- Title:
- Dyna-CT-assisted percutaneous microballoon compression for trigeminal neuralgia. (31st July 2013)
- Main Title:
- Dyna-CT-assisted percutaneous microballoon compression for trigeminal neuralgia
- Authors:
- Huo, Xiaochuan
Sun, Xiaoyun
Zhang, Zhenxing
Guo, Wenshi
Guan, Ning
Luo, Junsheng - Abstract:
- Abstract : Background: Percutaneous microballoon compression (PMC) for trigeminal neuralgia (TN) is a well-established technique. However, complications from cannulating the foramen ovale (FO) have been reported because direct puncture of the FO is sometimes difficult. Here we report our experience with Dyna-CT-assisted PMC for TN in cannulating the FO and determining the position and volume of the balloon. Methods: Dyna-CT-assisted PMC was performed for image reconstruction in 16 cases. The optimal working projection was generated and further fluoroscopic data were used to determine the relationship of the needle with the FO during puncture. The balloon position and three-dimensional shape were verified with Dyna-CT during balloon compression and the balloon volume and puncture angle were also calculated. Patients' prognosis is discussed. Results: Dyna-CT allows quick, safe and easy cannulation of the FO. It provided three-dimensional images which were more elaborate than the classic 'pear shape' images for determining correct positioning in 16 cases. The volume of the inflated balloon ranged from 568.2 mm 3 to 891.4 mm 3 (average 769.5 mm 3 ). The angle of introducing the cannula ranged from 15.32° to 35.48° rotation to the midline (average 25.18°) and 38.47°–51.89° angulation to the Reid line (average 46.17°). All the patients were pain-free after PMC. Four patients had resolvable masseter weakness and fine touch loss. No recurrence of TN was reported on follow-up.Abstract : Background: Percutaneous microballoon compression (PMC) for trigeminal neuralgia (TN) is a well-established technique. However, complications from cannulating the foramen ovale (FO) have been reported because direct puncture of the FO is sometimes difficult. Here we report our experience with Dyna-CT-assisted PMC for TN in cannulating the FO and determining the position and volume of the balloon. Methods: Dyna-CT-assisted PMC was performed for image reconstruction in 16 cases. The optimal working projection was generated and further fluoroscopic data were used to determine the relationship of the needle with the FO during puncture. The balloon position and three-dimensional shape were verified with Dyna-CT during balloon compression and the balloon volume and puncture angle were also calculated. Patients' prognosis is discussed. Results: Dyna-CT allows quick, safe and easy cannulation of the FO. It provided three-dimensional images which were more elaborate than the classic 'pear shape' images for determining correct positioning in 16 cases. The volume of the inflated balloon ranged from 568.2 mm 3 to 891.4 mm 3 (average 769.5 mm 3 ). The angle of introducing the cannula ranged from 15.32° to 35.48° rotation to the midline (average 25.18°) and 38.47°–51.89° angulation to the Reid line (average 46.17°). All the patients were pain-free after PMC. Four patients had resolvable masseter weakness and fine touch loss. No recurrence of TN was reported on follow-up. Conclusions: Dyna-CT performed by digital subtraction angiography assists PMC in three ways: (1) the FO can be better visualized independent of the patient's position; (2) needle correction or insertion can be performed much more easily because of the direct fluoroscopic control; and (3) the needle position, balloon position, balloon configuration and the volume of the inflated balloon is more reliably determined. The use of Dyna-CT-assisted PMC has a low incidence of complications and a good prognosis. … (more)
- Is Part Of:
- Journal of neurointerventional surgery. Volume 6:Number 7(2014)
- Journal:
- Journal of neurointerventional surgery
- Issue:
- Volume 6:Number 7(2014)
- Issue Display:
- Volume 6, Issue 7 (2014)
- Year:
- 2014
- Volume:
- 6
- Issue:
- 7
- Issue Sort Value:
- 2014-0006-0007-0000
- Page Start:
- 521
- Page End:
- 526
- Publication Date:
- 2013-07-31
- Subjects:
- Cranial nerve -- CT -- Balloon -- Technique
Nervous system -- Surgery -- Periodicals
Cerebrovascular disease -- Surgery -- Periodicals
617.48 - Journal URLs:
- http://www.bmj.com/archive ↗
http://jnis.bmj.com/ ↗ - DOI:
- 10.1136/neurintsurg-2013-010676 ↗
- Languages:
- English
- ISSNs:
- 1759-8478
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19067.xml