How direct measurements of worker eyes with a Scheimpflug camera can affect lensdose coefficients in interventional radiology. (30th September 2021)
- Record Type:
- Journal Article
- Title:
- How direct measurements of worker eyes with a Scheimpflug camera can affect lensdose coefficients in interventional radiology. (30th September 2021)
- Main Title:
- How direct measurements of worker eyes with a Scheimpflug camera can affect lensdose coefficients in interventional radiology
- Authors:
- Iori, Mauro
Isolan, Lorenzo
Piergallini, Lorenzo
Chendi, Agnese
Lasagni, Lorenzo
Cucchi, Giorgio
Bertolini, Marco
Fioroni, Federica
Piccagli, Vando
Moramarco, Antonio
Romano, Maria Grazia
Fontana, Luigi
Strigari, Lidia
D'Alessio, Daniela
Bruzzaniti, Vicente
Sgura, Antonella
Udroiu, Ion
Rosi, Antonella
Grande, Sveva
Palma, Alessandra
Giliberti, Claudia
Sumini, Marco - Abstract:
- Abstract: The 2013/59/Euratom Directive reduced the occupational exposure limits for the lens. Since it has become crucial to estimate the dose absorbed by the lens, we have studied the individual variability of exposed workers' ocular conformations with respect to the data estimated from their personal dosimetry. The anterior eye conformations of 45 exposed workers were acquired using Scheimpflug imaging and classified according to their sight conditions (emmetropia, myopia or hypermetropia). Three eye models were computed, with two lens reconstructions, and implemented in an interventional radiology scenario using Monte Carlo code. The models were dosimetrically analysed by simulating setup A, a theoretical monoenergetic and isotropic photon source (10–150 keV) and setup B, a more realistic interventional setting with an angiographic x-ray unit (50, 75, 100 kV peak). Scheimpflug imaging provided an average anterior chamber depth of (6.4 ± 0.5) mm and a lens depth of (3.9 ± 0.3) mm, together with a reconstructed equatorial lens length of (7.1–10.1) mm. Using these data for model reconstruction, dose coefficients (DCs) were simulated for all ocular structures. Regardless of the eye model used, the DCs showed a similar trend with radiation energy, which highlighted that for the same energy and setup, no significant dependence on ocular morphology and workers' visual conditions was observed. The maximum difference obtained did not exceed 1% for all eye models or structuresAbstract: The 2013/59/Euratom Directive reduced the occupational exposure limits for the lens. Since it has become crucial to estimate the dose absorbed by the lens, we have studied the individual variability of exposed workers' ocular conformations with respect to the data estimated from their personal dosimetry. The anterior eye conformations of 45 exposed workers were acquired using Scheimpflug imaging and classified according to their sight conditions (emmetropia, myopia or hypermetropia). Three eye models were computed, with two lens reconstructions, and implemented in an interventional radiology scenario using Monte Carlo code. The models were dosimetrically analysed by simulating setup A, a theoretical monoenergetic and isotropic photon source (10–150 keV) and setup B, a more realistic interventional setting with an angiographic x-ray unit (50, 75, 100 kV peak). Scheimpflug imaging provided an average anterior chamber depth of (6.4 ± 0.5) mm and a lens depth of (3.9 ± 0.3) mm, together with a reconstructed equatorial lens length of (7.1–10.1) mm. Using these data for model reconstruction, dose coefficients (DCs) were simulated for all ocular structures. Regardless of the eye model used, the DCs showed a similar trend with radiation energy, which highlighted that for the same energy and setup, no significant dependence on ocular morphology and workers' visual conditions was observed. The maximum difference obtained did not exceed 1% for all eye models or structures analysed. Therefore, the individual variabilities of worker ocular anatomy do not require any additional correction, compared to the personal dosimetry data measured with a dedicated lens dosimeter. To estimate the dose absorbed by the other eye structures, it is, instead, essential to know the spectrum of the source that has generated the irradiation, since there are differences between monoenergetic sources and more realistic angiographic units. … (more)
- Is Part Of:
- Journal of radiological protection. Volume 41:Number 4(2021)
- Journal:
- Journal of radiological protection
- Issue:
- Volume 41:Number 4(2021)
- Issue Display:
- Volume 41, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 41
- Issue:
- 4
- Issue Sort Value:
- 2021-0041-0004-0000
- Page Start:
- 689
- Page End:
- 706
- Publication Date:
- 2021-09-30
- Subjects:
- eye models -- lens -- Scheimpflug chamber -- Monte Carlo -- interventional radiology -- radiation protection
Radiation -- Safety measures -- Periodicals
Health Physics -- Periodicals
Radiation Monitoring -- Periodicals
Radiation Protection -- Periodicals
Rayonnement -- Sécurité -- Mesures -- Périodiques
Electronic journals
Fulltext
Internet Resource
Periodical
363.179905 - Journal URLs:
- http://www.iop.org/EJ/journal/JRP ↗
http://iopscience.iop.org/0952-4746/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1361-6498/abf56f ↗
- Languages:
- English
- ISSNs:
- 0952-4746
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18994.xml