Nondimensional convection numbers modeling thermally stratified storage tanks: Richardson's number and hot-water tanks. (October 2021)
- Record Type:
- Journal Article
- Title:
- Nondimensional convection numbers modeling thermally stratified storage tanks: Richardson's number and hot-water tanks. (October 2021)
- Main Title:
- Nondimensional convection numbers modeling thermally stratified storage tanks: Richardson's number and hot-water tanks
- Authors:
- Rendall, Joseph
Abu-Heiba, Ahmad
Gluesenkamp, Kyle
Nawaz, Kashif
Worek, William
Elatar, Ahmed - Abstract:
- Abstract: Thermally stratified storage tank studies have spanned over 50 years to increase the thermal storage efficiency and accurate prediction of the outlet temperature particularly for solar applications. The studies have reviewed and modeled the jet and plume flow phenomena inside the tank due to the inlet mixing and stratification level. Kelvin–Helmholtz and Rayleigh–Taylor instabilities are the major drivers of the mixing in these tanks. Momentum jets deflecting off walls at the bottom of the tank also create significant mixing. Reviewing Richardson models shows that the categorization was based on the range of Reynolds numbers at the inlet. Unfortunately, the use of superficial velocity in calculating the Richardson number results in critical values in the literature ranging from below 0.25 to 100. The most used length scale associated with these flows is an inertial scale based on the tank height or diameter although the mixing can occur at a relatively smaller scale. The various inlet devices and a large span of flow rates experienced in thermally stratified storage tanks requisite the use of the Reynolds number in combination with a convection number for accurate one dimensional models that predict performance over the long-term. The evaluation of peak shifting of electric loads leveraging renewable sources for applications, including residential hot-water tanks, commercial water tanks, and large-scale chilled water storage tanks, require these models. This paperAbstract: Thermally stratified storage tank studies have spanned over 50 years to increase the thermal storage efficiency and accurate prediction of the outlet temperature particularly for solar applications. The studies have reviewed and modeled the jet and plume flow phenomena inside the tank due to the inlet mixing and stratification level. Kelvin–Helmholtz and Rayleigh–Taylor instabilities are the major drivers of the mixing in these tanks. Momentum jets deflecting off walls at the bottom of the tank also create significant mixing. Reviewing Richardson models shows that the categorization was based on the range of Reynolds numbers at the inlet. Unfortunately, the use of superficial velocity in calculating the Richardson number results in critical values in the literature ranging from below 0.25 to 100. The most used length scale associated with these flows is an inertial scale based on the tank height or diameter although the mixing can occur at a relatively smaller scale. The various inlet devices and a large span of flow rates experienced in thermally stratified storage tanks requisite the use of the Reynolds number in combination with a convection number for accurate one dimensional models that predict performance over the long-term. The evaluation of peak shifting of electric loads leveraging renewable sources for applications, including residential hot-water tanks, commercial water tanks, and large-scale chilled water storage tanks, require these models. This paper is focused on establishing the significance of the convection numbers in conjunction with the Reynolds number for modeling the thermal stratification in storage tanks. Highlights: Reynolds and Richardson numbers characterize mixing in thermally stratified storage tanks. The Richardson number is related to other convection-based nondimensional numbers. The Richardson number has been inconsistently used in tank modeling. At Reynolds number <3, 300, many correlations exist in the literature. Reynolds and Richardson relationship is robust over a range Reynolds number's. … (more)
- Is Part Of:
- Renewable & sustainable energy reviews. Volume 150(2021)
- Journal:
- Renewable & sustainable energy reviews
- Issue:
- Volume 150(2021)
- Issue Display:
- Volume 150, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 150
- Issue:
- 2021
- Issue Sort Value:
- 2021-0150-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10
- Subjects:
- Solar thermal energy storage -- Richardson number -- Reynolds number
Renewable energy sources -- Periodicals
Power resources -- Periodicals
Énergies renouvelables -- Périodiques
Ressources énergétiques -- Périodiques
333.794 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13640321 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/renewable-and-sustainable-energy-reviews ↗ - DOI:
- 10.1016/j.rser.2021.111471 ↗
- Languages:
- English
- ISSNs:
- 1364-0321
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7364.186000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19122.xml