Subjective and objective refractions in eyes with extended‐depth‐of‐focus intraocular lenses using echelette optics: clinical and experimental study. Issue 6 (16th November 2020)
- Record Type:
- Journal Article
- Title:
- Subjective and objective refractions in eyes with extended‐depth‐of‐focus intraocular lenses using echelette optics: clinical and experimental study. Issue 6 (16th November 2020)
- Main Title:
- Subjective and objective refractions in eyes with extended‐depth‐of‐focus intraocular lenses using echelette optics: clinical and experimental study
- Authors:
- Ota, Yuka
Minami, Keiichiro
Oki, Shinichi
Bissen‐Miyajima, Hiroko
Okamoto, Keiichiro
Nakashima, Masaya
Tsubota, Kazuo - Abstract:
- Abstract: Purpose: To evaluate differences in subjective and objective refractions in eyes with extended‐depth‐of‐focus intraocular lenses (EDOF IOLs) using echelette optics, and the effect of the light wavelength used during examinations. Methods: In the prospective study, subjective and objective refractions of 128 eyes of 64 patients were examined 3 months after implantation of the EDOF IOLs (ZXR00V, Johnson & Johnson Surgival Vision). Objective refractions were measured using an autorefractor with a near‐infrared (NIR) light source. Clinical differences in the spherical, cylindrical and spherical equivalent (SE) refractions between the subjective and objective refractions were evaluated. Then, lens powers of monofocal, EDOF and diffractive bifocal IOLs in the use of a 850‐nm light source were measured experimentally for using a lensmeter, and the differences from the monofocal IOLs were calculated. Results: The mean objective refractions were more myopic (p < 0.001) than the subjective refractions; the differences in the spherical, cylindrical and SE refractions were −0.71, −0.26 and −0.84 dioptre, respectively. Experimental investigation resulted that there was the mean difference of 0.83 D with the EDOF from monofocal IOLs at 850 nm, while the difference was −0.20 D with bifocal IOLs. Conclusions: The diffractive EDOF IOLs using echelette gratings inherently induced constant differences in the subjective and objective refractions, which arose from the chromaticAbstract: Purpose: To evaluate differences in subjective and objective refractions in eyes with extended‐depth‐of‐focus intraocular lenses (EDOF IOLs) using echelette optics, and the effect of the light wavelength used during examinations. Methods: In the prospective study, subjective and objective refractions of 128 eyes of 64 patients were examined 3 months after implantation of the EDOF IOLs (ZXR00V, Johnson & Johnson Surgival Vision). Objective refractions were measured using an autorefractor with a near‐infrared (NIR) light source. Clinical differences in the spherical, cylindrical and spherical equivalent (SE) refractions between the subjective and objective refractions were evaluated. Then, lens powers of monofocal, EDOF and diffractive bifocal IOLs in the use of a 850‐nm light source were measured experimentally for using a lensmeter, and the differences from the monofocal IOLs were calculated. Results: The mean objective refractions were more myopic (p < 0.001) than the subjective refractions; the differences in the spherical, cylindrical and SE refractions were −0.71, −0.26 and −0.84 dioptre, respectively. Experimental investigation resulted that there was the mean difference of 0.83 D with the EDOF from monofocal IOLs at 850 nm, while the difference was −0.20 D with bifocal IOLs. Conclusions: The diffractive EDOF IOLs using echelette gratings inherently induced constant differences in the subjective and objective refractions, which arose from the chromatic difference in IOL powers for the visible and NIR lights. … (more)
- Is Part Of:
- Acta ophthalmologica. Volume 99:Issue 6(2021)
- Journal:
- Acta ophthalmologica
- Issue:
- Volume 99:Issue 6(2021)
- Issue Display:
- Volume 99, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 99
- Issue:
- 6
- Issue Sort Value:
- 2021-0099-0006-0000
- Page Start:
- e837
- Page End:
- e843
- Publication Date:
- 2020-11-16
- Subjects:
- chromatic focal difference -- echelette optics -- extended‐depth‐of‐focus intraocular lens -- near infrared -- objective refraction
Ophthalmology -- Periodicals
617.7005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1755-3768 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/aos.14660 ↗
- Languages:
- English
- ISSNs:
- 1755-375X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0641.750500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19081.xml