7647
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19161.xml