Increasing reflux study duration progressively improves diagnostic consistency: a prospective study with 96 h wireless pH recordings. (13th March 2011)
- Record Type:
- Journal Article
- Title:
- Increasing reflux study duration progressively improves diagnostic consistency: a prospective study with 96 h wireless pH recordings. (13th March 2011)
- Main Title:
- Increasing reflux study duration progressively improves diagnostic consistency: a prospective study with 96 h wireless pH recordings
- Authors:
- Fox, M R
Sweis, R
Menne, D
Anggiansah, A
Wong, T - Abstract:
- Abstract : Introduction: Previous studies suggest that prolonged ambulatory reflux monitoring can improve measurement consistency; however, previous reports were not analysed appropriately or adequately powered to determine the impact on key clinical parameters. The aim of this study was to assess measurement consistency for acid exposure time (AET) and symptom association with reflux events used to establish the diagnosis of GORD. Methods: Acid reflux (pH) and symptom data were acquired by prolonged, 4 day, wireless pH recording (Bravo, Given Imaging). 163 consecutive patients presenting with predominantly typical reflux symptoms (heartburn, regurgitation) studied 2006–2009 with a record duration of >3.7 days were studied (636 days). Data were exported in XML format, redundant symptom markers were removed in one pass with reflux detection. A cross-validation procedure assessed measurement variability (standard deviation (SD)) and diagnostic consistency of AET, symptom index (SI) and symptom association probability (SAP). The 4-day records were divided into 1-day sections and re-assembled as all possible subsets. Index parameters were computed for all subsets and labelled with a sequence identifier in the database. Bias due to self-referential comparisons was excluded (i.e., day 1 was not compared with day 123) and, also, no comparisons with 4-day results are given. Standard diagnostic thresholds were applied. In addition, the effect of varying threshold pH value used forAbstract : Introduction: Previous studies suggest that prolonged ambulatory reflux monitoring can improve measurement consistency; however, previous reports were not analysed appropriately or adequately powered to determine the impact on key clinical parameters. The aim of this study was to assess measurement consistency for acid exposure time (AET) and symptom association with reflux events used to establish the diagnosis of GORD. Methods: Acid reflux (pH) and symptom data were acquired by prolonged, 4 day, wireless pH recording (Bravo, Given Imaging). 163 consecutive patients presenting with predominantly typical reflux symptoms (heartburn, regurgitation) studied 2006–2009 with a record duration of >3.7 days were studied (636 days). Data were exported in XML format, redundant symptom markers were removed in one pass with reflux detection. A cross-validation procedure assessed measurement variability (standard deviation (SD)) and diagnostic consistency of AET, symptom index (SI) and symptom association probability (SAP). The 4-day records were divided into 1-day sections and re-assembled as all possible subsets. Index parameters were computed for all subsets and labelled with a sequence identifier in the database. Bias due to self-referential comparisons was excluded (i.e., day 1 was not compared with day 123) and, also, no comparisons with 4-day results are given. Standard diagnostic thresholds were applied. In addition, the effect of varying threshold pH value used for reflux detection on diagnostic consistency was assessed. Results: Measurement variability: There was no change in AET or SI over time; however, SAP increased progressively with study duration. Standard deviation (SD) was higher for 1-day than 3-day records for AET (+50% (confidence interval (CI): 10%…120%)) and SI (+100% (CI 120%…270%)) with no important difference across the observed range. Results for 2 days were intermediate. Similar findings were present for SAP (1 day vs 3 days at 95% SAP (+100% (CI 10%…700%); however, for this parameter measurement variability increased exponentially as SAP approached 100%. Diagnosis: Consistency for GORD diagnosis increased with study duration (table 1 ) for all parameters studied. Conclusion: Increasing the duration of reflux studies progressively improves diagnostic consistency for GORD based on both AET and reflux-symptom association analysis independent of diagnostic threshold applied. … (more)
- Is Part Of:
- Gut. Volume 60:(2011)Supplement 1
- Journal:
- Gut
- Issue:
- Volume 60:(2011)Supplement 1
- Issue Display:
- Volume 60, Issue 1 (2011)
- Year:
- 2011
- Volume:
- 60
- Issue:
- 1
- Issue Sort Value:
- 2011-0060-0001-0000
- Page Start:
- A23
- Page End:
- A24
- Publication Date:
- 2011-03-13
- Subjects:
- oesophageal acid exposure -- pH monitoring -- reflux -- symptom association probability -- symptom index
Gastroenterology -- Periodicals
616.33 - Journal URLs:
- http://gut.bmjjournals.com ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/gut.2011.239301.48 ↗
- Languages:
- English
- ISSNs:
- 0017-5749
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 19029.xml