Assessment of the stability of citrate-buffered flucloxacillin for injection when stored in two commercially available ambulatory elastomeric devices: INfusor LV (Baxter) and Accufuser (Woo Young Medical): a study compliant with the NHS Yellow Cover Document (YCD) requirements. Issue 2 (18th September 2018)
- Record Type:
- Journal Article
- Title:
- Assessment of the stability of citrate-buffered flucloxacillin for injection when stored in two commercially available ambulatory elastomeric devices: INfusor LV (Baxter) and Accufuser (Woo Young Medical): a study compliant with the NHS Yellow Cover Document (YCD) requirements. Issue 2 (18th September 2018)
- Main Title:
- Assessment of the stability of citrate-buffered flucloxacillin for injection when stored in two commercially available ambulatory elastomeric devices: INfusor LV (Baxter) and Accufuser (Woo Young Medical): a study compliant with the NHS Yellow Cover Document (YCD) requirements
- Authors:
- Allwood, Michael Charles
Stonkute, Donata
Wallace, Andrew
Wilkinson, Alan-Shaun
Hills, Tim
Jamieson, Conor - Other Names:
- author non-byline.
Gilchrist Mark author non-byline.
Santillo Mark author non-byline.
Seaton Andrew author non-byline. - Abstract:
- Abstract : Objectives: To investigate the effect of pH and buffers on the degradation rate of flucloxacillin and to determine if flucloxacillin can be stabilised using a buffered diluent for up to 14 days when stored at 2°C–8°C including a 24-hour infusion period at 32°C in two elastomeric devices (Accufuser and INfusor LV) filled to 240 mL. Testing as per the NHS Pharmaceutical Quality Assurance Committee Yellow Cover Document (YCD) requirements. Methods: A validated stability indicating high-performance liquid chromatography method was used for assessing the stability of flucloxacillin diluted in 0.3% w/v citrate-buffered saline pH 7.0 when stored at 2°C–8°C in two ambulatory devices (Accufuser and INfusor LV). Flucloxacillin at 10 and 50 mg/mL diluted in 0.3% w/v citrate-buffered saline pH 7.0 to a final volume of 240 mL and stored at 2°C–8°C, including 24 hours at 32°C, was tested from two batches in replicate (n=3) at five time points for up to 14 days according to the requirements of the YCD. Results: Greater than 95% of the zero-time concentration of flucloxacillin at 10 and 50 mg/mL remained when stored at 2°C–8°C after 14 days including 24 hours at 32°C in both Accufuser and INfusor LV devices. Conclusions: Flucloxacillin sodium stability was improved, and complied with UK national standards, by using a diluent of 0.3% w/v citrate-buffered saline pH 7 in both Accufuser and INfusor LV ambulatory devices when filled to 240 mL. The data support assigning a shelf-lifeAbstract : Objectives: To investigate the effect of pH and buffers on the degradation rate of flucloxacillin and to determine if flucloxacillin can be stabilised using a buffered diluent for up to 14 days when stored at 2°C–8°C including a 24-hour infusion period at 32°C in two elastomeric devices (Accufuser and INfusor LV) filled to 240 mL. Testing as per the NHS Pharmaceutical Quality Assurance Committee Yellow Cover Document (YCD) requirements. Methods: A validated stability indicating high-performance liquid chromatography method was used for assessing the stability of flucloxacillin diluted in 0.3% w/v citrate-buffered saline pH 7.0 when stored at 2°C–8°C in two ambulatory devices (Accufuser and INfusor LV). Flucloxacillin at 10 and 50 mg/mL diluted in 0.3% w/v citrate-buffered saline pH 7.0 to a final volume of 240 mL and stored at 2°C–8°C, including 24 hours at 32°C, was tested from two batches in replicate (n=3) at five time points for up to 14 days according to the requirements of the YCD. Results: Greater than 95% of the zero-time concentration of flucloxacillin at 10 and 50 mg/mL remained when stored at 2°C–8°C after 14 days including 24 hours at 32°C in both Accufuser and INfusor LV devices. Conclusions: Flucloxacillin sodium stability was improved, and complied with UK national standards, by using a diluent of 0.3% w/v citrate-buffered saline pH 7 in both Accufuser and INfusor LV ambulatory devices when filled to 240 mL. The data support assigning a shelf-life of up to 14 days (13 days stored at 2°C–8°C and 24 hours at 32°C). Flucloxacillin may now be used appropriately as a continuous 24-hour infusion in outpatient parenteral antimicrobial therapy services, providing further opportunity to avoid or shorten patient hospital stays, as well as support ideal antimicrobial stewardship principles. … (more)
- Is Part Of:
- European journal of hospital pharmacy. Volume 27:Issue 2(2020)
- Journal:
- European journal of hospital pharmacy
- Issue:
- Volume 27:Issue 2(2020)
- Issue Display:
- Volume 27, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 27
- Issue:
- 2
- Issue Sort Value:
- 2020-0027-0002-0000
- Page Start:
- 90
- Page End:
- 94
- Publication Date:
- 2018-09-18
- Subjects:
- flucloxacillin -- stability -- elastomeric pump -- ambulatory -- antimicrobial stewardship -- outpatient parenteral antimicrobial chemotherapy
Pharmacy -- Periodicals
Hospital pharmacies -- Periodicals
615.1 - Journal URLs:
- http://www.bmj.com/archive ↗
http://ejhp.bmj.com/ ↗ - DOI:
- 10.1136/ejhpharm-2018-001515 ↗
- Languages:
- English
- ISSNs:
- 2047-9956
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 19005.xml