Indoor particulate pollution in fitness centres with emphasis on ultrafine particles. (February 2018)
- Record Type:
- Journal Article
- Title:
- Indoor particulate pollution in fitness centres with emphasis on ultrafine particles. (February 2018)
- Main Title:
- Indoor particulate pollution in fitness centres with emphasis on ultrafine particles
- Authors:
- Slezakova, Klara
Peixoto, Cátia
Oliveira, Marta
Delerue-Matos, Cristina
Pereira, Maria do Carmo
Morais, Simone - Abstract:
- Abstract: Fitness centres (FC) represent a unique indoor microenvironment. Exercising on regular basis provides countless health benefits and improves overall well-being, but if these facilities have poor indoor air quality, the respective exercisers might be subjected to some adverse risks. Considering the limited existent data, this work aimed to evaluate particulate pollution (PM10, PM2.5, and ultrafine particles – UFP) in indoor air of FC and to estimate the respective risks for occupants (both staff and exercising subjects). Sampling was conducted during 40 consecutive days of May–June 2014 in general fitness areas, studios and classrooms (for group activities) of four different fitness centres (FC1–FC4) situated within Oporto metropolitan area, Portugal. The results showed that across the four FC, PM10 ranged between 5 and 1080 μg m −3 with median concentrations (15–43 μg m −3 ) fulfilling the limit (50 μg m −3 ) of Portuguese legislation in all FC. PM2.5 (medians 5–37 μg m −3 ; range 5–777 μg m −3 ) exceeded thresholds of 25 μg m −3 at some FC, indicating potential risks for the respective occupants; naturally ventilated FC exhibited significantly higher PM ranges ( p < 0.05). Similarly, UFPs (range 0.5–88.6 × 10 3 # cm −3 ) median concentrations were higher (2–3 times) at FC without controlled ventilation systems. UFP were approximately twice higher ( p < 0.05) during the occupied periods (mean of 9.7 × 10 3 vs . 4.8 × 10 3 # cm −3 ) with larger temporal variationsAbstract: Fitness centres (FC) represent a unique indoor microenvironment. Exercising on regular basis provides countless health benefits and improves overall well-being, but if these facilities have poor indoor air quality, the respective exercisers might be subjected to some adverse risks. Considering the limited existent data, this work aimed to evaluate particulate pollution (PM10, PM2.5, and ultrafine particles – UFP) in indoor air of FC and to estimate the respective risks for occupants (both staff and exercising subjects). Sampling was conducted during 40 consecutive days of May–June 2014 in general fitness areas, studios and classrooms (for group activities) of four different fitness centres (FC1–FC4) situated within Oporto metropolitan area, Portugal. The results showed that across the four FC, PM10 ranged between 5 and 1080 μg m −3 with median concentrations (15–43 μg m −3 ) fulfilling the limit (50 μg m −3 ) of Portuguese legislation in all FC. PM2.5 (medians 5–37 μg m −3 ; range 5–777 μg m −3 ) exceeded thresholds of 25 μg m −3 at some FC, indicating potential risks for the respective occupants; naturally ventilated FC exhibited significantly higher PM ranges ( p < 0.05). Similarly, UFPs (range 0.5–88.6 × 10 3 # cm −3 ) median concentrations were higher (2–3 times) at FC without controlled ventilation systems. UFP were approximately twice higher ( p < 0.05) during the occupied periods (mean of 9.7 × 10 3 vs . 4.8 × 10 3 # cm −3 ) with larger temporal variations of UFP levels observed in general fitness areas than in classrooms and studios. Cardio activities (conducted in studios and classrooms) led to approximately twice the UFPs intakes than other types of exercising. These results indicate that even short-term physical activity (or more specifically its intensity) might strongly influence the daily inhalation dose. Finally, women exhibited 1.2 times higher UFPs intake than men thus suggesting the need for future gender-specific studies assessing UFP exposure. Graphical abstract: Image 1 Highlights: PM10, PM2.5 and UFP were assessed in indoor air of four fitness centres. PM10 levels fulfilled legislative limit in all FC, PM2.5 was exceeded in 50% of FC. UFP (0.5–88.6 × 10 3 # cm −3 ) were 2–3 times higher at FC with natural ventilation. UFP and PM were significantly higher during the occupied periods. Cardio activities led to twice higher UFP intakes than other types of exercising. Abstract : This work fills a gap providing new information on ultrafine particle number levels in indoor air of fitness centres and the respective inhalation doses considering different genders and various scenarios of fitness activity (cardio and holistic classes). … (more)
- Is Part Of:
- Environmental pollution. Volume 233(2018)
- Journal:
- Environmental pollution
- Issue:
- Volume 233(2018)
- Issue Display:
- Volume 233, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 233
- Issue:
- 2018
- Issue Sort Value:
- 2018-0233-2018-0000
- Page Start:
- 180
- Page End:
- 193
- Publication Date:
- 2018-02
- Subjects:
- Indoor air -- Particulate matter (PM) -- Ultrafine particles (UFPs) -- Fitness centers -- Inhalation intake
Pollution -- Periodicals
Pollution -- Environmental aspects -- Periodicals
Environmental Pollution -- Periodicals
Pollution -- Périodiques
Pollution -- Aspect de l'environnement -- Périodiques
Pollution -- Effets physiologiques -- Périodiques
Pollution
Pollution -- Environmental aspects
Periodicals
Electronic journals
363.73 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02697491 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.envpol.2017.10.050 ↗
- Languages:
- English
- ISSNs:
- 0269-7491
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3791.539000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19103.xml