Assessment of tolerance, safety and efficacy of ambulatory oesophageal ph monitoring using the catheter-free bravo system in a scottish population. (13th March 2011)
- Record Type:
- Journal Article
- Title:
- Assessment of tolerance, safety and efficacy of ambulatory oesophageal ph monitoring using the catheter-free bravo system in a scottish population. (13th March 2011)
- Main Title:
- Assessment of tolerance, safety and efficacy of ambulatory oesophageal ph monitoring using the catheter-free bravo system in a scottish population
- Authors:
- Macdonald, J
Porter-Ritchie, V
Mackie, B
McNamara, D - Abstract:
- Abstract : Introduction: Limitations of catheter-based oesophageal pH monitoring are discomfort, inconvenience and interference with normal daily activities. The wireless Bravo pH system is an alternative method, using catheter-free technology to assess oesophageal pH exposure. This study assesses the tolerance, safety and efficacy of the Bravo pH system in a Scottish population and compares the results with previously published data. Methods: Patients with symptoms of gastro-oesophageal reflux disease (GORD) with an indication for 24 h pH assessment were recruited. The wireless Medtronic Bravo pH capsule was placed 6 cm above the squamocolumnar junction using endoscopic measurement. After 48 h, studies were uploaded from the receiver and analysed. Completion (48 h recordings), concordance and complication rates were evaluated. Results: A total of 40 patients were recruited; 18 (45%) men, mean age 52±11 years. 13 (33%) subjects were possible surgical candidates and 5 (13%) had GORD symptoms postsurgery. Capsules were successfully placed in all cases (100%) and 27 (68%) patients required no sedation. In all 37 of 40 studies were complete (93%). Complications occurred in 2 (5%) cases; both complained of chest pain, repeat endoscopy was normal in one case and the other revealed a small oesophageal ulcer that did not require intervention. In all 31 (78%) of studies were positive with overall 24 h pH of >4.2%. Comparison between 24 and 48 h data showed discordance in 5 (14%)Abstract : Introduction: Limitations of catheter-based oesophageal pH monitoring are discomfort, inconvenience and interference with normal daily activities. The wireless Bravo pH system is an alternative method, using catheter-free technology to assess oesophageal pH exposure. This study assesses the tolerance, safety and efficacy of the Bravo pH system in a Scottish population and compares the results with previously published data. Methods: Patients with symptoms of gastro-oesophageal reflux disease (GORD) with an indication for 24 h pH assessment were recruited. The wireless Medtronic Bravo pH capsule was placed 6 cm above the squamocolumnar junction using endoscopic measurement. After 48 h, studies were uploaded from the receiver and analysed. Completion (48 h recordings), concordance and complication rates were evaluated. Results: A total of 40 patients were recruited; 18 (45%) men, mean age 52±11 years. 13 (33%) subjects were possible surgical candidates and 5 (13%) had GORD symptoms postsurgery. Capsules were successfully placed in all cases (100%) and 27 (68%) patients required no sedation. In all 37 of 40 studies were complete (93%). Complications occurred in 2 (5%) cases; both complained of chest pain, repeat endoscopy was normal in one case and the other revealed a small oesophageal ulcer that did not require intervention. In all 31 (78%) of studies were positive with overall 24 h pH of >4.2%. Comparison between 24 and 48 h data showed discordance in 5 (14%) studies, in all cases day 1 readings were within normal limits and day 2 consistent with a diagnosis of GORD. Conclusion: This study shows that ambulatory wireless Bravo pH tests are safe and effective in this population and results compare favourably with reported studies. Of note is the beneficial effect of 48 h readings, resulting in an additional positive diagnosis in 14% of the patient population. … (more)
- Is Part Of:
- Gut. Volume 60:(2011)Supplement 1
- Journal:
- Gut
- Issue:
- Volume 60:(2011)Supplement 1
- Issue Display:
- Volume 60, Issue 1 (2011)
- Year:
- 2011
- Volume:
- 60
- Issue:
- 1
- Issue Sort Value:
- 2011-0060-0001-0000
- Page Start:
- A182
- Page End:
- A183
- Publication Date:
- 2011-03-13
- Subjects:
- Bravo -- pH monitoring -- wireless pH monitoring
Gastroenterology -- Periodicals
616.33 - Journal URLs:
- http://gut.bmjjournals.com ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/gut.2011.239301.388 ↗
- Languages:
- English
- ISSNs:
- 0017-5749
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19030.xml